Theoretical model for response calculation of electret ionisation chambers for radon dosimetry

被引:4
|
作者
Kunzmann, S
Dorschel, B
机构
[1] Dresden University of Technology, Physics Department, Inst. of Radiat. Protection Physics
关键词
D O I
10.1093/oxfordjournals.rpd.a031538
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The application of electret chambers for radon measurements requires the exact determination of their response. Therefore, a theoretical model has been established in order to calculate the radon response for any electret ionisation chamber and to quantify the physical processes responsible for the decrease of response at lower electret voltages. Moreover, a deeper understanding of the processes inside the chamber is helpful for the discussion of possible uncertainties of measurements. The model is based on a numerical calculation of the electric field inside the chamber and in the electret reader arrangement. It is shown that the main reasons for the decrease of the radon response with decreasing electret voltage are the growing recombination loss due to a lower field strength and the influence of changes in the electret surface charge distribution on the reader characteristics. The results of the calculation are compared with experimental data.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 50 条
  • [1] Optimisation of electret ionisation chambers for radon dosimetry on the basis of a theoretical model
    Kunzmann, S
    Dorschel, B
    Zeiske, U
    RADIATION PROTECTION DOSIMETRY, 1996, 63 (04) : 269 - 274
  • [2] Studies on the practical application of electret ionisation chambers for radon dosimetry under special conditions
    Kunzmann, S
    Dorschel, B
    Havlik, F
    Nikodemova, D
    RADIATION PROTECTION DOSIMETRY, 1996, 63 (04) : 275 - 279
  • [3] Diamond ionisation chambers for dosimetry
    Brambilla, A
    Bergonzo, P
    Foulon, F
    Jany, C
    Pochet, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 446 - 449
  • [4] Theoretical calculation of SSNTD response for radon measurements and optimum diffusion chambers dimensions
    Mansy, M
    Sharaf, MA
    Eissa, HM
    El-Kamees, SU
    Abo-Elmagd, M
    RADIATION MEASUREMENTS, 2006, 41 (02) : 222 - 228
  • [5] Radon measurement in Canada with electret ion chambers
    Chen, Jing
    HEALTH PHYSICS, 2007, 93 (02): : 161 - 164
  • [6] Theoretical calculation on CR-39 response for radon measurements and optimum diffusion chambers dimensions
    Askari, H. R.
    Ghandi, Kh.
    Rahimi, M.
    Negarestani, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 596 (03): : 368 - 383
  • [7] Studies on the surface charge distribution of radon exposed electrets within an electret ionisation chamber
    Kunzmann, S
    Dorschel, B
    Hase, K
    Zeiske, U
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 367 - 370
  • [8] PROPERTIES OF ELECTRET IONIZATION CHAMBERS INTENDED FOR ROUTINE DOSIMETRY IN PHOTON RADIATION-FIELDS
    DORSCHEL, B
    PRETZSCH, G
    KERNENERGIE, 1985, 28 (09): : 387 - 390
  • [9] Theoretical calculation of radon emanation fraction
    Stajic, J. M.
    Nikezic, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 336 : 19 - 25
  • [10] Response comparisons of electret ion chambers, LiF TLD, and HPIC
    Hobbs, T
    Kotrappa, P
    Tracy, J
    Biss, B
    RADIATION PROTECTION DOSIMETRY, 1996, 63 (03) : 181 - 188