Two Cases of Pseudoelevation of Plasma D-Dimer Levels

被引:4
作者
Zhang, Lihong [1 ]
Bao, Guoxiang [1 ]
Zheng, Zhuan [1 ]
机构
[1] Shaoxing Peoples Hosp, Dept Clin Lab Ctr, Shaoxing, Peoples R China
关键词
D-dimer; pseudoelevation; heterophilic antibody; INTERFERENCE;
D O I
10.7754/Clin.Lab.2021.210203
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: D-dimer is a molecular marker of fibrin degradation and fibrinolytic system activation and is an effective indicator for early diagnosis of thrombotic diseases, monitoring of thrombolytic therapy, and efficacy evaluation; therefore, the accuracy of D-dimer test results is of great significance to the diagnosis and treatment of diseases in clinical practice. Methods: This paper reports two cases of pseudoelevation of plasma D-dimer levels by different test systems. Results: In case 1, the abnormal increases in the results of the ACL TOP 700 analyzer were considered to be the pseudoelevation caused by interferences, and the abnormal increases in the STA-R Max results were considered to be the pseudoelevation caused by interferences in case 2. Conclusions: Laboratories should be equipped with two different brands of test systems and reagents to identify suspicious test results in a timely manner and avoid adverse events.
引用
收藏
页码:2145 / 2147
页数:3
相关论文
共 10 条
[1]   Pulmonary Embolism and Increased Levels of D-Dimer in Patients with Coronavirus Disease [J].
Chan, Kok Hoe ;
Slim, Jihad ;
Shaaban, Hamid S. .
EMERGING INFECTIOUS DISEASES, 2020, 26 (10) :2532-2533
[2]   Correlation Between D-Dimer Level and Deep Venous Thrombosis in Patients With Acute Spinal Cord Injuries [J].
Cho, Jang Hyuk ;
Kim, Jong Bum ;
Lee, Dong Gyu .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2020, 99 (07) :613-616
[3]   Value of TAT and PIC with D-dimer for cancer patients with metastasis [J].
Cui, Chanjuan ;
Gao, Jia ;
Li, Jia ;
Yu, Mengyao ;
Zhang, Hao ;
Cui, Wei .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2020, 42 (04) :387-393
[4]   Interference from heterophilic antibodies in D-dimer assessment. A case report [J].
Lippi, Giuseppe ;
Ippolito, Luigi ;
Tondelli, Maria Teresa ;
Favaloro, Emmanuel J. .
BLOOD COAGULATION & FIBRINOLYSIS, 2014, 25 (03) :277-279
[5]   D-dimer plasmatic levels as a marker for diagnosis and prognosis of hepatocellular carcinoma patients with portal vein thrombosis [J].
Malaguarnera, Michele ;
Latteri, Saverio ;
Bertino, Gaetano ;
Madeddu, Roberto ;
Catania, Vito Emanuele ;
Curro, Giuseppe ;
Borzi, Antonio Maria ;
Drago, Filippo ;
Malaguarnera, Giulia .
CLINICAL AND EXPERIMENTAL GASTROENTEROLOGY, 2018, 11 :373-380
[6]   Interference of icterus on plasma D-dimer levels measured using immunoturbidimetric assays [J].
Mastella, Aline K. ;
de Carvalho, Jose A. M. ;
Stein, Carolina S. ;
Bochi, Guilherme V. ;
Moresco, Rafael N. .
BLOOD COAGULATION & FIBRINOLYSIS, 2021, 32 (02) :162-163
[7]   D-dimer and its relationship to fibrinogen/fibrin degradation products (FDPs) in disorders associated with activation of coagulation or fibrinolytic systems [J].
Moresco, RN ;
Vargas, LCR ;
Voegeli, CF ;
Santos, RCV .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2003, 17 (03) :77-79
[8]   Multiplex cytokine analyses in patients with rheumatoid arthritis require use of agents blocking heterophilic antibody activity [J].
Olsson, P. ;
Theander, E. ;
Bergstrom, U. ;
Jovinge, S. ;
Jacobsson, L. T. H. ;
Turesson, C. .
SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2017, 46 (01) :1-10
[9]  
Watanabe A, 2020, PANCREAS, V49, pE36, DOI 10.1097/MPA.0000000000001537
[10]   What makes D-dimer assays suspicious-heterophilic antibodies? [J].
Wu, Ying ;
Xiao, Ying-Xiu ;
Huang, Teng-Yi ;
Zhang, Xian-Yan ;
Zhou, Huan-Bing ;
Zhang, Xue-Xuan ;
Wu, Ying-E .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2019, 33 (02)