Preconcentration and electroanalysis of silver species at polypyrrole film modified glassy carbon electrodes

被引:58
作者
Song, FY
Shiu, KK
机构
[1] Kong Kong Baptist Univ, Dept Chem, Kowloon, Hong Kong, Peoples R China
[2] Sichuan Teachers Coll, Dept Chem, Nanchong 637002, Sichuan, Peoples R China
关键词
electroanalysis; polypyrrole; silver determination;
D O I
10.1016/S0022-0728(00)00360-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Silver species can be entrapped in electropolymerized polypyrrole films without deliberate incorporation of chemically active counterions. The effects of polypyrrole coverage and preparation condition, oxidation states, solution composition, pH and the presence of other metal ions on the preconcentration have been investigated. Experimental results showed that the peak current and the integrated charge for incorporated silver species showed good linear concentration dependence in the range of 2-150 muM. The detection limit was estimated to be about 2 etaM (about 0.2 ppm Ag). Most of the metal ions studied, including cobalt, nickel, cadmium, lead, zinc and iron, did not show obvious interference on the determination. Copper and mercury species were also extracted onto polypyrrole film electrodes and caused significant interference in the determination of silver species. The mechanism involved in the preconcentration of silver species at polypyrrole electrodes was explored. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:161 / 170
页数:10
相关论文
共 29 条
[1]  
BECK F, 1992, B ELECTROCHEM, V8, P34
[2]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[3]   POLYPYRROLE AND POLY(N-METHYLPYRROLE) FILMS DOPED WITH KEGGIN-TYPE HETEROPOLYANIONS - PREPARATION AND PROPERTIES [J].
BIDAN, G ;
GENIES, EM ;
LAPKOWSKI, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 251 (02) :297-306
[4]   MECHANISM OF IONIC AND REDOX SENSITIVITY OF P-TYPE CONDUCTING POLYMERS .2. EXPERIMENTAL-STUDY OF POLYPYRROLE [J].
BOBACKA, J ;
GAO, ZQ ;
IVASKA, A ;
LEWENSTAM, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 368 (1-2) :33-41
[5]   Resistance of Ag(I) implanted polypyrrole-based anion ise to cation interferences [J].
Chou, SH ;
Rau, JR ;
Chen, SC .
ELECTROCHIMICA ACTA, 1997, 42 (15) :2313-2317
[6]   A POLYMER ELECTRODE WITH VARIABLE CONDUCTIVITY - POLYPYRROLE [J].
DIAZ, AF ;
CASTILLO, JI .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1980, (09) :397-398
[7]   AN ELECTROCHEMICAL MICROSENSOR FOR CHLORIDE [J].
DONG, SJ ;
CHE, GL .
TALANTA, 1991, 38 (01) :111-114
[8]   A NEW KIND OF CHEMICAL SENSOR BASED ON A CONDUCTING POLYMER FILM [J].
DONG, SJ ;
SUN, ZH ;
LU, ZL .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1988, (15) :993-995
[9]   ELECTROCHEMICAL-BEHAVIOR OF POLYPYRROLE FILM POLYMERIZED IN INDIGO CARMINE SOLUTION [J].
GAO, Z ;
BOBACKA, J ;
LEWENSTAM, A ;
IVASKA, A .
ELECTROCHIMICA ACTA, 1994, 39 (05) :755-762
[10]   PREPARATION AND ELECTROCATALYTIC PROPERTIES OF CONDUCTING FILMS OF POLYPYRROLE CONTAINING PLATINUM MICROPARTICULATES [J].
HOLDCROFT, S ;
FUNT, BL .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 240 (1-2) :89-103