A comparison of X-ray and proton beam low energy secondary electron track structures using the low energy models of Geant4

被引:10
作者
McNamara, Aimee L. [1 ]
Guatelli, Susanna [2 ]
Prokopovich, Dale A. [1 ]
Reinhard, Mark I. [1 ]
Rosenfeld, Anatoly B. [2 ]
机构
[1] Australian Nucl Sci & Technol Org ANSTO, Lucas Heights, NSW, Australia
[2] Univ Wollongong, Ctr Med Radiat Phys CMRP, Wollongong, NSW 2522, Australia
关键词
Ionising radiation; DNA damage; Geant4; track structurethe; RADIATION-THERAPY MRT; DNA-DAMAGE; TOOLKIT; MICRODOSIMETRY; SIMULATION; EXTENSION;
D O I
10.3109/09553002.2011.627975
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: Lethal cell damage by ionising radiation is generally initiated by the formation of complex strand breaks, resulting from ionisation clusters in the DNA molecule. A better understanding of the effect of the distribution of ionisation clusters within the cell and particularly in regard to DNA segments could be beneficial to radiation therapy treatment planning. Low energy X-rays generate an abundance of low energy electrons similar to that associated with MeV protons. The study and comparison of the track structure of photon and proton beams could permit the substitution of photon microbeams for single cell ion irradiations at proton facilities used to predict the relative biological effectiveness (RBE) of charged particle fields. Materials and methods: The track structure of X-ray photons is compared with proton pencil beams in voxels of approximate DNA strand size (2 x 2 x 5 nm). The Very Low Energy extension models of the Monte Carlo simulation toolkit GEometry ANd Tracking 4 (Geant4) is used. Simulations were performed in a water phantom for an X-ray and proton beam of energies 100 keV and 20 MeV, respectively. Results: The track structure of the photon and proton beams are evaluated using the ionisation cluster size distribution as well as the radial dose deposition of the beam. Conclusions: A comparative analysis of the ionisation cluster distribution and radial dose deposition obtained is presented, which suggest that low energy X-rays could produce similar ionisation cluster distributions to MeV protons on the DNA scale of size at depths greater than similar to 10 mu m and at distances greater than similar to 1 mu m from the beam centre. Here the ionisation cluster size for each beam is less than similar to 100. The radial dose deposition is also approximately equal at large depths and at distances greater than 10 mu m from the beam centre.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 19 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[3]  
[Anonymous], RAD RES
[4]   CONSTRAINTS ON ENERGY DEPOSITION AND TARGET SIZE OF MULTIPLY DAMAGED SITES ASSOCIATED WITH DNA DOUBLE-STRAND BREAKS [J].
BRENNER, DJ ;
WARD, JF .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1992, 61 (06) :737-748
[5]   A free-parameter theoretical model for describing the electron elastic scattering in water in the Geant4 toolkit [J].
Champion, C. ;
Incerti, S. ;
Aouchiche, H. ;
Oubaziz, D. .
RADIATION PHYSICS AND CHEMISTRY, 2009, 78 (09) :745-750
[6]   Microdosimetry in high-resolution cellular phantoms using the very low energy electromagnetic extension of the Geant4 toolkit [J].
Chauvie, S. ;
Incerti, S. ;
Moretto, P. ;
Pia, M. G. ;
Seznec, H. .
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, :2086-2088
[7]   Geant4 physics processes for microdosimetry simulation: Design foundation and implementation of the first set of models [J].
Chauvie, S. ;
Francis, Z. ;
Guatelli, S. ;
Incerti, S. ;
Mascialino, B. ;
Moretto, P. ;
Nieminen, P. ;
Pia, M. G. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (06) :2619-2628
[8]   Monte Carlo simulation of the production of short DNA fragments by low-linear energy transfer radiation using higher-order DNA models [J].
Friedland, W ;
Jacob, P ;
Paretzke, HG ;
Stork, T .
RADIATION RESEARCH, 1998, 150 (02) :170-182
[9]  
Hubbell J.H., 2019, XRAY MASS ATTENUATIO
[10]   Monte Carlo dosimetry for targeted irradiation of individual cells using a microbeam facility [J].
Incerti, S. ;
Seznec, H. ;
Simon, M. ;
Barberet, Ph. ;
Habchi, C. ;
Moretto, Ph. .
RADIATION PROTECTION DOSIMETRY, 2009, 133 (01) :2-11