Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients

被引:2
作者
Barros Oliveira Sa, Michel Pompeu [1 ,2 ,3 ,4 ]
Pereira Cavalcanti, Luiz Rafael [1 ,2 ]
Rayol, Sergio da Costa [1 ,2 ]
Silva Diniz, Roberto Gouvea [1 ,2 ]
Menezes, Alexandre Motta [1 ,2 ]
Clavel, Marie-Annick [1 ,5 ]
Pibarot, Philippe [1 ,5 ]
Lima, Ricardo Carvalho [1 ,2 ,3 ,4 ]
机构
[1] Pronto Socorro Cardiol Pernambuco PROCAPE, Dept Cardiovasc Surg, Recife, PE, Brazil
[2] Univ Pernambuco UPE, Recife, PE, Brazil
[3] Fac Ciencias Med, Nucleus Postgrad Studies & Res Hlth Sci, Recife, PE, Brazil
[4] Inst Ciencias Biol, Recife, PE, Brazil
[5] Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
关键词
Mitral Valve/Surgery; Heart Valve Prosthesis; Meta-Analysis; Prosthesis-Patient Mismatch; IMPACT; SURVIVAL; CHILDREN; INFANTS;
D O I
10.21470/1678-9741-2019-0069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study sought to evaluate the impact of prosthesis-patient mismatch on the risk of perioperative and long-term mortality after mitral valve replacement. Methods: Databases were researched for studies published until December 2018. Main outcomes of interest were perioperative and 10-year mortality and echocardiographic parameters. Results: The research yielded 2,985 studies for inclusion. Of these, 16 articles were analyzed, and their data extracted. The total number of patients included was 10,239, who underwent mitral valve replacement. The incidence of prosthesis-patient mismatch after mitral valve replacement was 53.7% (5,499 with prosthesis-patient mismatch and 4,740 without prosthesis-patient mismatch). Perioperative (OR 1.519; 95% CI 1.194-1.931, P<0.001) and 10-year OR 1.515; 95% CI 1.280-1.795, P<0.001) mortality was increased in patients with prosthesis-patient mismatch. Patients with prosthesis-patient mismatch after mitral valve replacement had higher systolic pulmonary artery pressure and transprosthethic gradient and lower indexed effective orifice area and left ventricle ejection fraction. Conclusion: Prosthesis-patient mismatch increases perioperative and long-term mortality. Prosthesis-patient mismatch is also associated with pulmonary hypertension and depressed left ventricle systolic function. The findings of this study support the implementation of surgical strategies to prevent prosthesis-patient mismatch in order to decrease mortality rates.
引用
收藏
页码:203 / 212
页数:10
相关论文
共 29 条
[1]   Clinical course and hemodynamic observations after supraannular mitral valve replacement in infants and children [J].
Adatia, I ;
Moore, PM ;
Jonas, RA ;
Colan, SD ;
Lock, JE ;
Keane, JF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (05) :1089-1094
[2]   Prosthesis-patient mismatch after mitral valve replacement: a single-centered retrospective analysis in East China [J].
Akuffu, Armah M. ;
Zhao, Haige ;
Zheng, Junnan ;
Ni, Yiming .
JOURNAL OF CARDIOTHORACIC SURGERY, 2018, 13
[3]   Effect of prosthesis patient mismatch in mitral position on pulmonary hypertension [J].
Ammannaya, Ganesh Kumar K. ;
Mishra, Prashant ;
Khandekar, Jayant V. ;
Mohapatra, Chandan Kumar Ray ;
Seth, Harsh S. ;
Raut, Chaitanya ;
Shah, Vaibhav ;
Saini, Jaskaran S. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (06) :1168-1174
[4]   Impact of prosthesis-patient mismatch on tricuspid valve regurgitation and pulmonary hypertension following mitral valve replacement [J].
Angeloni, Emiliano ;
Melina, Giovanni ;
Benedetto, Umberto ;
Roscitano, Antonino ;
Refice, Simone ;
Quarto, Cesare ;
Comito, Cosimo ;
Pibarot, Philippe ;
Sinatra, Riccardo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) :4150-4154
[5]   Factors Affecting Survival After Mitral Valve Replacement in Patients With Prosthesis-Patient Mismatch [J].
Aziz, Abdulhameed ;
Lawton, Jennifer S. ;
Maniar, Hersh S. ;
Pasque, Michael K. ;
Damiano, Ralph J., Jr. ;
Moon, Marc R. .
ANNALS OF THORACIC SURGERY, 2010, 90 (04) :1202-1210
[6]   Surgical aortic valve replacement and patient-prosthesis mismatch: a meta-analysis of 108 182 patients [J].
Barros de Oliveira Sa, Michel Pompeu ;
Barros de Carvalho, Martinha Millianny ;
Sobral Filho, Dario Celestino ;
Pereira Cavalcanti, Luiz Rafael ;
Rayol, Sergio da Costa ;
Silva Diniz, Roberto Gouvea ;
Menezes, Alexandre Motta ;
Clavel, Marie-Annick ;
Pibarot, Philippe ;
Lima, Ricardo Carvalho .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (01) :44-54
[7]   OPERATING CHARACTERISTICS OF A BANK CORRELATION TEST FOR PUBLICATION BIAS [J].
BEGG, CB ;
MAZUMDAR, M .
BIOMETRICS, 1994, 50 (04) :1088-1101
[8]   Incidence of prosthesis-patient mismatch in patients receiving mitral Biocor® porcine prosthetic valves [J].
Borracci, Raul A. ;
Rubio, Miguel ;
Sestito, Maria L. ;
Ingino, Carlos A. ;
Barrero, Carlos ;
Rapallo, Carlos A. .
CARDIOLOGY JOURNAL, 2016, 23 (02) :178-183
[9]   Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch After Mitral Valve Replacement: A Chinese Multicenter Clinical Study [J].
Cao, Hua ;
Qiu, Zhihuang ;
Chen, Liangwan ;
Chen, Daozhong ;
Chen, Qiang .
MEDICAL SCIENCE MONITOR, 2015, 21 :2542-2546
[10]   Prosthesis-Patient Mismatch after Mitral Valve Replacement: Comparison of Different Methods of Effective Orifice Area Calculation [J].
Cho, In-Jeong ;
Hong, Geu-Ru ;
Lee, Seung Hyun ;
Lee, Sak ;
Chang, Byung-Chul ;
Shim, Chi Young ;
Chang, Hyuk-Jae ;
Ha, Jong-Won ;
Chung, Namsik .
YONSEI MEDICAL JOURNAL, 2016, 57 (02) :328-336