Experimental and numerical study on corona onset threshold under combined AC-DC voltages in Wire-Plane electrodes

被引:5
作者
Ma, Ziyu [1 ]
Xia, Junyi [1 ]
He, Xuyuan [2 ]
Zhou, Yunbo [1 ]
He, Zichen [1 ]
Li, Qi [3 ]
Bian, Xingming [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewable, Beijing 102206, Peoples R China
[2] State Grid Langfang Power Supply Co, Langfang 065000, Hebei, Peoples R China
[3] Chongqing Univ, 174 Shazheng Rd, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
Corona discharge; Corona onset voltage; Combined AC-DC voltages; Wire-plane electrode; Space charge; ION-FLOW-FIELD; INTENSITY CHARACTERISTICS; AIR-PRESSURE; HYBRID; HUMIDITY; PERFORMANCE; DISCHARGE; PULSES; ROD;
D O I
10.1016/j.ijepes.2022.108479
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the large-scale application of hybrid HVDC/HVAC transmission technology, the phenomenon of corona discharge is also intensified. This paper attempts to provide a comprehensive understanding of the variation of corona onset voltage under combined AC-DC voltages. In this paper, an experimental platform for measuring corona onset voltage and current pulses of wire-plane electrode under combined AC-DC voltages was built. A new corona model of wire-plane electrode under combined AC-DC voltages was also established by using the fluid model and the ion flow field model. The corona onset voltages of wire-plane electrode under different ratios of AC and DC voltages, conductor radius and conductor spacing were measured. It turned out that the conductor radius affected the intercept of the corona onset curve, while the conductor spacing affected the slope. In addition, the type of corona only affected the intercept of the corona onset curve, not the slope. With the same fixed voltage of non-corona conductor, the corona onset voltage of the DC-side positive corona was the largest, followed by the DC-side negative corona, then was the AC-side positive half-cycle corona, and the smallest was the AC-side negative half-cycle corona. The interaction between AC voltage and DC voltage was approximately linear. The calculations of the model illustrated that the residual space charges had a blocking effect on corona discharge. Therefore, the more residual space charge was, the higher corona onset voltage would be.
引用
收藏
页数:12
相关论文
共 38 条
  • [1] Universal branch model for the solution of optimal power flows in hybrid AC/DC grids
    Alvarez-Bustos, Abraham
    Kazemtabrizi, Behzad
    Shahbazi, Mahmoud
    Acha-Daza, Enrique
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 126
  • [2] The role of low air pressure in the variation of negative corona-generated space charge in a rod to plane electrode
    Bian XingMing
    Zhu JunYu
    Yang Wei
    Wan ShuWei
    Qi Lei
    Li XueBao
    Li HaiBing
    [J]. HIGH VOLTAGE, 2018, 3 (02): : 126 - 132
  • [3] Development of DIP-based algorithm for extraction of UV video attributes from corona discharges on polymeric insulators
    Brito, K. B.
    Costa, E. G.
    Dias, B. A.
    Florentino, M. T. B.
    Lira, G. R. S.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 134
  • [4] INVESTIGATION OF CORONA AND FIELD EFFECTS OF AC-DC HYBRID TRANSMISSION-LINES
    CHARTIER, VL
    SARKINEN, SH
    STEARNS, RD
    BURNS, AL
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (01): : 72 - 80
  • [5] THE EFFECT OF HVAC HVDC LINE SEPARATION IN A HYBRID CORRIDOR
    CLAIRMONT, BA
    JOHNSON, GB
    ZAFFANELLA, LE
    ZELINGHER, S
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (02) : 1338 - 1350
  • [6] Numerical simulation of the Trichel pulse characteristics in SF6/N2 gas mixtures
    Gao, Qingqing
    Wang, Xiaohua
    Adamiak, Kazimierz
    Yang, Aijun
    Liu, Dingxin
    Rong, Mingzhe
    Zhang, Jiawei
    [J]. PHYSICS OF PLASMAS, 2020, 27 (11)
  • [7] Influence of freezing water conductivity on the positive corona performance of soft rime ice-covered conductor
    He, Gaohui
    Hu, Qin
    Wu, Bin
    Shu, Lichun
    Jiang, Xingliang
    Xiao, Longfang
    Yu, Zhou
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 112 : 137 - 143
  • [8] He X., 2021, IEEE ACCESS, V9
  • [9] Experiments and Analysis of Corona Inception Voltage Under Combined AC-DC Voltages at Various Air Pressure and Humidity in Rod to Plane Electrodes
    He, Zichen
    Zhu, Junyu
    Zhu, Jie
    Bian, Xingming
    Shen, Boyang
    [J]. CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2021, 7 (04) : 875 - 888
  • [10] Outdoor Investigation of the Corona Characteristics and Audible Noise of a Hybrid AC/DC Overhead Line
    Hedtke, S.
    Bleuler, P.
    Franck, C. M.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (06) : 3309 - 3317