Concurrent Validity of Resting Pulse-Rate Measurements: A Comparison of 2 Smartphone Applications, the Polar H7 Belt Monitor, and a Pulse Oximeter With Bluetooth

被引:34
作者
Cheatham, Scott W. [1 ]
Kolber, Morey J. [2 ]
Ernst, Michael P. [1 ]
机构
[1] Calif State Univ Dominguez Hills, Div Kinesiol & Recreat, Carson, CA 90747 USA
[2] Nova SE Univ, Dept Phys Therapy, Ft Lauderdale, FL 33314 USA
关键词
mobile technology; heart; smartphone apps; HEART-RATE-VARIABILITY; ACCURACY; SYSTEM; RELIABILITY; VALIDATION; AGREEMENT; INTERVAL; S810; ECG;
D O I
10.1123/jsr.2013-0145
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Pulse rate is commonly measured manually or with commercial wrist or belt monitors. More recently, pulse-rate monitoring has become convenient with the use of mobile technology that allows monitoring through a smartphone camera. This optical technology offers many benefits, although the clinimetric properties have not been extensively studied. Design: Observational study of reliability Setting: University kinesiology laboratory. Participants: 30 healthy, recreationally active adults. Intervention: Concurrent measurement of pulse rate using 2 smartphone applications (fingertip, face-scan,) with the Polar H7 belt and pulse oximeter. Main Outcome Measure: Average resting pulse rate for 5 min in 3 positions (supine, sitting, and prone). Results: Concurrent validity in supine and standing was good between the 2 applications and the Polar H7 (intraclass correlation coefficient [ICC].80-.98) and pulse oximeter (ICC.82-.98). For sitting, the validity was good between the fingertip application, Polar H7 (ICC.97), and pulse oximeter (ICC.97). The face-scan application had moderate validity with the Polar H7 (ICC.74) and pulse oximeter (ICC.69). The minimal detectable change (MDC90) between the fingertip application and Polar H7 ranged from 1.38 to 4.36 beats/min (BPM) and from 0.69 to 2.97 BPM for the pulse oximeter with both positions. The MDC90 between the face-scan application and Polar H7 ranged from 11.88 to 12.83 BPM and from 0.59 to 17.72 BPM for the pulse oximeter. The 95% limits of agreement suggest that the fingertip application may vary between 2.40 and 3.59 BPM with the Polar H7 and between 3.40 and 3.42 BPM with the pulse oximeter. The face-scan application may vary between 3.46 and 3.52 BPM with the Polar H7 and between 2.54 and 3.46 BPM with the pulse oximeter. Conclusion: Pulse-rate measurements may be effective using a fingertip application, belt monitor, and pulse oximeter. The fingertip scanner showed superior results compared with the face scanner, which only demonstrated modest validity compared with the Polar H7 and pulse oximeter.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 29 条
[1]  
Bolkhovsky JB., 2012, Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
[2]  
Contec I, PULS OX
[3]   On the Analysis of Fingertip Photoplethysmogram Signals [J].
Elgendi, Mohamed .
CURRENT CARDIOLOGY REVIEWS, 2012, 8 (01) :14-25
[4]   Interrater agreement and interrater reliability: Key concepts, approaches, and applications [J].
Gisev, Natasa ;
Bell, J. Simon ;
Chen, Timothy F. .
RESEARCH IN SOCIAL & ADMINISTRATIVE PHARMACY, 2013, 9 (03) :330-338
[5]   Interpreting change scores of tests and measures used in physical therapy [J].
Haley, SM ;
Fragala-Pinkham, MA .
PHYSICAL THERAPY, 2006, 86 (05) :735-743
[6]  
HARRIS AP, 1993, AM J PERINAT, V10, P250
[7]   Smartphone-enabled pulse rate variability: An alternative methodology for the collection of heart rate variability in psychophysiological research [J].
Heathers, James A. J. .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2013, 89 (03) :297-304
[8]   Artificial acrylic finger nails may alter pulse oximetry measurement [J].
Hinkelbein, Jochen ;
Koehler, Heike ;
Genzwuerker, Harald V. ;
Fiedler, Fritz .
RESUSCITATION, 2007, 74 (01) :75-82
[9]   Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients [J].
Hinkelbein, Jochen ;
Genzwuerker, Harald V. ;
Sogl, Reiner ;
Fiedler, Fritz .
RESUSCITATION, 2007, 72 (01) :82-91
[10]  
HOLLERBACH AD, 1990, HEART LUNG, V19, P258