Pressure-Triggered Microfluidic Contact Lens for Ocular Drug Delivery

被引:20
作者
Du, Zhichang [1 ,2 ]
Zhao, Gangnan [2 ]
Wang, Anyang [2 ]
Sun, Wei [3 ]
Mi, Shengli [2 ]
机构
[1] Jimei Univ, Coll Mech & Energy Engn, Xiamen 361021, Peoples R China
[2] Tsinghua Univ, Tsinghua Shenzhen Int, Biomfg Engn Lab, Grad Sch, Shenzhen 518055, Peoples R China
[3] Tsinghua Berkeley Shenzhen Inst, Precis Med & Healthcare Res Ctr, Shenzhen 518055, Peoples R China
关键词
wearable devices; microfluidic; contact lens; drug delivery; micropump; IN-VIVO EVALUATION; SENSOR; VITRO; PDMS;
D O I
10.1021/acsapm.2c01118
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Microfluidic technology has been used for precise drug delivery for many years, but microfluidic wearable devices have mostly been used for skin drug delivery. The application of eye drops is currently one of the most common ways to treat eye diseases. However, due to their low corneal bioavailability and short residence time in tears, topical eye drops must be applied multiple times a day. Contact lenses, as a wearable device for the eye, are a good platform for drug delivery. In this paper, we propose a type of microfluidic contact lens that integrates a microchannel and a micropump and uses a pressure source to trigger the release of a drug. Here, a flat microfluidic chip component is first fabricated by photolithography and then cast into a curved surface by secondary thermosetting. Through experiments, the outlet check valve opening pressure and liquid flow test were studied to prove that the liquid release is controllable. In addition, the microfluidic contact lens has good flexibility, light transmittance, and biocompatibility. Finally, we demonstrate through fluorescence experiments that the microfluidic contact lens can be loaded with different types of drugs in different regions. In general, liquid exchange between the eye and the contact lens can be realized through the mechanical action of blinking without using electronic components, meaning more safety and stability. The mechanical characteristics of a blink can be artificially regulated to a large extent; thus, it is also possible to achieve specific, personalized medicine.
引用
收藏
页码:7290 / 7299
页数:10
相关论文
共 51 条
[1]   Ultra-sensitive microfluidic wearable strain sensor for intraocular pressure monitoring [J].
Agaoglu, Sevda ;
Diep, Priscilla ;
Martini, Matthew ;
Samudhyatha, K. T. ;
Baday, Murat ;
Araci, I. Emre .
LAB ON A CHIP, 2018, 18 (22) :3471-3483
[2]   Polysaccharide-Based Bilayer Coatings for Biofilm-Inhibiting Surfaces of Medical Devices [J].
Ajdnik, Urban ;
Luxbacher, Thomas ;
Vesel, Alenka ;
Stern, Alja ;
Zegura, Bojana ;
Trcek, Janja ;
Zemljic, Lidija Fras .
MATERIALS, 2021, 14 (16)
[3]   Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices [J].
Akther, Fahima ;
Yakob, Shazwani Binte ;
Nam-Trung Nguyen ;
Ta, Hang T. .
BIOSENSORS-BASEL, 2020, 10 (11)
[4]   A method of manufacturing microfluidic contact lenses by using irreversible bonding and thermoforming [J].
An, Hongbin ;
Chen, Liangzhou ;
Liu, Xiaojun ;
Zhao, Bin ;
Ma, Donglin ;
Wu, Zhigang .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2018, 28 (10)
[5]  
[Anonymous], 2017, Int J Drug Dev Res
[6]   An implantable microfluidic device for self-monitoring of intraocular pressure [J].
Araci, Ismail E. ;
Su, Baolong ;
Quake, Stephen R. ;
Mandel, Yossi .
NATURE MEDICINE, 2014, 20 (09) :1074-1078
[7]   Contact Lenses for Color Blindness [J].
Badawy, Abdel-Rahman ;
Hassan, Muhammad Umair ;
Elsherif, Mohamed ;
Ahmed, Zubair ;
Yetisen, Ali K. ;
Butt, Haider .
ADVANCED HEALTHCARE MATERIALS, 2018, 7 (12)
[8]   Development of an In Vitro Blink Model for Ophthalmic Drug Delivery [J].
Chau-Minh Phan ;
Shukla, Manish ;
Walther, Hendrik ;
Heynen, Miriam ;
Suh, David ;
Jones, Lyndon .
PHARMACEUTICS, 2021, 13 (03) :1-10
[9]   Soft wearable contact lens sensor for continuous intraocular pressure monitoring [J].
Chen, Guo-Zhen ;
Chan, Ion-Seng ;
Leung, Leo K. K. ;
Lam, David C. C. .
MEDICAL ENGINEERING & PHYSICS, 2014, 36 (09) :1134-1139
[10]   Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring [J].
Chen, Guo-Zhen ;
Chan, Ion-Seng ;
Lam, David C. C. .
SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 :112-118