Volumetric-modulated arc therapy planning using multicriteria optimization for localized prostate cancer

被引:34
作者
Ghandour, Sarah [1 ]
Matzinger, Oscar [1 ]
Pachoud, Marc [1 ]
机构
[1] Riviera Chablais Hosp, Dept Radiotherapy, Ctr Canc, CH-1800 Vevey, Switzerland
关键词
VMAT; MCO; prostate; treatment planning; deliverability; CONVEX PARETO SURFACES; DOSE DISTRIBUTIONS; IMRT; RADIOTHERAPY; QUALITY; VMAT; CONSTRAINTS; SYSTEM; MINIMA;
D O I
10.1120/jacmp.v16i3.5410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to evaluate the volumetric-modulated arc therapy (VMAT) multicriteria optimization (MCO) algorithm clinically available in the RayStation treatment planning system (TPS) and its ability to reduce treatment planning time while providing high dosimetric plan quality. Nine patients with localized prostate cancer who were previously treated with 78 Gy in 39 fractions using VMAT plans and ray Arc system based on the direct machine parameter optimization (DMPO) algorithm were selected and replanned using the VMAT-MCO system. First, the dosimetric quality of the plans was evaluated using multiple conformity metrics that account for target coverage and sparing of healthy tissue, used in our departmental clinical protocols. The conformity and homogeneity index, number of monitor units, and treatment planning time for both modalities were assessed. Next, the effects of the technical plan parameters, such as constraint leaf motion CLM (cm/degrees) and maximum arc delivery time T (s), on the accuracy of delivered dose were evaluated using quality assurance passing rates (QAs) measured using the Delta(4) phantom from ScandiDos. For the dosimetric plan's quality analysis, the results show that the VMAT-MCO system provides plans comparable to the ray Arc system with no statistical difference for V95% (p < 0.01), Dl% (p < 0.01), CI (p < 0.01), and HI (p < 0.01) of the PTV, bladder (p < 0.01), and rectum (p < 0.01) constraints, except for the femoral heads and healthy tissues, for which a dose reduction was observed using MCO compared with ray Arc (p < 0.01). The technical parameter study showed that a combination of CLM equal to 0.5 cm/degree and a maximum delivery time of 72 s allowed the accurate delivery of the VMAT-MCO plan on the Elekta Versa HD linear accelerator. Planning evaluation and dosimetric measurements showed that VMAT-MCO can be used clinically with the advantage of enhanced planning process efficiency by reducing the treatment planning time without impairing dosimetric quality.
引用
收藏
页码:258 / 269
页数:12
相关论文
共 36 条
[1]  
[Anonymous], INT J RAD ONCOL BIOL
[2]   High conformality radiotherapy in Europe: thirty-one centres participating in the quality assurance programme of the EORTC prostate trial 22991 [J].
Ataman, F ;
Poortmans, P ;
Davis, JB ;
Bernier, J ;
Giraud, JY ;
Kouloulias, VE ;
Pierart, M ;
Bolla, M .
EUROPEAN JOURNAL OF CANCER, 2004, 40 (16) :2411-2416
[3]   How important is dosimetrist experience for intensity modulated radiation therapy? A comparative analysis of a head and neck case [J].
Batumalai, Vikneswary ;
Jameson, Michael G. ;
Forstner, Dion F. ;
Vial, Philip ;
Holloway, Lois C. .
PRACTICAL RADIATION ONCOLOGY, 2013, 3 (03) :E99-E106
[4]   Beam modeling and VMAT performance with the Agility 160-leaf multileaf collimator [J].
Bedford, James L. ;
Thomas, Michael D. R. ;
Smyth, Gregory .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02) :172-185
[5]   IMRT treatment planning -: A comparative inter-system and intor-centre planning exercise of the ESTRO QUASIMODO group [J].
Bohsung, J ;
Gillis, S ;
Arrans, R ;
Bakai, A ;
De Wagter, C ;
Knöös, T ;
Mijnheer, BJ ;
Paiusco, M ;
Perrin, BA ;
Welleweerd, H ;
Williams, P .
RADIOTHERAPY AND ONCOLOGY, 2005, 76 (03) :354-361
[6]  
Bokrantz R, 2013, THESIS KTH STOCKHOLM
[7]   An Algorithm for Approximating Convex Pareto Surfaces Based on Dual Techniques [J].
Bokrantz, Rasmus ;
Forsgren, Anders .
INFORMS JOURNAL ON COMPUTING, 2013, 25 (02) :377-393
[8]   Multicriteria optimization for volumetric-modulated arc therapy by decomposition into a fluence-based relaxation and a segment weight-based restriction [J].
Bokrantz, Rasmus .
MEDICAL PHYSICS, 2012, 39 (11) :6712-6725
[9]   Development and evaluation of an efficient approach to volumetric arc therapy planning [J].
Bzdusek, Karl ;
Friberger, Henrik ;
Eriksson, Kjell ;
Hardemark, Bjorn ;
Robinson, David ;
Kaus, Michael .
MEDICAL PHYSICS, 2009, 36 (06) :2328-2339
[10]   Multicriteria optimization informed VMAT planning [J].
Chen, Huixiao ;
Craft, David L. ;
Gierga, David P. .
MEDICAL DOSIMETRY, 2014, 39 (01) :64-73