Pulsed flow modulation comprehensive two-dimensional gas chromatography

被引:49
作者
Poliak, Marina [1 ]
Kochman, Maya [1 ]
Amirav, Aviv [1 ]
机构
[1] Tel Aviv Univ, Sackler Fac Exact Sci, Sch Chem, IL-69978 Tel Aviv, Israel
基金
以色列科学基金会;
关键词
comprehensive two-dimensional gas chromatography; flow modulation; pulsed flow modulation;
D O I
10.1016/j.chroma.2007.09.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Pulsed flow modulation (PFM) is based on higher flow rate time compression of the first GC column effluent, which prior to the injection into the second column is stored for a few seconds in a standard fused silica wide bore transfer line. We constructed the PFM device with two standard 1/16 in. brass compression fittings with the insertion of the two columns inside the wide bore 0.53 mm W. fused silica storage transfer line for the elimination of dead volumes. This simple arrangement provides a combination of flexibility in the length of the sample storage transfer line hence comprehensive two-dimensional gas chromatography (GC x GC) cycle time, inert sample path and full elimination of cooling gas consumption. A record short second column injection time of 20 ms is demonstrated. Practical injection times are the sample collection time (such as 4 s) divided by the second to first column flow rate ratio (such as 20/0.7), which is typically around 150 ms. Due to the low cost of the device it can also be considered for use with non comprehensive time segmented GC x GC to remove a few accidental coelutions. PFM-GC x GC excels with high second column capacity due to the use of 0.32 mm i.d. columns with high flow rates as the second dimension GC x GC column. As a result, PFM-GC x GC can have up to two orders of magnitude higher second column sample capacity and linear dynamic range for improved reduction of adverse matrix interference effects due to column overloading. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 195
页数:7
相关论文
共 28 条
  • [1] Supersonic gas chromatography/mass spectrometry
    Amirav, A
    Gordin, A
    Tzanani, N
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (10) : 811 - 820
  • [2] Bertsch W, 1999, HRC-J HIGH RES CHROM, V22, P647, DOI 10.1002/(SICI)1521-4168(19991201)22:12<647::AID-JHRC647>3.0.CO
  • [3] 2-V
  • [4] FAST, HIGH-TEMPERATURE AND THERMOLABILE GC MS IN SUPERSONIC MOLECULAR-BEAMS
    DAGAN, S
    AMIRAV, A
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 133 (2-3): : 187 - 210
  • [5] Comprehensive two-dimensional gas chromatography:: a powerful and versatile analytical tool
    Dallüge, J
    Beens, J
    Brinkman, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) : 69 - 108
  • [6] A new type of GC-MS with advanced capabilities
    Fialkov, AB
    Steiner, U
    Jones, L
    Amirav, A
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 251 (01) : 47 - 58
  • [7] Overloading of the second-dimension column in comprehensive two-dimensional gas chromatography
    Harynuk, J
    Górecki, T
    de Zeeuw, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) : 21 - 27
  • [8] Flow modulation comprehensive two-dimensional gas chromatography-mass spectrometry with a supersonic molecular beam
    Kochman, Maya
    Gordin, Alexander
    Alon, Tal
    Amirav, Aviv
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1129 (01) : 95 - 104
  • [9] A systematic analysis of a flow-switching modulator for comprehensive two-dimensional gas chromatography
    LaClair, RW
    Bueno, PA
    Seeley, JV
    [J]. JOURNAL OF SEPARATION SCIENCE, 2004, 27 (5-6) : 389 - 396
  • [10] COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY USING AN ON-COLUMN THERMAL MODULATOR INTERFACE
    LIU, ZY
    PHILLIPS, JB