Polymeric coating of surface modified nitinol stent with POSS-nanocomposite polymer

被引:40
|
作者
Bakhshi, Raheleh [1 ,2 ]
Darbyshire, Arnold [1 ]
Evans, James Eaton [3 ]
You, Zhong [3 ]
Lu, Jian [4 ]
Seifalian, Alexander M. [1 ,5 ]
机构
[1] UCL, Ctr Nanotechnol & Regenerat Med, London, England
[2] UCL, Dept Mech Engn, London, England
[3] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[4] Univ Manchester, Sch Phys & Astron, Manchester, Lancs, England
[5] UCL, Royal Free Hampstead NHS Trust Hosp, Ctr Nanotechnol & Regenerat Med, London, England
基金
英国工程与自然科学研究理事会;
关键词
NiTi; Nanocomposite; Surface modification; Aminosilane; Electrohydrodynamic spraying; Stent; DRUG-ELUTING STENTS; SHAPE-MEMORY ALLOYS; IN-VITRO; TITANIUM; BIOCOMPATIBILITY; CORROSION; ENDOTHELIALIZATION; POLYURETHANES; BIOMATERIAL; RESISTANCE;
D O I
10.1016/j.colsurfb.2011.03.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Stent angioplasty is a successful treatment for arterial occlusion, particularly in coronary artery disease. The clinical communities were enthusiastic about the use of drug-eluting stents; however, these stents have a tendency to be a contributory factor towards late stage thrombosis, leading to mortality in a significant number of patients per year. This work presents an innovative approach in self-expanding coronary stents preparation. We developed a new nanocomposite polymer based on polyhedral oligomeric silsesquioxanes (POSS) and poly(carbonate-urea)urethane (PCU), which is an antithrombogenic and a non-biodegradable polymer with in situ endothelialization properties. The aim of this work is to coat a NiTi stent alloy with POSS-PCU. In prolonged applications in the human body, the corrosion of the NiTi alloy can result in the release of deleterious ions which leads to unwanted biological reactions. Coating the nitinol (NiTi) surface with POSS-PCU can enhance surface resistance and improve biocompatibility. Electro-hydrodynamic spraying was used as the polymer deposition process and thus a few experiments were carried out to compare this process with casting. Prior to deposition the NiTi has been surface modified. The peel strength of the deposit was studied before and after degradation of the coating. It is shown that the surface modification enhances the peel strength by 300%. It is also indicated how the adhesion strength of the POSS-PCU coating changes post-exposure to physiological solutions comprised of hydrolytic, oxidative, peroxidative and biological media. This part of the study shows that the modified NiTi presents far greater resistance to decay in peel strength compared to the non-modified NiTi. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 105
页数:13
相关论文
共 50 条
  • [21] Coating stability and blood compatibility of stainless steel surface modified with phospholipid polymer
    Morimoto, N
    Sato, I
    Watanabe, A
    Nakabayashi, N
    Iwasaki, Y
    Ishihara, K
    KOBUNSHI RONBUNSHU, 2002, 59 (07) : 432 - 437
  • [22] An Anti-CD34 Antibody-Functionalized Clinical-Grade POSS-PCU Nanocomposite Polymer for Cardiovascular Stent Coating Applications: A Preliminary Assessment of Endothelial Progenitor Cell Capture and Hemocompatibility
    Tan, Aaron
    Goh, Debbie
    Farhatnia, Yasmin
    Natasha, G.
    Lim, Jing
    Teoh, Swee-Hin
    Rajadas, Jayakumar
    Alavijeh, Mohammad S.
    Seifalian, Alexander M.
    PLOS ONE, 2013, 8 (10):
  • [23] A physico-mechanical investigation of a novel hyperbranched polymer-modified clay/epoxy nanocomposite coating
    Sari, Morteza Ganjaee
    Ramezanzadeh, Bahram
    Pakdel, Amir Saeid
    Shahbazi, Mohammad
    PROGRESS IN ORGANIC COATINGS, 2016, 99 : 263 - 273
  • [24] Evaluation of a novel paclitaxel-eluting stent with a bioabsorbable polymeric surface coating in the porcine artery injury model
    Ding, Fuyan
    Lu, Zhiqian
    Zou, Rongjiang
    Zhang, Yi
    Guo, Qingkui
    Li, Suming
    Yang, Jian
    ACTA CARDIOLOGICA, 2011, 66 (06) : 765 - 772
  • [25] Spatial structures formation of surface-modified nanoparticles in polymer nanocomposite thin films
    Kobayashi, Naoto
    Yagawa, Shogo
    Nakamura, Yusaku
    Kubo, Masaki
    Shoji, Eita
    Tsukada, Takao
    Adschiri, Tadafumi
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 155
  • [26] Polymer Nanocomposite-Modified Asphalt: Characterisation and Optimisation Using Response Surface Methodology
    Bala, Nura
    Kamaruddin, Ibrahim
    Napiah, Madzlan
    Sutanto, Muslich Hartadi
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (05) : 4233 - 4243
  • [27] Polymer Nanocomposite-Modified Asphalt: Characterisation and Optimisation Using Response Surface Methodology
    Nura Bala
    Ibrahim Kamaruddin
    Madzlan Napiah
    Muslich Hartadi Sutanto
    Arabian Journal for Science and Engineering, 2019, 44 : 4233 - 4243
  • [28] Adhesion of endothelial cells on the surface of intravascular stent modified by plasma coating under fluid shear stress
    Wang, G. -X.
    Tang, C. -J.
    Cao, Y.
    Xiao, L.
    Qiu, J. -H.
    Shen, Y.
    Yu, Q. -S.
    BIORHEOLOGY, 2008, 45 (1-2) : 129 - 129
  • [29] Highly effective antibiofilm coating of silver-polymer nanocomposite on polymeric medical devices deposited by one step plasma process
    Agarwala, Munin
    Barman, Tapan
    Gogoi, Dolly
    Choudhury, Bula
    Pal, Arup R.
    Yadav, R. N. S.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2014, 102 (06) : 1223 - 1235
  • [30] Preparation of Fluoroalkyl-Acrylate-Modified Polysiloxane Nanocomposite and Its Surface Properties as a Superhydrophobic Coating Material
    Deng, Fuquan
    Jin, Hua
    Xu, Wei
    COATINGS, 2019, 9 (10)