Readout ASIC for 3D position-sensitive detectors

被引:7
作者
De Geronimo, Gianluigi [1 ]
Vernon, Emerson [1 ]
Ackley, Kim [1 ]
Dragone, Angelo [2 ]
Fried, Jack [1 ]
O'Connor, Paul [1 ]
He, Zhong
Herman, Cedric [3 ]
Zhang, Feng [3 ]
机构
[1] Brookhaven Natl Lab, Instrumentat Div, Upton, NY 11973 USA
[2] Brookhaven Natl Lab, Natl Synchrotron Light Source Dept, Upton, NY USA
[3] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI USA
来源
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11 | 2007年
关键词
D O I
10.1109/NSSMIC.2007.4436284
中图分类号
O59 [应用物理学];
学科分类号
摘要
We describe an application specific integrated circuit (ASIC) for 3D position-sensitive detectors. It was optimized for pixelated CZT sensors, and it measures, corresponding to an ionizing event, the energy and timing of signals from 121 anodes and one cathode. Each channel provides low-noise charge amplification, high-order shaping, along with peak- and timing-detection. The cathode's timing can be measured in three different ways: the first is based on multiple thresholds on the charge amplifier's voltage output; the second uses the threshold crossing of a fast-shaped signal; and the third measures the peak amplitude and timing from a bipolar shaper. With its power of 2 mW per channel the ASIC measures, on a CZT sensor connected and biased, charges up to 100 W with an electronic resolution better than 200 e(-) rms. Our preliminary spectral measurements applying a simple cathode/anode ratio correction demonstrated a single-pixel resolution of 4.8 keV (0.72 %) at 662 keV, with the electronics and leakage current contributing in total with 2.1 keV.
引用
收藏
页码:32 / 41
页数:10
相关论文
共 50 条
[31]   Readout electronics for position-sensitive gas filled detectors at the European Synchrotron Radiation Facility [J].
Hervé, C ;
Le Caër, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :226-231
[32]   A QTC-based signal readout for position-sensitive multi-output detectors [J].
Zhou, Wei ;
Zhang, Zhi-Ming ;
Li, Dao-Wu ;
Wang, Pei-Lin ;
Feng, Bao-Tong ;
Huang, Xian-Chao ;
Hu, Ting-Ting ;
Li, Xiao-Hui ;
Chen, Yan ;
Wang, Ying-Jie ;
Liu, Yan-Tao ;
Zhang, Yi-Wen ;
Sun, Shi-Feng ;
Gu, Xiao-Yue ;
Yang, Ming-Jie ;
Xiao, Xiong ;
Wei, Long .
NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (05)
[33]   A QTC-based signal readout for position-sensitive multi-output detectors [J].
Wei Zhou ;
Zhi-Ming Zhang ;
Dao-Wu Li ;
Pei-Lin Wang ;
Bao-Tong Feng ;
Xian-Chao Huang ;
Ting-Ting Hu ;
Xiao-Hui Li ;
Yan Chen ;
Ying-Jie Wang ;
Yan-Tao Liu ;
Yi-Wen Zhang ;
Shi-Feng Sun ;
Xiao-Yue Gu ;
Ming-Jie Yang ;
Xiong Xiao ;
Long Wei .
Nuclear Science and Techniques, 2016, 27
[34]   Gap measurement by position-sensitive detectors [J].
Kim, JK ;
Kim, MS ;
Bae, JH ;
Kwon, JH ;
Lee, HB ;
Jeong, SH .
APPLIED OPTICS, 2000, 39 (16) :2584-2591
[35]   SEMICONDUCTOR POSITION-SENSITIVE DETECTORS. [J].
Radeka, V. .
Nuclear instruments and methods in physics research, 1983, 226 (01) :209-218
[36]   Gap measurement by position-sensitive detectors [J].
Kim, Jung-Ki ;
Kim, Man-Suhk ;
Bae, Jong Han ;
Kwon, Jin Hyuk ;
Lee, Hang-Boo ;
Jeong, Soo-Hoa .
Applied Optics, 2000, 39 (16) :2584-2591
[37]   MULTIPURPOSE ARRAY OF POSITION-SENSITIVE DETECTORS [J].
OBST, AW ;
BRAITHWA.WJ ;
DOSS, CR .
BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04) :528-528
[38]   POSITION-SENSITIVE SEMICONDUCTOR-DETECTORS [J].
LAEGSGAARD, E .
NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3) :93-111
[39]   FAST TIMING POSITION-SENSITIVE DETECTORS [J].
KLEIN, C ;
TROTSCHER, J ;
WOLLNIK, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2) :146-147
[40]   Noise analysis for position-sensitive detectors [J].
Narayanan, C ;
Buckman, AB ;
Busch-Vishniac, I .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (05) :1137-1144