Rat cardiovascular telemetry: Marginal distribution applied to positive control drugs

被引:9
作者
Accardi, M. V. [1 ]
Troncy, E. [2 ]
Abtout, S. [1 ]
Ascah, A. [1 ]
Maghezzi, S. [1 ]
Authier, S. [1 ,2 ]
机构
[1] CiToxLAB North Amer, 445 Armand Frappier, Laval, PQ H7V 4B3, Canada
[2] Univ Montreal, Fac Vet Med, POB 5000, St Hyacinthe, PQ J2S 7C6, Canada
关键词
Telemetry; Rat; Contractility; Left ventricular; Cloud analysis; ECG; PR; QT; LEFT-VENTRICULAR PRESSURE; CARDIAC CONTRACTILITY; BLOOD-PRESSURE; MYOCARDIAL-CONTRACTILITY; SAFETY PHARMACOLOGY; K+ CHANNEL; IN-VIVO; HEART; RADIOTELEMETRY; VALIDATION;
D O I
10.1016/j.vascn.2016.03.005
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Cardiovascular effects are considered frequent during drug safety testing. This investigation aimed to characterize the pharmacological response of the conscious telemetered rat in vivo model to known cardiovascular active agents. These effects were analyzed using statistical analysis and cloud representation with marginal distribution curves for the contractility index and heart rate as to assess the effect relationship between cardiac variables. Arterial blood pressure, left ventricular pressure, electrocardiogram and body temperature were monitored. The application of data cloud with marginal distribution curves to heart rate and contractility index provided an interesting tactic during the interpretation of drug-induced changes particularly during selective time resolution (i.e. marginal distribution curves restricted to T-max). Taken together, the present data suggests that marginal distribution curves can be a valuable interpretation strategy when using the rat cardiovascular telemetry model to detect drug-induced cardiovascular effects. Marginal distribution curves could also be considered during the interpretation of other inter-dependent parameters in safety pharmacology studies. (C) 2016 The Authors. Published by Elsevier Inc.
引用
收藏
页码:120 / 127
页数:8
相关论文
共 67 条
[21]  
Gad S. C., 2012, SAFETY PHARMACOLOGY
[22]  
Gauvin David V., 2006, Journal of Pharmacological and Toxicological Methods, V53, P128, DOI 10.1016/j.vascn.2005.11.004
[23]   Validation of a telemetry system for measurement of blood pressure, electrocardiogram and locomotor activity in beagle dogs [J].
Gelzer, ARM ;
Ball, HA .
CLINICAL AND EXPERIMENTAL HYPERTENSION, 1997, 19 (07) :1135-1160
[24]  
GLASS PSA, 1993, ANESTH ANALG, V77, P1031
[25]   Graphical Models for Ordinal Data [J].
Guo, Jian ;
Levina, Elizaveta ;
Michailidis, George ;
Zhu, Ji .
JOURNAL OF COMPUTATIONAL AND GRAPHICAL STATISTICS, 2015, 24 (01) :183-204
[26]   Preclinical cardiovascular risk assessment in modern drug development [J].
Guth, Brian D. .
TOXICOLOGICAL SCIENCES, 2007, 97 (01) :4-20
[27]   The evaluation of drug-induced changes in cardiac inotropy in dogs: Results from a HESI-sponsored consortium [J].
Guth, Brian D. ;
Chiang, Alan Y. ;
Doyle, Jennifer ;
Engwall, Michael J. ;
Guillon, Jean-Michel ;
Hoffmann, Peter ;
Koerner, John ;
Mittelstadt, Scott ;
Ottinger, Sean ;
Pierson, Jennifer Beck ;
Pugsley, Michael K. ;
Rossman, Eric I. ;
Walisser, Jacqueline ;
Sarazan, Dustan .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2015, 75 :70-90
[28]   Translation of flecainide- and mexiletine-induced cardiac sodium channel inhibition and ventricular conduction slowing from nonclinical models to clinical [J].
Heath, B. M. ;
Cui, Y. ;
Worton, S. ;
Lawton, B. ;
Ward, G. ;
Ballini, E. ;
Doe, C. P. A. ;
Ellis, C. ;
Patel, B. A. ;
McMahon, N. C. .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2011, 63 (03) :258-268
[29]  
Jacob HJ, 2010, METHODS MOL BIOL, V597, P1, DOI 10.1007/978-1-60327-389-3_1
[30]   Compound X increases heart weight: Ultrasound and telemetry evaluation in the rat [J].
Ju, Haisong ;
Hershman, Kenneth ;
Zhao, Shufang ;
LaDuke, Carrie ;
Williamsb, Lee ;
Carey, Cynthia ;
Friedrichs, Gregory .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2015, 75 :174-174