Stereoselective pharmacokinetic study of epiprogoitrin and progoitrin in rats with UHPLC-MS/MS method

被引:2
|
作者
Xu, Yan [1 ]
Li, Jinhang [1 ]
Shi, Yanhong [2 ]
Yang, Li [3 ,4 ]
Wang, Zhengtao [4 ]
Han, Han [1 ,5 ]
Wang, Rui [1 ]
机构
[1] Shanghai Univ Tradit Chinese Med, Sch Pharm, Shanghai 201203, Peoples R China
[2] Shanghai Univ Tradit Chinese Med, Inst TCM Int Standardizat, Shanghai 201203, Peoples R China
[3] Shanghai Univ Tradit Chinese Med, Inst Interdisciplinary Integrat Med Res, Shanghai 201203, Peoples R China
[4] Shanghai Univ Tradit Chinese Med, Inst Chinese Mat Med, MOE Key Lab Standardizat Chinese Med, Shanghai 201203, Peoples R China
[5] Shanghai Univ Tradit Chinese Med, Expt Ctr Teaching & Learning, Shanghai 201203, Peoples R China
基金
中国国家自然科学基金;
关键词
Epiprogoitrin; Progoitrin; Pharmacokinetics; Stereospecific; LC-MS/MS; PERFORMANCE LIQUID-CHROMATOGRAPHY; ISATIS-INDIGOTICA; AMERICAN GINSENG; RG(3) EPIMERS; RG3; EPIMERS; EXTRACT; 20(S); RH2;
D O I
10.1016/j.jpba.2020.113356
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An accurate and precise liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for the pharmacokinetic study of epiprogoitrin and progoitrin, a pair of epimers that can be deglycosylated to epigoitrin and goitrin, respectively. These analytes were administered intravenously or intragastrically to male Sprague-Dawley rats, and the influence of 3(R/S)-configuration on the pharmacokinetics of both epimers in rat plasma was elucidated. The analytes and an internal standard (i.e., sinigrin) were resolved by LC-MS/MS on a reverse-phase ACQUITY UPLC (TM) HSS T3 column equilibrated and eluted with acetonitrile and water (0.1 % formic acid) at a flow rate of 0.3 mL/min. Quantitation was achieved by applying the multiple reaction monitoring mode, in the negative ion mode, at transitions of m/z 388 -> 97 and m/z 358 -> 97 for the epimers and sinigrin, respectively. The method demonstrated good linearity over the concentration range of 2-5000 ng/mL (r > 0.996). The lower limit of quantification for epiprogoitrin and progoitrin was 2 ng/mL. The interday and intraday accuracy and precision were within +/- 15 %. The extraction recovery, stability, and matrix effect were demonstrated to be within acceptable limits. The validated method was thus successfully applied for the pharmacokinetic study of both the epimers. After the rats received the same oral dose of the epimers, the pharmacokinetic profiles were similar. The maximum plasma concentration (C-max) and AUC values of epiprogoitrin were a bit higher than those of progoitrin, whereas the pharmacokinetic behaviours of the epimers were obviously different upon intravenous administration. The C-max and AUC values of epiprogoitrin were approximately three-fold higher than those of progoitrin, and the half-life of progoitrin was much shorter than that of epiprogoitrin. The oral bioavailability of progoitrin was 20.1 %-34.1 %, which is three times higher than that of epiprogoitrin. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A UHPLC-MS/MS Method for the Quantitation of Olmutinib in Rat Plasma
    Bao, Su-su
    Wen, Jian
    Liu, Teng-hui
    Zhang, Bo-wen
    Wang, Chen-chen
    Hu, Guo-xin
    ACTA CHROMATOGRAPHICA, 2019, 31 (02) : 105 - 108
  • [32] A UHPLC-MS/MS Method Reveals the Pharmacokinetics of Deacetyl Asperulosidic Acid Methyl Ester in Rats
    Guan, Huida
    Chen, Jian
    Yin, Hao
    Feng, Xia
    Liu, Chang
    Liu, Shanshan
    Li, Jiacheng
    Li, Jingchu
    Cao, Yongbing
    Ma, Chao
    BIOMEDICAL CHROMATOGRAPHY, 2025, 39 (03)
  • [33] Quantification of pravastatin acid, lactone and isomers in human plasma by UHPLC-MS/MS and its application to a pediatric pharmacokinetic study
    van Haandel, Leon
    Gibson, Kim T.
    Leeder, J. Steven
    Wagner, Jonathan B.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1012 : 169 - 177
  • [34] Determination of multicomponents from Zhuanggu Guanjie Capsule in rat plasma by UHPLC-MS/MS and pharmacokinetic study
    Cheng, Liyuan
    Zhang, Xiaoying
    Qi, Jige
    Zhang, Yue
    Zhou, Kun
    BIOANALYSIS, 2023, 15 (10) : 537 - 551
  • [35] A Validated UHPLC-MS/MS Method for Determination of Nalbuphine in Human Plasma and Application for Pharmacokinetic Study of Patients Undergoing General Anesthesia
    Gao, Xiaonan
    Nie, Xuyang
    Gao, Jinglin
    Heng, Tianfang
    Zhang, Yuqi
    Hua, Li
    Sun, Yaqi
    Feng, Zhangying
    Jia, Li
    Wang, Mingxia
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2023, 61 (08) : 758 - 765
  • [36] A rapid UHPLC-MS/MS method for the quantification of ARQ531 in rat plasma: Validation and its application to a pharmacokinetic study
    Liu, Jizhen
    Ji, Musi
    Li, Zhidong
    Xu, Xun
    Li, Lili
    Li, Huawen
    Tian, Yuguang
    Su, Xiaohua
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (11)
  • [37] Preliminary pharmacokinetic study of the anticancer 6BIO in mice using an UHPLC-MS/MS approach
    Tchoumtchoua, Job
    Halabalaki, Maria
    Gikas, Evangelos
    Tsarbopoulos, Anthony
    Fotaki, Nikoletta
    Liu, Lucy
    Nam, Sangkil
    Jove, Richard
    Skaltsounis, Leandros A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 164 : 317 - 325
  • [38] UHPLC-MS/MS method for simultaneous determination of Radix Polygalae glycolipids and organic acids in rat plasma and application in a pharmacokinetic study
    Xu, Baoxin
    Qu, Congcong
    Zheng, Wenhua
    Xi, Yaya
    Zhao, Xin
    Li, Huifen
    Liu, Jiangting
    Zhang, Xuelan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1100 : 165 - 173
  • [39] Development and Validation of a UHPLC-MS/MS Method for the Quantification of a Novel PYGB Inhibitor in Plasma: Application to Pharmacokinetic Studies
    Xu, Sumei
    Li, Shuai
    Yan, Zhiwei
    Wang, Youde
    Zhang, Liying
    MOLECULES, 2023, 28 (19):
  • [40] Method development and validation for acrylamide in potato cutlet by UHPLC-MS/MS
    Kumari, Alka
    Bhattacharya, Bhaswati
    Agarwal, Tripti
    Paul, Vijay
    Maurya, Vaibhav Kumar
    Chakkaravarthi, S.
    Simal-Gandara, J.
    FOOD CONTROL, 2023, 151