Forward flexed posture: reliability and determinants of tragus-to-wall measurement

被引:6
|
作者
Tudini, Frank T. [1 ]
Myers, Bradley J. [1 ]
Bohannon, Richard W. [1 ]
机构
[1] Campbell Univ, Coll Pharm & Hlth Sci, Phys Therapy, 4150 US HWY 421 South, Buies Creek, NC 27506 USA
关键词
Neck; posture; strength; measurement;
D O I
10.1080/09593985.2020.1771801
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Introduction Forward flexed posture is an impairment in body structure commonly seen among older adults and those with pathologies such as ankylosing spondylitis and osteoporosis. Accurate measurement of forward flexed posture is important as it is related to pain, mobility limitations, and falls. Our purpose was to examine the reliability and determinants of forward flexed posture as indicated by tragus-to-wall (TTW) distance Methods Twenty healthy younger and 20 healthy older adults were included in this secondary analysis of data from a neck strength study. Measurements included the linear distance of TTW standing naturally and with neck retraction, age, gender, body mass index (BMI), and neck retraction strength. Measurements were performed initially by 2 investigators and by the primary investigator 1 week later. Intraclass correlation coefficients (ICCs) (model 3,1) described relative reliability and Bland-Altman plots characterized absolute reliability. A mixed general linear model examined the determinants for TTW distance Results Good inter-rater (ICC = 0.811-0.878) and test-retest reliability (ICC = 0.853-0.862) were found in both positions. Bland-Altman plots showed that absolute limits of agreement ranged from - 1.9 to +3.8 cm for inter-rater reliability and -2.4 to +2.6 cm for test-retest reliability. Analysis of TTW determinants demonstrated significant differences between neck positions, dichotomous age groups, and BMI groups (p <= 0.001). There was no significant difference based on neck strength. Conclusions Our results indicate that TTW distance, measured using a standardized procedure, is a reliable method of quantifying forward flexed posture. TTW distance is greater in relaxed standing, older individuals, and those with greater BMI.
引用
收藏
页码:579 / 586
页数:8
相关论文
共 50 条
  • [31] The short-term reliability of grip strength measurement and the effects of posture and grip span
    Watanabe, T
    Owashi, K
    Kanauchi, Y
    Mura, N
    Takahara, M
    Ogino, T
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (03): : 603 - 609
  • [32] Reliability of scapular position and periscapular muscle strength tests in healthy subjects with forward neck and rounded shoulder posture
    Kim, Tae-Gyu
    Kim, Jun-Seok
    Zhang, Haimin
    Kim, Soo-Yong
    ISOKINETICS AND EXERCISE SCIENCE, 2024, 32 (03) : 265 - 272
  • [33] Reliability Investigation of A Novel Custom-made Body Posture and Spinal Curve Measurement System
    Wang, Shih-Ting
    Hsu, Yu-Chi
    Yeh, Yi-Hsuan
    Yu, Yu-Lin
    Yang, Chich-Haung
    Guo, Lan-Yuen
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 335 - 335
  • [34] The Reliability and Validity of Upper Quadrant Posture and Two-dimensional Range of Motion Measurement Tools
    van Niekerk, S.
    Louw, Q.
    SOUTH AFRICAN JOURNAL OF PHYSIOTHERAPY, 2008, 64 (03) : 12 - 18
  • [35] Reliability and measurement error of the BioTonix video posture evaluation system - Part 1: Inanimate objects
    Normand, MC
    Harrison, DE
    Cailliet, R
    Black, P
    Harrison, DD
    Holland, B
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2002, 25 (04) : 246 - 250
  • [36] Measurement of craniovertebral angle by the Modified Head Posture Spinal Curvature Instrument: A reliability and validity study
    Subbarayalu, Arun Vijay
    PHYSIOTHERAPY THEORY AND PRACTICE, 2016, 32 (02) : 144 - 152
  • [37] Reliability and Reproducibility of Chest Wall Expansion Measurement in Young Healthy Adults
    Debouche, Sophie
    Pitance, Laurent
    Robert, Annie
    Liistro, Giuseppe
    Reychler, Gregory
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2016, 39 (06) : 443 - 449
  • [38] Reliability of lateral wall-thickness measurement in trochanteric fractures and parameters associated with lateral wall integrity
    Ratanakornphan, Chindarat
    Pikulhom, Thanachart
    Jenvorapoj, Somjet
    Amarase, Chavarin
    Tantavisut, Saran
    ASIAN BIOMEDICINE, 2024, 18 (01) : 24 - 29
  • [39] Real-Time Forward Head Posture Detection and Correction System Utilizing an Inertial Measurement Unit Sensor
    Park, Gyumin
    Jung, Im Y.
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [40] Photographic measurement of upper-body sitting posture of high school students: A reliability and validity study
    van Niekerk, Sjan-Mari
    Louw, Quinette
    Vaughan, Christopher
    Grimmer-Somers, Karen
    Schreve, Kristiaan
    BMC MUSCULOSKELETAL DISORDERS, 2008, 9 (1)