Development and Comparison of Analytical Methods for Measuring Simazine Herbicide Using Gas Chromatography/Ion Trap, Gas Chromatography/Mass Selective Detector, and High Performance Liquid Chromatography/Triple Quadrupole Mass Spectrometers

被引:5
作者
Chung, Ill-Min [2 ]
Park, Inmyoung [3 ,4 ]
Kim, Seung-Hyun [1 ]
机构
[1] Republ Korea Res Inst Stand & Sci, Div Metrol Qual Life, Ctr Analyt Chem, Yuseong 305600, Dajeon, South Korea
[2] Konkuk Univ, Dept Appl Life Sci, Coll Life & Environm Sci, Seoul 143701, South Korea
[3] Seoul Natl Univ, Dept Agr Biotechnol, Seoul 151921, South Korea
[4] Seoul Natl Univ, Ctr Agr Biomat, Seoul 151921, South Korea
来源
JOURNAL OF THE KOREAN SOCIETY FOR APPLIED BIOLOGICAL CHEMISTRY | 2011年 / 54卷 / 05期
关键词
detection limit; gas chromatography/ion-trap; gas chromatography/mass selective detector; high performance liquid chromatography/triple quadrupole mass spectrometers; quantification limit; simazine; SOLID-PHASE EXTRACTION; WATER; PESTICIDES; ATRAZINE; SAMPLES; MICROCONTAMINANTS; RESIDUES; SOIL;
D O I
10.3839/jksabc.2011.112
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Simazine is widely used to manage weed growth in the agricultural and industrial fields. Three analytical methods, including gas chromatography (GC)/ion-trap (IT), GC/mass selective detector (MSD), and high-performance liquid chromatography (HPLC)/triple quadrupole mass spectrometers (HPLC/MS/MS), were developed and compared for simazine quantification. The spike recoveries by GC/IT, GC/MSD, and HPLC/MS/MS were 100, 117, and 82.5%, respectively. Different spike recovery depending on analytical methods could be due to matrix effect, different instrumental sensitivity, losses during sample preparation or all of the above. The limit of detection was 0.0361, 0.0263, and 0.0013 mg/kg by GC/IT, GC/MSD, and HPLC/MS/MS, respectively. The HPLC/MS/MS with a positive atmospheric pressure chemical ionization (APCI) ionization mode was the most rapid (7 min), sensitive (limit of detection: 0.0013 mg/kg, limit of quantification: 0.0042 mg/kg), and precise (relative standard deviation: 0.5%) method for simazine quantification.
引用
收藏
页码:744 / 749
页数:6
相关论文
共 50 条
  • [41] Determination of Antibiotics in Vegetables Using QuEChERS-Based Method and Liquid Chromatography-Quadrupole Linear Ion Trap Mass Spectrometry
    He, Zeying
    Wang, Yuehua
    Xu, Yaping
    Liu, Xiaowei
    FOOD ANALYTICAL METHODS, 2018, 11 (10) : 2857 - 2864
  • [42] Analysis of Halogenated Polycyclic Aromatic Hydrocarbons in Soil Samples Using Gas Chromatography Coupled with Triple Quadrupole Mass Spectrometry
    Zhang Z.-R.
    Jin R.
    Zhou X.
    Qi Z.-Y.
    Liu G.-R.
    Zheng M.-H.
    Journal of Chinese Mass Spectrometry Society, 2023, 44 (02) : 299 - 313
  • [43] Removal of pesticides from strawberries using plant extracts and assessed by gas chromatography-triple quadrupole mass spectrometry
    Renuka, Venkatachalapathy
    Ramachandran, Anoop Chandra Indira
    Babu, PackirisamyAzhagu Saravana
    Das, Somnath
    Peter, Maria Jenita
    Udhyasooriyan, Lalitha Priya
    Senthilnathan, Karthikeyan
    Sukumar, Muthusamy
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (18) : 6720 - 6731
  • [44] An improved gas chromatography screening method for doping substances using triple quadrupole mass spectrometry, with an emphasis on quality assurance
    De Brabanter, Nik
    Van Gansbeke, Wim
    Geldof, Lore
    Van Eenoo, Peter
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (11) : 1416 - 1435
  • [45] Rapid determination of sildenafil and its analogues in dietary supplements using gas chromatography-triple quadrupole mass spectrometry
    Mokhtar, S. U.
    Chin, S. -T.
    Kee, C. -L.
    Low, M. -Y.
    Drummer, O. H.
    Marriott, P. J.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 121 : 188 - 196
  • [46] Determination of 17 Plant Growth Regulator Residues by Ultra-High Performance Liquid Chromatography-Triple Quadrupole Linear Ion Trap Mass Spectrometry Based on Modified QuEChERS Method
    Cao, Shurui
    Zhou, Xue
    Li, Xianliang
    Tang, Bobin
    Ding, Xiaowen
    Xi, Cunxian
    Hu, Jiangtao
    Chen, Zhiqiong
    FOOD ANALYTICAL METHODS, 2017, 10 (09) : 3158 - 3165
  • [47] Determination of sixteen pyrethroids in water using dispersive liquid-liquid microextraction based on dissolved carbon dioxide flotation after emulsification microextraction using gas chromatography with triple quadrupole mass spectrometry
    Ye, Jingqing
    Yao, Zhoulin
    Wang, Zhiwei
    Nie, Jing
    Li, Zuguang
    ANALYTICAL METHODS, 2016, 8 (32) : 6194 - 6201
  • [48] Determination of pendimethalin in water, sediment, and Procambarus clarkii by high performance liquid chromatography-triple quadrupole mass spectrometry
    Qiuhong Yang
    Xiaohui Ai
    Siqi Li
    Huan Liu
    Yongtao Liu
    Environmental Monitoring and Assessment, 2019, 191
  • [49] Multiresidue Method for the Determination of Pesticides in Fruits and Vegetables Using Gas Chromatography-Negative Chemical Ionization-Triple Quadrupole Tandem Mass Spectrometry
    Dong, Jing
    Pan, Yu-Xiang
    Lv, Jian-Xia
    Sun, Jun
    Gong, Xiao-Ming
    Li, Kai
    CHROMATOGRAPHIA, 2011, 74 (1-2) : 109 - 119
  • [50] Determination of tetrabromobisphenol-A in soil by high performance liquid chromatography-electrospray ion trap mass spectrometry
    Peng Hao
    Jin Jun
    Wang Ying
    Liu Wei-Zhi
    Yang Ruo-Ming
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (04) : 549 - 551