Home network power-line communication signal processing based on wavelet packet analysis

被引:90
作者
He, HB [1 ]
Cheng, SJ
Zhang, YB
Nguimbis, J
机构
[1] Ohio Univ, Sch Elect Engn & Comp Sci, Dept Elect Engn, Athens, OH 45701 USA
[2] Huazhong Univ Sci & Technol, Dept Elect Engn, Wuhan 430074, Peoples R China
关键词
noise; power-line communication; signal processing; wavelet packet transform; wavelet transform;
D O I
10.1109/TPWRD.2004.843489
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recent advances in signal processing methodologies have spawned the way for a high-speed home network power-line communication (PLC) system. In this paper, a novel signal processing method based. on wavelet packet analysis is proposed to combat the adverse communication environment over power lines. A comparison research between wavelet transform and wavelet packet transform is presented. Since wavelet packet decomposition can provide more precise frequency resolution than wavelet decomposition, this paper proposes to use the wavelet packet analysis to deal with the highly polluted PLC communication signal. A hardware structure for the PLC system is presented as an experimental platform for sampling an actual communication signal. Simulation results based on these kinds of actual communication signals show the effectiveness of the proposed method.
引用
收藏
页码:1879 / 1885
页数:7
相关论文
共 13 条
[1]   ENTROPY-BASED ALGORITHMS FOR BEST BASIS SELECTION [J].
COIFMAN, RR ;
WICKERHAUSER, MV .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1992, 38 (02) :713-718
[2]   Narrowband, low data rate communications on the low-voltage mains in the CENELEC frequencies - Part I: Noise and attenuation [J].
Cooper, D ;
Jeans, T .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (03) :718-723
[3]  
Dai HY, 2003, IEEE COMMUN MAG, V41, P100, DOI 10.1109/MCOM.2003.1200108
[4]  
Daubechies I, 1993, P S APPL MATH, P1
[5]   Analysis of reflection of signal transmitted in low-voltage powerline with complex wavelet [J].
He, HB ;
Cheng, SJ ;
Zhang, YB ;
Nguimbis, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :86-91
[6]   A novel scheme for low voltage powerline communication signal processing [J].
Jiang, X ;
Nguimbis, J ;
Cheng, S ;
He, H ;
Wu, X .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2003, 25 (04) :269-274
[7]   Attenuation characteristics of high rate home-networking PLC signals [J].
Kim, CJ ;
Chouikha, MF .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (04) :945-950
[8]  
MALLAT S, 1989, IEEE T PATTERN ANAL, V11, P7
[9]  
Nguimbis J, 2000, 2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, P2035, DOI 10.1109/PESW.2000.847666
[10]  
Papaleonidopoulos IC, 2003, IEEE T CONSUM ELECTR, V49, P89, DOI 10.1109/TCE.2003.1205460