Application of out-of-step relaying for small generators in distributed generation

被引:15
|
作者
Malmedal, K
Sen, PK
Nelson, JP
机构
[1] NEI Elect Power Engn Inc, Wheat Ridge, CO 80001 USA
[2] Colorado Sch Mines, Golden, CO 80402 USA
关键词
Device; 78; distributed generation; generator protection; out-of-step relay;
D O I
10.1109/TIA.2005.857470
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The recent popularity of distributed generation (DG) has caused an increasing number of small generators (rated between 100 kVA and 12.5 MVA) to be connected to the power system at the distribution level (480 V to 11.47 kV). Some utilities require that out-of-step relays be installed by the generation owner at the point of common coupling (PCC). This paper will examine out-of-step relaying. practices as they apply to small generation protection. It will consider the value, purpose, and applicability and provide guidelines for setting of this type of relay when employed.
引用
收藏
页码:1506 / 1514
页数:9
相关论文
共 50 条
  • [21] The Concept of the Problem Solution of Estimation of the Impact of Wind Power Generators on the Out-of-Step Protection Operation
    Ruban, Nikolay
    Askarov, Alisher
    Razzhivin, Igor
    THERMOPHYSICAL BASIS OF ENERGY TECHNOLOGIES (TBET 2019), 2020, 2212
  • [22] Configuration of large-scale power system out-of-step separation considering minor out-of-step generations
    NARI Relays Electric Co. Ltd., Nanjing 211100, China
    不详
    Dianli Xitong Zidonghue, 2006, 17 (50-53+107):
  • [23] Out-of-step protection fundamentals and advancements
    Tziouvaras, DA
    Hou, DQ
    2004 57TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2004, : 282 - 307
  • [24] Out-of-step protection with AI methods
    Rebizant, W
    Feser, K
    SEVENTH INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN POWER SYSTEM PROTECTION, 2001, (479): : 295 - 298
  • [25] Out-of-Step Relays Testing Procedure
    Sauhats, Antans
    Utans, Andrejs
    Pashnin, Gregory
    Antonovs, Dmitrijs
    ELECTRICAL CONTROL AND COMMUNICATION ENGINEERING, 2011, 28 (01) : 9 - 14
  • [26] Automatic Tuning of Out-of-Step Relays
    Cole, Stijn
    Promel, Francois
    Josz, Pierre
    Merckx, Christian
    Karoui, Karim
    Rese, Leonardo
    2016 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON), 2016,
  • [27] Application guidelines for induction generators for distributed generation
    Sen, PK
    Nelson, JP
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59, I AND II, 1997, 59 : 1160 - 1165
  • [28] Application guidelines for induction generators for distributed generation
    Sen, PK
    Nelson, JP
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59 - PTS I AND II, 1997, 59 : 1160 - 1165
  • [29] Out-of-step detection of synchronous generators using dual computational techniques based on correlation and instantaneous powers
    Mahmoud, Ragab Abd Allah
    Malik, Om Parkash
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (13) : 2716 - 2746
  • [30] Application of Equal Area Criterion Conditions in the Time Domain for Out-of-Step Protection
    Paudyal, Sumit
    Ramakrishna, Gokaraju
    Sachdev, Mohindar S.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) : 600 - 609