Application of out-of-step relaying for small generators in distributed generation

被引:15
|
作者
Malmedal, K
Sen, PK
Nelson, JP
机构
[1] NEI Elect Power Engn Inc, Wheat Ridge, CO 80001 USA
[2] Colorado Sch Mines, Golden, CO 80402 USA
关键词
Device; 78; distributed generation; generator protection; out-of-step relay;
D O I
10.1109/TIA.2005.857470
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The recent popularity of distributed generation (DG) has caused an increasing number of small generators (rated between 100 kVA and 12.5 MVA) to be connected to the power system at the distribution level (480 V to 11.47 kV). Some utilities require that out-of-step relays be installed by the generation owner at the point of common coupling (PCC). This paper will examine out-of-step relaying. practices as they apply to small generation protection. It will consider the value, purpose, and applicability and provide guidelines for setting of this type of relay when employed.
引用
收藏
页码:1506 / 1514
页数:9
相关论文
共 50 条
  • [1] Fuzzy logic application to out-of-step protection of generators
    Rebizant, W
    Feser, K
    2001 POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2001, : 927 - 932
  • [2] The out-of-step protection with prediction function for generators
    Bi, DQ
    Wang, XH
    Xu, ZY
    Wang, WJ
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 127 - 130
  • [3] Relays for out-of-step tripping of generators for Symposium Proceedings
    Vargoncik, Michal
    PROCEEDINGS OF THE IVTH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRIC POWER ENGINEERING - ELEKTROENERGETIKA 2007, 2007, : 517 - 518
  • [4] Power Swing Relaying in the Texas Panhandle - An Out-Of-Step Odyssey
    Jones, Kevin W.
    2015 68TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2015, : 1 - 16
  • [5] Neural networks using apparent resistance for out-of-step relaying
    Hayes, KF
    Rovnyak, SM
    Sun, LY
    Khaliq, A
    Thyagarajan, S
    2002 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2002, : 459 - 463
  • [6] Out-of-step conditions in the two-machine system with increased share of distributed generation
    Svalova, Inesa
    Svalovs, Andrejs
    ECT 2007: ELECTRICAL AND CONTROL TECHNOLOGIES, PROCEEDINGS, 2007, : 86 - +
  • [7] OUT OF STEP RELAYING FOR GENERATORS WORKING GROUP REPORT
    IMHOF, JA
    BERDY, J
    ELMORE, WA
    GOFF, LE
    NEW, WC
    PARR, GC
    SUMMERS, AH
    WAGNER, CL
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (05): : 1556 - 1564
  • [8] Application of out-of-step relaying systems with wavelet transform on the KEPCO 765kV power system
    Jang, SI
    Park, SK
    Shin, MC
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 329 - 334
  • [9] Out-of-step protection modeling for playback testing applied to industrial generators
    Celeita, David
    Gutierrez, Mario
    Toro, Mateo
    Ramos, Gustavo
    2018 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2018,
  • [10] 'HONOURABLE OUT-OF-STEP'
    BAYSTON, M
    DANCING TIMES, 1976, 66 (788): : 419 - 419