Automatic Striatal ROI Delineation for Semi-quantitative Analysis of 99mTc-TRODAT-1 Brain SPECT Imaging

被引:2
作者
Yang, Bang-Hung [1 ,2 ,3 ]
Lin, Kang-Ping [4 ,5 ]
Chen, Mei-Fen [4 ,5 ]
Weng, Jui-Hung [6 ]
Kao, Pan-Fu [6 ]
Lin, Wen-Chen [4 ,5 ]
Liu, Ren-Shyan [1 ,2 ,3 ,7 ]
机构
[1] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
[2] Taipei Vet Gen Hosp, Dept Nucl Med, Taipei, Taiwan
[3] Taipei Vet Gen Hosp, Natl PET Cyclotron Ctr, Taipei, Taiwan
[4] Chung Yuan Christian Univ, Technol Translat Ctr Med Device, Taoyuan, Taiwan
[5] Chung Yuan Christian Univ, Dept Elect Engn, Taoyuan, Taiwan
[6] Chung Shan Med Univ Hosp, Dept Nucl Med, Taichung, Taiwan
[7] Cheng Hsin Gen Hosp, Dept Nucl Med, Taipei, Taiwan
关键词
Automatic ROI delineation; Specific uptake ratio analysis; SPECT imaging; Parkinson's disease; PARKINSONS-DISEASE; DOPAMINE TRANSPORTERS; QUANTIFICATION; PET; BINDING;
D O I
10.1007/s40846-020-00530-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Single-photon emission computed tomography (SPECT) imaging, a relatively inexpensive nuclear imaging technique, has been used as a diagnostic tool for Parkinson's disease (PD). The tracer Tc-99m-TRODAT-1 is commonly used in Taiwan, where the imaging cost is covered under the national health insurance system. However, poor TRODAT-SPECT imaging resolution is a problem. Therefore, we developed a semi-quantitative program that can perform automatic region of interest (ROI) delineation for semi-quantifying striatal dopamine transporter activities. Methods A total of 228 subjects were enrolled in this study, including PD patients (n = 62) and healthy controls (n = 166). The subjects received a Tc-99m-TRODAT-1 brain SPECT scan. Some of the subjects (n = 40) also received a high-resolution magnetic resonance imaging (MRI) scan for the evaluation of the accuracy of the semi-quantitative assessment. In addition, the developed automatic ROI delineation method was used to calculate the striatal specific uptake ratio (SUR) in dopamine transporter imaging. The reproducibility of the SUR obtained using the method was compared to those in previous studies. Results Based on linear regression analysis (r(2) = 0.92, correlation coefficient = 0.96), a correlation was found between the results obtained using the automatic ROI delineation method and those of the manual method in striatum with the corresponding MR images. The age-related decline of SUR availability measured in this study was 6.4% per decade. There was almost no difference between our results and those in related clinical studies. Conclusions The proposed automatic ROI delineation program for SUR analysis was tested and used to estimate the ROIs in TRODAT-SPECT images to aid PD diagnosis. The program could be helpful for physicians who are inexperienced with TRODAT-SPECT images.
引用
收藏
页码:428 / 439
页数:12
相关论文
共 27 条
[1]   PET and SPECT functional imaging in Parkinson's disease [J].
Antonini, A ;
DeNotaris, R .
SLEEP MEDICINE, 2004, 5 (02) :201-206
[2]   IBZM tool: a fully automated expert system for the evaluation of IBZM SPECT studies [J].
Buchert, Ralph ;
Berding, Georg ;
Wilke, Florian ;
Martin, Brigitte ;
von Borczyskowski, Daniel ;
Mester, Janos ;
Brenner, Winfried ;
Clausen, Malte .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (09) :1073-1083
[3]   The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation [J].
Calvini, Piero ;
Rodriguez, Guido ;
Inguglia, Fabrizio ;
Mignone, Alessandro ;
Guerra, Ugo Paolo ;
Nobili, Flavio .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (08) :1240-1253
[4]   Diagnostic accuracy of [99mTc]TRODAT-1 SPECT imaging in early Parkinson's disease [J].
Chou, KL ;
Hurtig, HI ;
Stern, MB ;
Colcher, A ;
Ravina, B ;
Newberg, A ;
Mozley, PD ;
Siderowf, A .
PARKINSONISM & RELATED DISORDERS, 2004, 10 (06) :375-379
[5]   Diagnostic criteria for Parkinson disease [J].
Gelb, DJ ;
Oliver, E ;
Gilman, S .
ARCHIVES OF NEUROLOGY, 1999, 56 (01) :33-39
[6]  
Habraken JBA, 1999, J NUCL MED, V40, P1091
[7]  
Huang WS, 2001, J NUCL MED, V42, P1303
[8]  
Huang WS, 2003, J NUCL MED, V44, P999
[9]  
Hwang WJ, 2004, J NUCL MED, V45, P207
[10]   Usefulness of the frontal lobe bottom and cerebellum tuber vermis line as an alternative clue to set the axial angle parallel to the AC-PC line in I-123 IMP SPECT imaging: a retrospective study [J].
Inokuchi, Yasuhiro ;
Koya, Saki ;
Uematsu, Masahiro ;
Takashina, Tsuneyuki .
RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (04) :388-392