Preliminary study on fire protection of window glass by water mist curtain

被引:12
|
作者
Wang, Xishi [1 ]
Tan, Qiong [1 ,2 ]
Wang, Zhigang [1 ]
Kong, Xiangxiao [1 ]
Cong, Haiyong [1 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[2] Operat & Monitoring Ctr Hefei Urban Safety & Secu, Hefei 230601, Anhui, Peoples R China
关键词
Building fire; Water mist curtain; Radiant heat attenuation; Window glass; INDUCED THERMAL FIELDS; HEAT-RESISTANCE; FILM; PANE; TEMPERATURE; ATTENUATION; RADIATION; SPRINKLER; BREAKING;
D O I
10.1016/j.ijthermalsci.2017.11.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
Glass may easily break during a fire that can significantly accelerate the enclosure fire development. Water mist, as an efficient fire suppression technique, has been used for fire protection of an object due to fire radiant heat attenuation. The main purpose of this work is to investigate the behavior of the window glass heated by a fire and protected by a water mist curtain (WMC). Float glass with a dimension of 600 x 600 x 6 mm(3) exposed to a 0.16 MW gas fire was tested. The WMC was generated by a single orifice nozzle with K-factor of 1.01 L/min/ MPa1/2. The initial time of glass breakage, the temperature difference of the glass pane and the heat flux penetrating through the glass were measured and compared. The time of the window glass pane maintaining its integrated structure under the protection of WMC extends to more than 600 s comparing to 150 s of that without the protection of WMC. More than 38.5% thermal radiation of the fire would be attenuated by the WMC with thickness of 0.075 m and operating pressure of 1.0 MPa. The WMC demonstrates a better cooling capacity that can protect the glass from breakage more effectively comparing to water film with same flow rate. It is also found that the delaying of the activation of the WMC system contributes little to the crack or fallout of the float glass. The results may be helpful for providing guidelines on keeping glass integration in building fire scenarios.
引用
收藏
页码:44 / 51
页数:8
相关论文
共 50 条
  • [41] Study on fire extinguishing performance of ultrafine water mist in a cup burner
    LIANG TianShui LIAO GuangXuan LU SiuMing WANG XiShi State Key Laboratory of Fire ScienceUniversity of Science and Technology of ChinaHefei China Department of Building and ConstructionCity University of Hong KongKowloonHong KongSAR China
    Science China(Technological Sciences), 2012, 55 (07) : 1982 - 1987
  • [42] Study on fire extinguishing performance of ultrafine water mist in a cup burner
    LIANG TianShui 1
    2 Department of Building and Construction
    Science China(Technological Sciences), 2012, (07) : 1982 - 1987
  • [43] Study on fire extinguishing performance of ultrafine water mist in a cup burner
    TianShui Liang
    GuangXuan Liao
    SiuMing Lu
    XiShi Wang
    Science China Technological Sciences, 2012, 55 : 1982 - 1987
  • [44] Experimental study on suppressing PVC fire with water mist in a confined space
    Liu, Jianghong
    Qin, Jun
    Huang, Xin
    Liao, Guangxuan
    POLYMER DEGRADATION AND STABILITY, 2007, 92 (05) : 747 - 751
  • [45] Experimental Study on Wood Crib Fire Suppression of Water Mist with additives
    Cui Yongyi
    Qu Fang
    Cui, Fanlin
    Jun, Zhang
    2013 FOURTH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND ENGINEERING APPLICATIONS, 2013, : 305 - 308
  • [46] Experimental and numerical study of pool fire suppression using water mist
    Jenft, A.
    Collin, A.
    Boulet, P.
    Pianet, G.
    Breton, A.
    Muller, A.
    FIRE SAFETY JOURNAL, 2014, 67 : 1 - 12
  • [47] Experimental study on extinguishing pool fire sheltered by barrier with water mist
    Jianghong, Liu
    Yudong, Fang
    Guangxuan, Liao
    Lin, Lin
    Journal of Applied Fire Science, 2003, 12 (03): : 209 - 222
  • [48] Assessment of fire protection performance of water mist applied in exhaust ducts for semiconductor fabrication process
    Shu, YL
    Jeng, WJ
    Chiu, CW
    Chen, CH
    FIRE AND MATERIALS, 2005, 29 (05) : 295 - 302
  • [49] A SIMULATED STUDY ON THE EFFECT OF WATER TEMPERATURE ON COOLING EFFICIENCY OF WATER MIST FIRE EXTINGUISHERS
    Omidvar, Amir
    Mandavi, Amirhossein
    Mehryar, Reza
    JOURNAL OF THERMAL ENGINEERING, 2020, 6 (04): : 460 - 473
  • [50] SHIELDING OF FIRE RADIATION WITH THE USE OF MULTI-LAYERED WATER MIST CURTAINS: PRELIMINARY ESTIMATES
    Dombrovsky, Leonid A.
    Dembele, Siaka
    Wen, Jennifer X.
    COMPUTATIONAL THERMAL SCIENCES, 2016, 8 (04): : 371 - 380