Interobserver Agreement on the Endosonographic Features of Lymph Nodes in Aerodigestive Malignancies

被引:8
作者
de Melo, Silvio W., Jr. [1 ]
Panjala, Chakri [1 ]
Crespo, Sergio [1 ]
Diehl, Nancy N. [2 ]
Woodward, Timothy A. [1 ]
Raimondo, Massimo [1 ]
Wallace, Michael B. [1 ]
机构
[1] Mayo Clin Florida, Dept Internal Med, Div Gastroenterol & Hepatol, Jacksonville, FL 32224 USA
[2] Mayo Clin Florida, Biostat Unit, Jacksonville, FL 32224 USA
关键词
Inter-observer agreement; Endoscopic ultrasound; Fine-needle aspiration; Endosonographic feature; Malignant lymph node; FINE-NEEDLE-ASPIRATION; CELL LUNG-CANCER; ENDOSCOPIC ULTRASOUND; EUS; ACCURACY; LYMPHADENOPATHY; DIAGNOSIS; METASTASIS; INVASION; BENIGN;
D O I
10.1007/s10620-011-1725-8
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Endoscopic ultrasound (EUS) is used to locally stage aerodigestive malignancies. Endosonographic features are used to predict malignant lymph nodes (MLN). Interobserver agreement on the endosonographic features of MLN has not been described. Aims To evaluate the interobserver agreement among endosonographers on the EUS features of MLN in aerodigestive malignancies along with the specific feature used to make this distinction. Methods A total of 760 procedures of suspected LN were reviewed. Cases were selected based on cytology-proven malignant or benign LN involvement by FNA with correspondent photodocumentation. Images of each LN were de-identified and distributed to three expert endosonographers. The experts recorded the LN's echogenicity (hypoechoic or other), shape (round or other), border (sharp or fuzzy) and subjective diagnosis (benign or malignant). The relationship between the endosonographers' subjective as well as the pathological diagnosis and LN's endosonographic features were analyzed using logistic regression analysis. Pair-wise comparison between endoscopist and interobserver agreement (kappa statistics) were performed. Results Images of 41 malignant and 35 benign LN were evaluated. There was fair agreement on shape, Ie = 0.35 (95% CI 0.2-0.5), and moderate agreement on echogenicity and borders, Ie = 0.46 (95% CI 0.31-0.61) and 0.43 (95% CI 0.27-0.58) respectively. The agreement on malignant LN was good, Ie = 0.65 (95% CI 0.5-0.8). The overall diagnostic predictive accuracy ranged from 70 to 77% among the three endoscopists.Two of the three endoscopists assessed shape as the most predictive feature of malignancy (OR 39.4, 95% CI 3.29-470.96). Conclusion The inter-observer agreement on the individual lymph node features as obtained by EUS is moderate with good overall agreement on the diagnosis. Round shape was the feature most strongly associated with a diagnosis of MLN.
引用
收藏
页码:3204 / 3208
页数:5
相关论文
共 18 条
[1]  
Bhutani MS, 2009, J GASTROINTEST LIVER, V18, P181
[2]   A comparison of the accuracy of echo features during endoscopic ultrasound (EUS) and EUS-guided fine-needle aspiration for diagnosis of malignant lymph node invasion [J].
Bhutani, MS ;
Hawes, RH ;
Hoffman, BJ .
GASTROINTESTINAL ENDOSCOPY, 1997, 45 (06) :474-479
[3]   ENDOSONOGRAPHIC FEATURES PREDICTIVE OF LYMPH-NODE METASTASIS [J].
CATALANO, MF ;
SIVAK, MV ;
RICE, T ;
GRAGG, LA ;
VANDAM, J .
GASTROINTESTINAL ENDOSCOPY, 1994, 40 (04) :442-446
[4]   Endoscopic ultrasound-guided fine needle aspiration is superior to lymph node echofeatures: A prospective evaluation of mediastinal and peri-intestinal lymphadenopathy [J].
Chen, VK ;
Eloubeidi, MA .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (04) :628-633
[5]  
DIMAGNO EP, 1980, LANCET, V1, P629
[6]   EUS in patients with benign and malignant lymphadenopathy [J].
Faigel, DO .
GASTROINTESTINAL ENDOSCOPY, 2001, 53 (06) :593-598
[7]   Presence of Lymph Node Vasculature: A New EUS Criterion for Benign Nodes? [J].
Hall, Joshua D. ;
Kahaleh, Michel ;
White, Grace E. ;
Talreja, Jayant ;
Northup, Patrick G. ;
Shami, Vanessa M. .
DIGESTIVE DISEASES AND SCIENCES, 2009, 54 (01) :118-121
[8]   Endosonographic elastography in the diagnosis of mediastinal lymph nodes [J].
Janssen, J. ;
Dietrich, C. F. ;
Will, U. ;
Greiner, L. .
ENDOSCOPY, 2007, 39 (11) :952-957
[9]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]   Prospective Cytological Assessment of Gastrointestinal Luminal Fluid Acquired During EUS: A Potential Source of False-Positive FNA and Needle Tract Seeding [J].
Levy, Michael J. ;
Gleeson, Ferga C. ;
Campion, Michael B. ;
Caudill, Jill L. ;
Clain, Jonathan E. ;
Halling, Kevin ;
Rajan, Elizabeth ;
Topazian, Mark D. ;
Wang, Kenneth K. ;
Wiersema, Maurits J. ;
Clayton, Amy .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (06) :1311-1318