No detectable nephrotoxic side effect using a dimer, non-ionic contrast media in cerebral perfusion computed tomography in case of suspected brain ischemia

被引:7
作者
Petrik, M [1 ]
Weigel, C [1 ]
Kirsch, M [1 ]
Hosten, N [1 ]
机构
[1] Inst Diagnost Radiol & Neuroradiol, D-17487 Greifswald, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2005年 / 177卷 / 09期
关键词
brain infarction; computed tomography; perfusion; iodine and iodine compounds; contrast media induced nephropathy;
D O I
10.1055/s-2005-858318
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In suspected brain ischemia, the perfusion cerebral computed tomography (cCT) should be performed with the lowest amount of contrast media to avoid a contrast media induced nephropathy (CIN) even if the patient already is in renal failure. We were interested to find the best parameters for this examination. Material and Methods: From February 2000 to March 2003, 138 patients (58 females, 80 males, mean age 66.8 years) underwent cCT-perfusion immediately after the admission to our stroke unit. Of these patients, 62% (n = 86) had normal renal function and 38% (n=52) renal failure (up to 381 mu mol/l basic serum creatinine). We varied volume (20-80 ml), flow (5 vs. 7.2 ml/s) and concentration (270 vs. 320 ml/mg iodine) of a dimer, non-ionic contrast media (Visipaque (R)) to establish 5 groups. So we got patients receiving 6 g,12 g,16 g,19 g and 25 g of iodine. After generating the perfusion maps, two radiologists reviewed the quality of the maps and scored it (1-5). We measured the serum creatinine before contrast application and at follow up cCT (days 3 and 7). Results: The quality of the maps increases with increasing amount of iodine. However, the diagnostic result was not significantly better using more than about 16 g of iodine (e. g., 60 ml - 7.2 ml/s - 270 mg/ml) in cCT-perfusion studies. Only one patient had a pathologic increase in serum creatinine (day1: 93; day4: 146 mu mol/l) but died at day 5 because of massive co-morbidity and septic pneumonia. No CIN occurred even in the patient group with pre-existent renal failure. Conclusions: About 60 ml contrast media and a moderate flow rate of about 7 ml/s ensure good results in perfusion-cCT, even if the patients have poor blood circulation or arteriosclerosis. The use of a dimer, non-ionic contrast media (range of 6-25 g iodine) seems to minimize the risk of CIN in the daily routine.
引用
收藏
页码:1242 / 1249
页数:8
相关论文
共 26 条
[1]   Nephrotoxic effects in high-risk patients undergoing angiography. [J].
Aspelin, P ;
Aubry, P ;
Fransson, S ;
Strasser, R ;
Willenbrock, R ;
Berg, KJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (06) :491-499
[2]  
Bohner G, 2003, ROFO-FORTSCHR RONTG, V175, P806
[3]   Comparison of iodixanol and iohexol in renal impairment [J].
Chalmers, N ;
Jackson, RW .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (859) :701-703
[4]   Randomized trial of contrast media utilization in high-risk PTCA - The COURT trial [J].
Davidson, CJ ;
Laskey, WK ;
Hermiller, JB ;
Harrison, JK ;
Matthai, W ;
Vlietstra, RE ;
Brinker, JA ;
Kereiakes, DJ ;
Muhlestein, JB ;
Lansky, A ;
Popma, JJ ;
Buchbinder, M .
CIRCULATION, 2000, 101 (18) :2172-2177
[5]   RADIOCONTRAST NEPHROTOXICITY - A REVIEW [J].
DERAY, G ;
JACOBS, C .
INVESTIGATIVE RADIOLOGY, 1995, 30 (04) :221-225
[6]   Nephrotoxicity of contrast media [J].
Deray, G .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1999, 14 (11) :2602-2606
[7]   Contrast medium induced nephropathy:: pathogenesis, clinical aspects, prophylaxis [J].
Haller, C ;
Kübler, W .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1999, 124 (11) :332-336
[8]   Trial design and reporting standards for intra-arterial cerebral thrombolysis for acute ischemic stroke [J].
Higashida, RT ;
Furlan, AJ .
STROKE, 2003, 34 (08) :E109-E137
[9]  
Keith C J, 2002, Australas Radiol, V46, P221, DOI 10.1046/j.1440-1673.2002.01026.x
[10]   Cerebral perfusion CT -: theoretical aspects, practical implementation and clinical experience in acute ischemic stroke. [J].
König, M ;
Klotz, E ;
Heuser, L .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (03) :210-218