Registration of 3D trans-esophageal echocardiography to X-ray fluoroscopy using image-based probe tracking

被引:72
作者
Gao, Gang [1 ]
Penney, Graeme [1 ]
Ma, Yingliang [1 ]
Gogin, Nicolas [2 ]
Cathier, Pascal [2 ]
Arujuna, Aruna [1 ]
Morton, Geraint [1 ]
Caulfield, Dennis [4 ]
Gill, Jaswinder [4 ]
Rinaldi, C. Aldo [4 ]
Hancock, Jane [4 ]
Redwood, Simon [4 ]
Thomas, Martyn [4 ]
Razavi, Reza [1 ]
Gijsbers, Geert [3 ]
Rhode, Kawal [1 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Philips Healthcare, Medisys Res Grp, Paris, France
[3] Philips Healthcare, Business Program EP, Business Unit iXR, Best, Netherlands
[4] Guys & St Thomas Hosp NHS Fdn Trust, Dept Cardiol, London, England
基金
英国医学研究理事会;
关键词
Image registration; Cardiac intervention; Trans-esophageal echocardiography; X-ray fluoroscopy; CATHETER ABLATION; 3-D ULTRASOUND; CARDIAC-CATHETERIZATION; MR-IMAGES; SYSTEM; INTENSITY; ACCURACY; HEART;
D O I
10.1016/j.media.2011.05.003
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Two-dimensional (2D) X-ray imaging is the dominant imaging modality for cardiac interventions. However, the use of X-ray fluoroscopy alone is inadequate for the guidance of procedures that require soft-tissue information, for example, the treatment of structural heart disease. The recent availability of three-dimensional (3D) trans-esophageal echocardiography (TEE) provides cardiologists with real-time 3D imaging of cardiac anatomy. Increasingly X-ray imaging is now supported by using intra-procedure 3D TEE imaging. We hypothesize that the real-time co-registration and visualization of 3D TEE and Xray fluoroscopy data will provide a powerful guidance tool for cardiologists. In this paper, we propose a novel, robust and efficient method for performing this registration. The major advantage of our method is that it does not rely on any additional tracking hardware and therefore can be deployed straightforwardly into any interventional laboratory. Our method consists of an image-based TEE probe localization algorithm and a calibration procedure. While the calibration needs to be done only once, the GPU-accelerated registration takes approximately from 2 to 15s to complete depending on the number of X-ray images used in the registration and the image resolution. The accuracy of our method was assessed using a realistic heart phantom. The target registration error (TRE) for the heart phantom was less than 2 mm. In addition, we assess the accuracy and the clinical feasibility of our method using five patient datasets, two of which were acquired from cardiac electrophysiology procedures and three from trans-catheter aortic valve implantation procedures. The registration results showed our technique had mean registration errors of 1.5-4.2 mm and 95% capture range of 8.7-11.4 mm in terms of TRE. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:38 / 49
页数:12
相关论文
共 34 条
[1]  
Barker G.H., 2008, AM J CARDIOL, V103, P1025
[2]  
Brost A., 2010, MED IMAGE COMPUTING, P394
[3]   An augmented reality system for patient-specific guidance of cardiac catheter ablation procedures [J].
De Buck, S ;
Maes, F ;
Ector, J ;
Bogaert, J ;
Dymarkowski, S ;
Heidbüchel, H ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (11) :1512-1524
[4]  
Gao G., 2010, INFORM PROCESSING CO
[5]   Real-time Compounding of Three-dimensional Transesophageal Echocardiographic Volumes: the Phantom Study [J].
Gao, Gang ;
Reddy, Kiran ;
Ma, Yingliang ;
Rhode, Kawal S. .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :499-+
[6]   Effect of 3D ultrasound probes on the accuracy of electromagnetic tracking systems [J].
Hastenteufel, Mark ;
Vetter, Marcus ;
Meinzer, Hans-Peter ;
Wolf, Ivo .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (09) :1359-1368
[7]  
Hawkes D.J., 1987, PHYS ENG MED IMAGING, V250, P258
[8]   Intensity-based 2-D-3-D registration of cerebral angiograms [J].
Hipwell, JH ;
Penney, GP ;
McLaughlin, RA ;
Rhode, K ;
Summers, P ;
Cox, TC ;
Byrne, JV ;
Noble, JA ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) :1417-1426
[9]   Rapid Dynamic Image Registration of the Beating Heart for Diagnosis and Surgical Navigation [J].
Huang, Xishi ;
Ren, Jing ;
Guiraudon, Gerard ;
Boughner, Derek ;
Peters, Terry M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) :1802-1814
[10]  
Jain A, 2009, LECT NOTES COMPUT SC, V5528, P321, DOI 10.1007/978-3-642-01932-6_35