Beat-to-beat stroke volume estimation from aortic pressure waveform in conscious rats: comparison of models

被引:12
作者
Cerutti, C [1 ]
Gustin, MP [1 ]
Molino, P [1 ]
Paultre, CZ [1 ]
机构
[1] Fac Pharm Lyon, CNRS, UMR 5014, Dept Physiol & Pharmacol Clin, F-96373 Lyon 08, France
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2001年 / 281卷 / 03期
关键词
cardiac output; hemodynamics; statistical model;
D O I
10.1152/ajpheart.2001.281.3.H1148
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Several methods for estimating stroke volume (SV) were tested in conscious, freely moving rats in which ascending aortic pressure and cardiac flow were simultaneously (beat-to-beat) recorded. We compared two pulse-contour models to two new statistical models including eight parameters extracted from the pressure waveform in a multiple linear regression. Global as well as individual statistical models gave higher correlation coefficients between estimated and measured SV (model 1, r = 0.97; model 2, r = 0.96) than pulse-contour models (model 1, r = 0.83; model 2, r = 0.91). The latter models as well as statistical model 1 used the pulsatile systolic area and thus could be applied to only 47 +/- 17% of the cardiac beats. In contrast, statistical model 2 used the pressure-increase characteristics and was therefore established for all of the cardiac beats. The global statistical model 2 applied to data sets independent of those used to establish the model gave reliable SV estimates: r = 0.54 +/- 0.07, a small bias between -8% to + 10%, and a mean precision of 7%. This work demonstrated the limits of pulse-contour models to estimate SV in conscious, unrestrained rats. A multivariate statistical model using eight parameters easily extracted from the aortic waveform could be applied to all cardiac beats with good precision.
引用
收藏
页码:H1148 / H1155
页数:8
相关论文
共 24 条
[1]   POSSIBILITY OF CARDIAC-OUTPUT MONITORING FROM THE INTRA-ARTERIAL BLOOD-PRESSURE PROFILE [J].
ALICANDRI, C ;
FARIELLO, R ;
BONI, E ;
ZANINELLI, A ;
MUIESAN, G .
CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1985, 7 (2-3) :345-353
[2]   ASSESSMENT OF CARDIAC-OUTPUT FROM NONINVASIVE DETERMINATION OF ARTERIAL-PRESSURE PROFILE IN SUBJECTS AT REST [J].
ANTONUTTO, G ;
GIRARDIS, M ;
TUNIZ, D ;
PETRI, E ;
CAPELLI, C .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1994, 69 (03) :183-188
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function [J].
Gratze, G ;
Fortin, J ;
Holler, A ;
Grasenick, K ;
Pfurtscheller, G ;
Wach, P ;
Schonegger, J ;
Kotanko, P ;
Skrabal, F .
COMPUTERS IN BIOLOGY AND MEDICINE, 1998, 28 (02) :121-142
[5]  
IRIUCHIJIMA J, 1976, JPN HEART J, V17, P80
[6]  
Janssens H.G., 1990, J MICROCOLUMN SEP, V2, P26
[7]   CYCLIC CHANGES IN ARTERIAL PULSE DURING RESPIRATORY SUPPORT [J].
JARDIN, F ;
FARCOT, JC ;
GUERET, P ;
PROST, JF ;
OZIER, Y ;
BOURDARIAS, JP .
CIRCULATION, 1983, 68 (02) :266-274
[8]   ESTIMATION OF STROKE VOLUME IN DOG BY A PULSE CONTOUR METHOD [J].
KOUCHOUKOS, NT ;
SHEPPARD, LC ;
MCDONALD, DA .
CIRCULATION RESEARCH, 1970, 26 (05) :611-+
[9]   Short-term haemodynamic variability in the conscious areflexic rat [J].
Létienne, R ;
Barrès, C ;
Cerutti, C ;
Julien, C .
JOURNAL OF PHYSIOLOGY-LONDON, 1998, 506 (01) :263-274
[10]   Roles of cardiac output and peripheral resistance in mediating blood pressure response to stress in rats [J].
Li, SG ;
Randall, DC ;
Brown, DR .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 1998, 274 (04) :R1065-R1069