Segmental cement extraction system (SEG-CES) and the Ilizarov method in limb salvage procedure after total knee cemented prosthesis removal in a former osteosarcoma patient

被引:13
作者
Ottaviani, G
Randelli, P
Catagni, MA
机构
[1] Univ Milan, Inst Pathol, I-20122 Milan, Italy
[2] Ist Policlin, UO Orthopaed 2, San Donato Milanese, MI, Italy
关键词
segmental cement extraction system; total knee prosthesis; cemented prosthesis removal; metallosis; Ilizarov method; infection;
D O I
10.1007/s00167-004-0575-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Survival of osteosarcoma has greatly improved in the past few decades. Knee prosthesis is a well-recognized limb salvage procedure for osteosarcoma of the distal end of the femur. One drawback is that prostheses have a limited life and prosthetic failure with the inherent high rate of reoperations remains a serious long-term problem for former osteosarcoma patients. The segmental cement extraction system (SEG-CES) is a technique to remove cement in arthroplasty revision, based on a cement-bone interface with a lower strength compared to the old cement-new cement interface. We report the case of a 32-year-old former osteosarcoma patient in whom the SEG-CES was applied to remove a long-stemmed total knee cemented prosthesis. The prosthesis was placed 17 years before for a recurrent telangiectatic osteosarcoma of the left femur. Thirteen years after the prosthesis implantation, the patient complained of knee instability, pain, and complete failure of the extensor apparatus. The extraction of the prosthesis was performed using cylindrical batters of diameter corresponding to the diameter of the axle, two hammer extractors clamping the prosthesis components between two jaws. Extraction of the periprosthetic cement in the femoral and tibial components was done using the SEG-CES technique. The successful prosthesis removal performed in this patient allowed us to perform an external fixation with bone lengthening and reconstruction by the Ilizarov method.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 19 条
[1]   A comparison of prophylactic antibiotic regimens against airborne orthopaedic wound contamination [J].
Brown, AR ;
Vicca, AF ;
Taylor, GJS .
JOURNAL OF HOSPITAL INFECTION, 2001, 48 (02) :117-121
[2]  
CATAGNI MA, 1998, IL QUADRATINO MILAN
[3]  
Cordonnier D, 1996, REV CHIR ORTHOP, V82, P166
[4]  
FALAHEE MH, 1987, J BONE JOINT SURG AM, V60, P790
[5]  
HANSSEN AD, 1995, CLIN ORTHOP RELAT R, P55
[6]  
JAFFE N, 1985, CANCER, V56, P461, DOI 10.1002/1097-0142(19850801)56:3<461::AID-CNCR2820560308>3.0.CO
[7]  
2-L
[8]  
JAFFE N, 1983, CANCER, V51, P402, DOI 10.1002/1097-0142(19830201)51:3<402::AID-CNCR2820510308>3.0.CO
[9]  
2-P
[10]   Knee arthrodesis and limb lengthening in the treatment of infected total knee arthroplasty: Case report [J].
Manzotti, A ;
Pullen, C ;
Guerreschi, F ;
Catagni, MA .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 52 (02) :359-363