Seismic Strengthening of R/C Buildings Retrofitted by New Window-Type System Using Non-Buckling Slit Dampers Examined via Pseudo-Dynamic Testing and Nonlinear Dynamic Analysis

被引:3
作者
Lee, Kang-Seok [1 ]
Lee, Bok-Gi [2 ]
Jung, Ju-Seong [3 ]
机构
[1] Hanyang Univ, Dept Architectural Engn & Smart City Engn, Ansan 15588, South Korea
[2] Hanyang Univ, Dept Architectural Engn, Ansan 15588, South Korea
[3] Hanyang Univ, Innovat Durable Bldg & Infrastruct Res Ctr, Ansan 15588, South Korea
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 03期
基金
新加坡国家研究基金会;
关键词
window-type seismic control system; reinforced concrete; non-buckling slit damper; seismic strengthening; seismic capacity; pseudo-dynamic testing; nonlinear dynamic analysis; REINFORCED-CONCRETE BUILDINGS; PROTECTION; PERFORMANCE; CAPACITY; DESIGN; FRAMES;
D O I
10.3390/app12031220
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present study, a window-type seismic control system (WSCS) using non-buckling slit dampers (NBSDs) was proposed and developed to address the disadvantages of conventional seismic control systems so that it can be effectively applied to existing reinforced concrete (RC) buildings. Materials testing was also conducted to examine the material performance and energy dissipation capacity of NBSD. A full-scale two-story test frame modeled from existing RC buildings with non-seismic details was subjected to pseudo-dynamic testing. As a result, the effect of NBSD-WSCS, when applied to existing RC frames, was examined and verified, especially as to its seismic retrofitting performance. In addition, based on material testing and pseudo-dynamic test results, a restoring force characteristics model was proposed to implement the nonlinear dynamic analysis of a test building retrofitted with NBSD-WSCS. Based on the proposed restoring force characteristics, nonlinear dynamic analysis was conducted, and the results were compared with those obtained by the pseudo-dynamic tests. Finally, in an attempt to commercialize this NBSD-based WSCS, nonlinear dynamic analysis was conducted on the entire RC building with non-seismic details retrofitted with NBSD-WSCS. The results showed that the RC frame (building) with no reinforcement applied underwent shear failure at seismic intensity of 200 cm/s(2), a typical threshold applied in seismic design in Korea. In contrast, in the frame (building) retrofitted with NBSD-WSCS, only minor earthquake damage was expected, and even when the seismic intensity was set to 300 cm/s(2), the maximum intensity that had been observed in Korea, only small or moderate seismic damage was expected. These results confirmed the effectiveness of the seismic retrofitting method using NBSD-WSCS developed in the present study.
引用
收藏
页数:38
相关论文
共 53 条
[1]  
AIK (Architectural Institute of Korea), 2012, DES GUID EX SEISM EN
[2]  
American Society of Civil Engineers, 2010, 7102010 ASCE
[3]  
[Anonymous], 2005, STAND SEISM EV EX RE
[4]  
[Anonymous], 2000, Prestandard and Commentary for the Seismic Rehabilitation of Buildings
[5]  
[Anonymous], 2017, STAND DAM LEV CLASS
[6]  
[Anonymous], 2020, TOKYO SOKI KENKYUJO
[7]  
[Anonymous], 2010, STAND STRUCT CALC RE
[8]  
Architectural Institute of Korea (AIK), 2018, J KOREA CONCR I, V3, P1
[9]   STEEL BRACING OF RC FRAMES FOR SEISMIC RETROFITTING [J].
BADOUX, M ;
JIRSA, JO .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1990, 116 (01) :55-74
[10]   ADAS dampers for the hazard protection of multi-storey buildings with glazing envelopes: a feasibility study [J].
Bedon, C. ;
Amadio, C. .
BOLLETTINO DI GEOFISICA TEORICA ED APPLICATA, 2019, 60 (02) :197-220