Automated Breast Ultrasound vs. Handheld Ultrasound: BI-RADS Classification, Duration of the Examination and Patient Comfort

被引:16
|
作者
Prosch, H. [1 ,3 ]
Halbwachs, C. [2 ]
Strobl, C. [3 ]
Reisner, L. -M. [2 ]
Hondl, M. [2 ]
Weber, M. [1 ]
Mostbeck, G. H. [2 ]
机构
[1] Med Univ Wien, Abt Allgemeine Radiol & Kinderradiol, A-1090 Vienna, Austria
[2] Wilhelminenspital Stadt Wien, Inst Diagnost & Intervent Radiol, Vienna, Austria
[3] Otto Wagner Hosp, Inst Radiodiagnost, Vienna, Austria
来源
ULTRASCHALL IN DER MEDIZIN | 2011年 / 32卷 / 05期
关键词
breast; ultrasound; 3D/4D; MAMMOGRAPHY; CANCER; LESIONS; PERFORMANCE; WOMEN;
D O I
10.1055/s-0031-1273414
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose: Automated breast ultrasound (ABUS) is a potentially valuable adjunct to mammography in breast cancer screening. The reliability and the inter-observer variability in the BI-RADS classification, compared to handheld ultrasound (US), as well as the duration of the examination and patient comfort have only been investigated in a limited number of papers to date. Materials and Methods: In a prospective study, we examined 148 breasts of 76 patients with handheld US and ABUS. The ABUS data were evaluated separately by two investigators. Patient comfort was assessed using a standardized questionnaire. Results: The inter-observer agreement for the BI-RADS classification among the two observers using ABUS was high (K =0,750), the agreement with handheld US was moderate. The sensitivity in the detection of breast cancer was 87.5% for handheld US and 75% for the ABUS evaluation by observer 1. The sensitivity was 87.5% for the ABUS evaluation and 83% for mammography by observer 2. The ABUS examination was rated as completely painless by 64% of the patients. 25% of the patients indicated minor pain, and 10% indicated moderate pain. Handheld US was rated as completely painless by 66% of the patients. 26% of the patients indicated minor pain, and 8% indicated moderate pain. Conclusion: ABUS examinations focusing on the BIRADS classification have low inter-observer variability, compared to handheld US. The sensitivity of ABUS did not differ significantly from handheld US.
引用
收藏
页码:504 / 510
页数:7
相关论文
共 50 条
  • [1] Comparative Analysis of Automated and Handheld Breast Ultrasound Findings for Small (≤1 cm) Breast Cancers Based on BI-RADS Category
    Mun, Han Song
    Ko, Eun Young
    Han, Boo-Kyung
    Ko, Eun Sook
    Choi, Ji Soo
    Kim, Haejung
    Kim, Myoung Kyoung
    Kim, Jieun
    DIAGNOSTICS, 2025, 15 (02)
  • [2] Automated breast ultrasound:: Lesion detection and BI-RADS™ classification -: a pilot study
    Wenkel, E.
    Heckmann, M.
    Heinrich, M.
    Schwab, S. A.
    Uder, M.
    Schulz-Wendtland, R.
    Bautz, W. A.
    Janka, R.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (09): : 804 - 808
  • [3] Diagnostic Performance of Prototype Handheld Ultrasound According to the Fifth Edition of BI-RADS for Breast Ultrasound Compared with Automated Breast Ultrasound among Females with Positive Lumps
    Ibraheem, Shahad A.
    Mahmud, Rozi
    Mohamad Saini, Suraini
    Abu Hassan, Hasyma
    Keiteb, Aysar Sabah
    DIAGNOSTICS, 2023, 13 (06)
  • [4] Quantitative Ultrasound Analysis for Classification of BI-RADS Category 3 Breast Masses
    Moon, Woo Kyung
    Lo, Chung-Ming
    Chang, Jung Min
    Huang, Chiun-Sheng
    Chen, Jeon-Hor
    Chang, Ruey-Feng
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (06) : 1091 - 1098
  • [5] Interobserver concordance in the BI-RADS classification of breast ultrasound exams
    Calas, Maria Julia G.
    Almeida, Renan M. V. R.
    Gutfilen, Bianca
    Pereira, Wagner C. A.
    CLINICS, 2012, 67 (02) : 185 - 189
  • [6] The Potential of Adding Mammography to Handheld Ultrasound or Automated Breast Ultrasound to Reduce Unnecessary Biopsies in BI-RADS Ultrasound Category 4a: A Multicenter Hospital-Based Study in China
    Ren, Wenhui
    Zhao, Xuelian
    Zhao, Xiaowei
    Yan, Huijiao
    Hu, Shangying
    Qiao, Youlin
    Xu, Zhijian
    Zhao, Fanghui
    CURRENT ONCOLOGY, 2023, 30 (03) : 3301 - 3314
  • [7] Dependability of Automated Breast Ultrasound (ABUS) in Assessing Breast Imaging Reporting and Data System (BI-RADS) Category and Size of Malignant Breast Lesions Compared with Handheld Ultrasound (HHUS) and Mammography (MG)
    Chen, He
    Han, Ming
    Jing, Hui
    Liu, Zhao
    Shang, Haitao
    Wang, Qiucheng
    Cheng, Wen
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 9193 - 9202
  • [8] Evaluation of an automated breast volume scanner according to the fifth edition of BI-RADS for breast ultrasound compared with hand-held ultrasound
    Choi, Eun Jung
    Choi, Hyemi
    Park, Eun Hae
    Song, Ji Soo
    Youk, Ji Hyun
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 99 : 138 - 145
  • [9] Prognostic importance of ultrasound BI-RADS classification in breast cancer patients
    Kim, Ju-Yeon
    Jung, Eun Jung
    Park, Taejin
    Jeong, Sang-Ho
    Jeong, Chi-Young
    Ju, Young-Tae
    Lee, Young-Joon
    Hong, Soon-Chan
    Ha, Woo-Song
    Choi, Sang-Kyung
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2015, 45 (05) : 411 - 415
  • [10] The Accuracy of BI-RADS Classification of Breast Ultrasound as a First-Line Imaging Method
    Hille, H.
    Vetter, M.
    Hackeloeer, B. J.
    ULTRASCHALL IN DER MEDIZIN, 2012, 33 (02): : 160 - 163