Assessment of the Possibility of Radiation Dermatitis in the Legs of Interventional Radiologists

被引:1
作者
Zarei, Fariba [1 ]
Zeinali-Rafsanjani, Banafsheh [2 ]
Saeedi-Moghadam, Mahdi [1 ]
Rasekhi, Alireza [1 ]
Foroughi, Amin Abolhasani [1 ]
机构
[1] Shiraz Univ Med Sci, Med Imaging Res Ctr, Shiraz, Iran
[2] Shiraz Univ Med Sci, Nucl Med & Mol Imaging Res Ctr, Shiraz, Iran
关键词
Radiation Dose; Leg; Occupational Dose; Interventional Radiology; SKIN; EXTREMITIES;
D O I
10.5812/iranjradiol.22030
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Fluoroscopy guided imaging, which is going to be more routine these days, requires a long time of fluoroscopic observing that could increase the radiation dose of the physician and other staff who have to stay near the patient during the procedure. In our department, one of the senior interventionists observed hair loss in his lower limb. Objectives: The objective of this study was to measure the radiation dose of the physician's leg during common procedures in order to find out that whether the radiation dose exceeds the threshold of deterministic effects of radiation. Patients and Methods: Thermoluminescent-dosimeters (TLD-100) set on the leg part of the anthropomorphic whole body phantom PBU-50 was used in order to measure the radiation dose in two centers where our interventionist worked. Meanwhile, the duration of exposure in important procedures was observed and recorded in center 1 for 2 months. During this period, data including age, height, and weight of the patients, and radiation exposure time, dose (mGy) and dose area product (dap) (mu Gy.cm(2)) were recorded. Results: The result of TLD dosimetry showed that the mean effective dose in center 1 and 2 was 0.20 and 0.86 mSv, and also the mean-dose (mSv)/min) in these centers was 0.02 +/- 0.00 and 0.20 +/- 0.015 mSv/min, respectively. Conclusion: The effective annual dose of interventionists who work in center 1 and 2 was 143.08 and 1226.78 mSv, respectively. The high radiation dose delivered to the leg of physicians in center 2 could be an important cause of radiation dermatitis occurred on the leg of our interventionist. Patient dose during most of the procedures was less than the threshold dose for occurring erythema. However, unfortunately in transjugular intrahepatic portosystemic shunt (TIPS) procedure, which is a time-consuming procedure, the patient radiation dose exceeds the threshold. It would be useful if a plan was designed to reduce the dose of patients and even physicians.
引用
收藏
页数:4
相关论文
共 20 条
  • [11] DOSES TO OPERATORS DURING INTERVENTIONAL RADIOLOGY PROCEDURES: FOCUS ON EYE LENS AND EXTREMITY DOSIMETRY
    Koukorava, C.
    Carinou, E.
    Simantirakis, G.
    Vrachliotis, T. G.
    Archontakis, E.
    Tierris, C.
    Dimitriou, P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 482 - 486
  • [12] Response of TL materials to diagnostic radiology X radiation beams
    Maia, Ana F.
    Caldas, Linda V. E.
    [J]. APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 780 - 783
  • [13] Clinical Radiation Management for Fluoroscopically Guided Interventional Procedures
    Miller, Donald L.
    Balter, Stephen
    Schueler, Beth A.
    Wagner, Louis K.
    Strauss, Keith J.
    Vano, Eliseo
    [J]. RADIOLOGY, 2010, 257 (02) : 321 - 332
  • [14] SKIN INJURIES IN INTERVENTIONAL PROCEDURES
    Rehani, Madan M.
    Srimahachota, Suphot
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 8 - 12
  • [15] Staff radiation doses to the lower extremities in interventional radiology
    Shortt, C. P.
    Al-Hashimi, H.
    Malone, L.
    Lee, M. J.
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (06) : 1206 - 1209
  • [16] Sina S, 2014, J Biomed Phys Eng, V4, P119
  • [17] The use of extremity dosemeters in a hospital environment
    Vanhavere, F.
    Berus, D.
    Buls, N.
    Covens, P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 118 (02) : 190 - 195
  • [18] Severe skin reactions from interventional fluoroscopy: Case report and review of the literature
    Wagner, LK
    McNeese, MD
    Marx, MV
    Siegel, EL
    [J]. RADIOLOGY, 1999, 213 (03) : 773 - 776
  • [19] Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern?
    Whitby, M
    Martin, CJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (905) : 321 - 327
  • [20] Wiper A, 2005, Heart, V91, P1432, DOI 10.1136/hrt.2005.064899