Simulation of a Predominantly Passive Natural Air Cooling System

被引:0
作者
Venter, P. V. Z. [1 ]
van Eldik, M. [1 ]
机构
[1] North West Univ, POB X6001, ZA-2520 Potchefstroom, South Africa
来源
2018 INTERNATIONAL CONFERENCE ON THE DOMESTIC USE OF ENERGY (DUE) | 2018年
关键词
Air cooling; control volume; earth to air heat exchanger; simulation models; transient cooling;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Climate control is an everyday challenge. With the rapid surge in electricity prices over the past few years, air conditioning operating expenses necessarily increased. The effects, furthermore, of global warming result in increased cooling, and therefore, energy demand. The purpose of this paper is to propose two models that simulate a natural air cooling system. The first model simulates cooling through an earth to air heat exchanger, utilising the soil as a heat sink. The second model simulates the transient cooling of a control volume, which receives cooled air and is open to the environment. A scale model of an earth-to-air heat exchanger system was designed, constructed and used to verify results from the proposed models. Following verification, a real-life size heat exchanger was simulated in order to cool down a room of 60 m(3) within one hour, using only the underground soil as a heat sink. Results showed that a room at an initial 30 degrees C can be cooled down to 20.5 degrees C with a 1.2 m underground heat exchanger and down to 17.8 degrees C if the length is increased to 2.0 m. Only fan power is needed to increase the air's dynamic pressure, resulting in flow conditions. As a result a coefficient of performance between 60 and 80 can be achieved.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 11 条
  • [1] Parametric study on thermal performance of horizontal earth pipe cooling system in summer
    Ahmed, S. F.
    Amanullah, M. T. O.
    Khan, M. M. K.
    Rasul, M. G.
    Hassan, N. M. S.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 114 : 324 - 337
  • [2] Angrisani A., 2015, ENERGY CONVERSION MA, P144
  • [3] [Anonymous], 2005, FUNDAMENTALS HEAT MA, P96
  • [4] Data-Driven Methodology for Energy and Peak Load Reduction of Residential HVAC Systems
    Cetin, Kristen Sara
    Kallus, Catilyn
    [J]. ICSDEC 2016 - INTEGRATING DATA SCIENCE, CONSTRUCTION AND SUSTAINABILITY, 2016, 145 : 852 - 859
  • [5] Ten questions about natural ventilation of.non-domestic buildings
    da Graca, Guilherme Carrilho
    Linden, Paul
    [J]. BUILDING AND ENVIRONMENT, 2016, 107 : 263 - 273
  • [6] Ground heat exchangers - A review of systems, models and applications
    Florides, Georgios
    Kalogirou, Soteris
    [J]. RENEWABLE ENERGY, 2007, 32 (15) : 2461 - 2478
  • [7] Experimental and numerical study of an earth-to-air heat exchanger for air cooling in a residential building in hot semi-arid climate
    Khabbaz, Mohamed
    Benhamou, Brahim
    Limam, Karim
    Hollmuller, Pierre
    Hamdi, Hassan
    Bennouna, Amin
    [J]. ENERGY AND BUILDINGS, 2016, 125 : 109 - 121
  • [8] Application of night cooling concept to social housing design in dry hot climate
    Macias, M.
    Mateo, A.
    Schuler, M.
    Mitre, E. M.
    [J]. ENERGY AND BUILDINGS, 2006, 38 (09) : 1104 - 1110
  • [9] Low cost passive cooling system for social housing in dry hot climate
    Macias, M.
    Gaona, J. A.
    Luxan, J. M.
    Gomez, Gloria
    [J]. ENERGY AND BUILDINGS, 2009, 41 (09) : 915 - 921
  • [10] Design and performance evaluation of low cost Earth to air heat exchanger model suitable for small buildings in arid and semi arid regions
    Misra, Anil Kumar
    Gupta, Mayank
    Lather, Manish
    Garg, Himanshu
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2015, 19 (04) : 853 - 856