Structural characterisation of 1,10-phenanthroline-montmorillonite intercalation compounds and their application as low-cost electrochemical sensors for Pb(II) detection at the sub-nanomolar level

被引:37
作者
Bouwe, Rose G. B. [1 ,3 ,4 ]
Tonle, Ignas K. [1 ,2 ]
Letaief, Sadok [3 ,4 ]
Ngameni, Emmanuel [1 ]
Detellier, Christian [3 ,4 ]
机构
[1] Univ Yaounde I, Fac Sci, Chim Analyt Lab, Yaounde, Cameroon
[2] Univ Dschang, Dept Chim, Lab Chim Minerale, Dschang, Cameroon
[3] Univ Ottawa, Ctr Res & Innovat Catalysis, Ottawa, ON K1N 6N5, Canada
[4] Univ Ottawa, Dept Chem, Ottawa, ON K1N 6N5, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
1,10-Phenanthroline; Intercalation; Organo-clay; Carbon paste electrode; Electrochemical sensor; Lead; SYNTHETIC CLAY-MINERALS; MODIFIED ELECTRODES; POLYPHENOL OXIDASE; CARBON-PASTE; FUNCTIONALIZATION; PRECONCENTRATION; ADSORPTION; KAOLINITE; COMPLEXES; CATIONS;
D O I
10.1016/j.clay.2011.02.028
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A low-cost electrochemical sensor for lead detection was designed and developed in the present study, using an organo-clay obtained by the intercalation of 1,10-phenanthroline (OP) within montmorillonite (MMT). Intercalates of 1,10-phenanthroline in montmorillonite were prepared from a 1/1 water-ethanol aqueous solutions at pHs 3, 5 and 8. Their structural characterisation was done by a variety of spectroscopic and analytical techniques: XRD, FTIR, C-13 and Na-23 NMR, ICP and thermal analysis. Under acidic conditions, OP was protonated and a cation exchange took place with the interlayer sodium ions, leading to a two-dimensional arrangement of protonated OP molecules laying parallel to the clay mineral interlayer surfaces. Under basic conditions, neutral OP was intercalated in the presence of hydrated Na+ ions forming two OP layers plausibly H-bonded to the water molecules coordinating the sodium ions. This latter OP-MMT intercalate was used as Pb(II) sensor via a carbon paste electrode (CPE) by adsorptive stripping voltammetry because it should lead to the exchange of hydrated sodium ions by Pb(II). The amount of accumulated Pb(II) increased with an increase of the accumulation time and remained constant after saturation. The optimal pH of the accumulation medium was 6 and the best electrolysis time and potential were 60 s and -0.8 V respectively. The results obtained in the case of Pb(II) led to a limit of detection in the sub-nanomolar range (4 x 10(-10) M), two orders of magnitude lower than in the case of Cu(II) (4.0 x 10(-8) M). There were no interferences with Cu(II) when it was at concentrations 0.1 x [Pb(II)]. For equimolar concentrations, the Pb(II) signal was reduced by 50%. The interferences were minimal in the case of Ag(I). In contrast, the Pb(II) signal was reduced by 70% in the presence of Hg(II) at concentrations 0.1 x [Pb(II)], showing a strong Hg(II) interference. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 265
页数:8
相关论文
共 39 条
[1]   CARBON PASTE ELECTRODES [J].
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1958, 30 (09) :1576-1576
[2]  
Bergaya F, 2006, DEV CLAY SCI, V1, P1
[3]   HECTORITE COMPLEXES WITH CU(II) AND FE(II)-1,10-PHENANTHROLINE CHELATES [J].
BERKHEISER, VE ;
MORTLAND, MM .
CLAYS AND CLAY MINERALS, 1977, 25 (02) :105-112
[4]   PHOSPHORESCENCE OF O-PHENANTHROLINE [J].
BRINEN, JS ;
HIRT, RC ;
ROSEBROOK, DD .
JOURNAL OF PHYSICAL CHEMISTRY, 1963, 67 (12) :2651-+
[5]   The intercalation reaction of 1,10-phenanthroline with layered compound FePS3 [J].
Chen, XG ;
Yang, CL ;
Qin, JG ;
Yakushi, K ;
Nakazawa, Y ;
Ichimura, K .
JOURNAL OF SOLID STATE CHEMISTRY, 2000, 150 (02) :258-265
[6]   Lead (Pb) isotopic fingerprinting and its applications in lead pollution studies in China: A review [J].
Cheng, Hefa ;
Hu, Yuanan .
ENVIRONMENTAL POLLUTION, 2010, 158 (05) :1134-1146
[7]   CURRENT STATUS OF LEAD-EXPOSURE AND POISONING IN CHILDREN [J].
CHISOLM, JJ .
SOUTHERN MEDICAL JOURNAL, 1976, 69 (05) :529-531
[8]   Characterization of organosilasesquioxane-intercalated-laponite-clay modified electrodes and (bio)electrochemical applications [J].
Coche-Guérente, L ;
Desprez, V ;
Labbé, P .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 458 (1-2) :73-86
[9]   Amplification of amperometric biosensor responses by electrochemical substrate recycling Part II.: Experimental study of the catechol-polyphenol oxidase system immobilized in a laponite clay matrix [J].
Coche-Guérente, L ;
Desprez, V ;
Labbé, P ;
Therias, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 470 (01) :61-69
[10]   Thermodynamic parameters of adsorption of 1,10-phenanthroline and 2,2′-bipyridyl on hematite, kaolinite and montmorillonites [J].
Ferreiro, Eladio A. ;
de Bussetti, Silvia G. .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2007, 301 (1-3) :117-128