Preparation of Iodide Selective Carbon Paste Electrode with Modified Carbon Nanotubes by Potentiometric Method and Effect of CuS-NPs on Its Response

被引:45
作者
Ghaedi, Mehrorang [1 ]
Jaberi, Seyedeh Yasaman Shajaripour [1 ]
Hajati, Shaaker [2 ]
Montazerozohori, Morteza [1 ]
Zarr, Masoumeh [1 ]
Asfaram, Arash [1 ]
Kumawat, Lokesh Kumar [3 ]
Gupta, Vinod Kumar [3 ,4 ]
机构
[1] Univ Yasuj, Dept Chem, Yasuj 7591874831, Iran
[2] Univ Yasuj, Dept Phys, Yasuj 7591874831, Iran
[3] Indian Insit Technol Roorkee, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[4] King Fahd Univ Petr & Minerals Daharan, Ctr water & Environm, Res Inst, Dhahran, Saudi Arabia
关键词
Carbon paste electrode; Potentiometry; Iodide selective electrode; CuS nanoparticles; POLYMERIC MEMBRANE ELECTRODES; PYROLYTIC-GRAPHITE ELECTRODE; POLY(VINYL CHLORIDE) MATRIX; NEUTRAL CARRIERS; ION; SENSOR; RECOGNITION; COMPLEX; PHTHALOCYANINE; NANOPARTICLES;
D O I
10.1002/elan.201400686
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, multiwalled carbon nanotubes (MWCNTs) was oxidized and chemically modified through reaction with 3-(trimethoxysilyl)propan-1-amine (TMSPA) and their subsequent reaction with 2-hydroxy-3-methoxy benzaldehyde. Subsequently, this material was metalized by reaction with copper acetate that lead to formation and impergeation of 2-methoxy-6-((3-(trimethoxysilyl)propylimino)methyl)phenol MMSPIMP-MWCNT-Cu. This novel material was identified with different techniques such as SEM and FT-IR analysis. In this work, the reported material are exhibited high accurate and repeatable monitoring of iodide due to its high surface area with various reactive centre. It exhibited selectivity for iodide over the wide linear dynamic range between 1.8x10(-6) and 1.15x10(-1) M, with a Nernstian slope of -59.12 +/- 0.7 mV per decade of activity and detection limit of 1.8x10(-6) M. Copper sulfide nanoparticles were prepared and their effect on the electrode response was investigated. The results were improved in the presence of nanoparticles with fast and stable response, good reproducibility, long-term stability, high selectivity over the presence of common organic and inorganic anions, high detection limit and dynamic range. The proposed sensor has been applied as potentiometric determination of some iodine species over a pH range of 2.5-10.
引用
收藏
页码:1516 / 1522
页数:7
相关论文
共 36 条
[1]   Iodide selective electrodes based on bis(2-mercaptobenzothiazolato) mercury(II) and bis(4-chlorothiophenolato) mercury(II) carriers [J].
Amini, MK ;
Ghaedi, M ;
Rafi, A ;
Habibi, MH ;
Zohory, MM .
SENSORS, 2003, 3 (11) :509-523
[2]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[3]  
BUINOVSKII AS, 2004, DIAGNOSTIKA MATERIAL, V70, P3
[4]   Bis-dimethylaminobenzaldehyde schiff-base cobalt(II) complex as a neutral carrier for a highly selective iodide electrode [J].
Dai, JY ;
Chai, YQ ;
Yuan, R ;
Zhong, X ;
Liu, Y ;
Tang, DP .
ANALYTICAL SCIENCES, 2004, 20 (12) :1661-1665
[5]  
Downard AJ, 2000, ELECTROANAL, V12, P1085, DOI 10.1002/1521-4109(200010)12:14<1085::AID-ELAN1085>3.0.CO
[6]  
2-A
[7]   Fabrication of a covalently attached multilayer film electrode containing cobalt phthalocyanine and its application as a potentiometric sensor of iodide ion [J].
Fu, YQ ;
Wu, T ;
Li, BS ;
Sun, CQ .
ANALYTICA CHIMICA ACTA, 2002, 455 (01) :61-68
[8]  
Ghaedi M, 2011, INT J ELECTROCHEM SC, V6, P6682
[9]  
Ghaedi M, 2011, INT J ELECTROCHEM SC, V6, P6074
[10]   Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode [J].
Goyal, Rajendra N. ;
Gupta, Vinod K. ;
Chatterjee, Sanghamitra .
TALANTA, 2008, 76 (03) :662-668