Monte Carlo simulation of secondary neutron dose for scanning proton therapy using FLUKA

被引:5
|
作者
Lee, Chaeyeong [1 ]
Lee, Sangmin [2 ]
Lee, Seung-Jae [1 ]
Song, Hankyeol [1 ]
Kim, Dae-Hyun [3 ]
Cho, Sungkoo [3 ]
Jo, Kwanghyun [3 ]
Han, Youngyih [3 ]
Chung, Yong Hyun [1 ]
Kim, Jin Sung [3 ,4 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju, South Korea
[2] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Program Biomed Radiat Sci, Seoul, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiat Oncol, Seoul, South Korea
[4] Yonsei Univ, Coll Med Seoul, Yonsei Canc Ctr, Dept Radiat Oncol, Seoul, South Korea
来源
PLOS ONE | 2017年 / 12卷 / 10期
关键词
CANCER;
D O I
10.1371/journal.pone.0186544
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Proton therapy is a rapidly progressing field for cancer treatment. Globally, many proton therapy facilities are being commissioned or under construction. Secondary neutrons are an important issue during the commissioning process of a proton therapy facility. The purpose of this study is to model and validate scanning nozzles of proton therapy at Samsung Medical Center (SMC) by Monte Carlo simulation for beam commissioning. After the commissioning, a secondary neutron ambient dose from proton scanning nozzle (Gantry 1) was simulated and measured. This simulation was performed to evaluate beam properties such as percent depth dose curve, Bragg peak, and distal fall-off, so that they could be verified with measured data. Using the validated beam nozzle, the secondary neutron ambient dose was simulated and then compared with the measured ambient dose from Gantry 1. We calculated secondary neutron dose at several different points. We demonstrated the validity modeling a proton scanning nozzle system to evaluate various parameters using FLUKA. The measured secondary neutron ambient dose showed a similar tendency with the simulation result. This work will increase the knowledge necessary for the development of radiation safety technology in medical particle accelerators.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Secondary neutron and photon dose in proton therapy
    Agosteo, S
    Birattari, C
    Caravaggio, M
    Silari, M
    Tosi, G
    RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) : 293 - 305
  • [32] A comparison based on the calculation of some hadron doses in addition to the secondary neutron fluence using the FLUKA Monte Carlo code
    Yjjou M.
    Dekhissi H.
    Derkaoui J.E.
    Didi A.
    Aknouch A.
    International Journal of Nuclear Energy Science and Technology, 2020, 14 (04) : 302 - 309
  • [33] Application of Monte Carlo Simulation for Treatment Planning System Commissioning and Dose Calculation for a Pencil Beam Scanning Proton Therapy System
    Hu, H.
    Liu, H.
    Jia, Y.
    Zheng, Y.
    Ding, S.
    Wang, B.
    Li, Y.
    Huang, X.
    Li, Z.
    MEDICAL PHYSICS, 2022, 49 (06) : E860 - E860
  • [34] The Effect of Proton Therapy Beam Scanning Pattern Size On Secondary Neutron Dose Equivalent
    Hecksel, D.
    Anferov, V.
    Shahnazi, K.
    Fitzek, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [35] Monte Carlo simulation of boron neutron capture therapy
    Qiu, YH
    Li, D
    Ying, YJ
    Xiao, G
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 27 (10): : 936 - 942
  • [36] The FLUKA Monte Carlo Code in Ion Beam Therapy
    Rinaldi, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 298 - 298
  • [37] Proton induced radioactivity and neutron yields in tantalum and copper using Monte Carlo simulation
    Biju Keshavkumar
    Vitisha Suman
    D. S. Joshi
    M. S. Kulkarni
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 325 : 869 - 873
  • [38] Proton induced radioactivity and neutron yields in tantalum and copper using Monte Carlo simulation
    Keshavkumar, Biju
    Suman, Vitisha
    Joshi, D. S.
    Kulkarni, M. S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 325 (03) : 869 - 873
  • [39] Streamlined Four-Dimensional CT Dose Calculation Using a GPU-Based Monte Carlo Simulation for Pencil Beam Scanning Proton Therapy
    Shin, J.
    Paganetti, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E483 - E483
  • [40] Systematic Analysis of the Neutron Equivalent Dose in a Mevion S250 Proton Therapy Machine Using Geant4 Monte Carlo Simulation
    Tatari, N.
    Baradaran-Ghahfarokhi, M.
    Roeder, B.
    Zhao, T.
    Khan, R.
    Sobotka, L.
    Darafsheh, A.
    MEDICAL PHYSICS, 2021, 48 (06)