A new device for in situ static and dynamic calibration of force platforms

被引:29
作者
Hsieh, Hong-Jung [2 ,3 ]
Lu, Tung-Wu [1 ]
Chen, Sheng-Chang [1 ]
Chang, Chia-Min [1 ]
Hung, Chinghua [2 ]
机构
[1] Natl Taiwan Univ, Inst Biomed Engn, Taipei, Taiwan
[2] Natl Chiao Tung Univ, Inst Engn Mech, Taipei, Taiwan
[3] Kao Yuan Univ, Dept Mech & Automat Engn, Lujhu, Taiwan
关键词
Motion analysis; Force plate; Calibration; Center of pressure; KNEE OSTEOARTHRITIS; ACCURACY; PLATES; GAIT; PRESSURE; WALKING; POINT; MODEL;
D O I
10.1016/j.gaitpost.2011.03.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In human motion analysis, in situ calibration of the force plate is necessary to improve the accuracy of the measured ground reaction force (GRF) and center of pressure (COP). Few existing devices are capable of both static and dynamic calibration of the usually non-linear GRF and COP errors, while are also easy to move and/or set up without damaging the building. The current study developed a small device (160 cm x 88 cm x 43 cm) with a mass of 50 kg, equipped with auxiliary wheels and fixing suction pads for rapid deployment and easy set-up. A PC-based controller enabled quick movement and accurate positioning of the applied force to the calibration point. Static calibration at 100 validation points and dynamic calibration of a force plate were performed using the device. After correction by an artificial neural network (ANN) trained with the static data from another 121 points, the mean errors for the GRF were all reduced from a maximum of 0.64% to less than 0.01%, while those for the COP were all reduced from a maximum of about 1.37 mm to less than 0.04 mm. For dynamic calibration, the mean errors for the GRF were reduced from a maximum of 0.46% to less than 0.28%, while those for the COP were reduced from a maximum of 0.95 mm to less than 0.11 mm. The results suggest that the calibration device with the ANN method will be useful for obtaining more accurate GRF and COP measurements in human motion analysis. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:701 / 705
页数:5
相关论文
共 22 条
[1]   ACCURACY OF DETERMINING THE POINT OF FORCE APPLICATION WITH PIEZOELECTRIC FORCE PLATES [J].
BOBBERT, MF ;
SCHAMHARDT, HC .
JOURNAL OF BIOMECHANICS, 1990, 23 (07) :705-710
[2]  
BRESLER B, 1950, T AM SOC MECH ENG, V72, P27
[3]   GENERAL COMPUTING METHOD FOR ANALYSIS OF HUMAN LOCOMOTION [J].
CAPPOZZO, A ;
LEO, T ;
PEDOTTI, A .
JOURNAL OF BIOMECHANICS, 1975, 8 (05) :307-320
[4]   Do strain gauge force platforms need in situ correction? [J].
Chockalingam, N ;
Giakas, G ;
Iossifidou, A .
GAIT & POSTURE, 2002, 16 (03) :233-237
[5]   A simple method for calibrating force plates and force treadmills using an instrumented pole [J].
Collins, Steven H. ;
Adamczyk, Peter G. ;
Ferris, Daniel P. ;
Kuo, Arthur D. .
GAIT & POSTURE, 2009, 29 (01) :59-64
[6]   Effects of lateral-wedged insoles on kinetics at the knee [J].
Crenshaw, SJ ;
Pollo, FE ;
Calton, EF .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (375) :185-192
[7]   Forces and energy changes in the leg during walking [J].
Elftman, H .
AMERICAN JOURNAL OF PHYSIOLOGY, 1939, 125 (02) :339-356
[8]   A new testing rig for force platform calibration and accuracy tests [J].
Gill, HS ;
OConnor, JJ .
GAIT & POSTURE, 1997, 5 (03) :228-232
[9]  
GOH JCH, 1993, CLIN ORTHOP RELAT R, P223
[10]   In Situ Calibration and Motion Capture Transformation Optimization Improve Instrumented Treadmill Measurements [J].
Goldberg, Saryn R. ;
Kepple, Thomas M. ;
Stanhope, Steven J. .
JOURNAL OF APPLIED BIOMECHANICS, 2009, 25 (04) :401-406