The Relationship Between Level of Adherence to Automatic Wireless Remote Monitoring and Survival in Pacemaker and Defibrillator Patients

被引:170
作者
Varma, Niraj [1 ]
Piccini, Jonathan P. [2 ]
Snell, Jeffery [3 ]
Fischer, Avi [3 ]
Dalal, Nirav [3 ]
Mittal, Suneet [4 ,5 ]
机构
[1] Cleveland Clin, Inst Heart & Vasc, Cleveland, OH 44195 USA
[2] Duke Univ, Med Ctr, Duke Clin Res Inst, Durham, NC USA
[3] St Jude Med Inc, Div Sci, Sylmar, CA USA
[4] Valley Hlth Syst, Dept Electrophysiol, New York, NY USA
[5] Valley Hlth Syst, Dept Electrophysiol, Ridgewood, NJ USA
关键词
big data; cardiac electronic implantable devices; cardiac resynchronization therapy; device; mortality; survival; time in remote monitoring; DEVICE FOLLOW-UP; CARDIOVERTER-DEFIBRILLATORS; ICD; TRIAL; TIME; CIEDS;
D O I
10.1016/j.jacc.2015.04.033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Remote monitoring (RM) technology embedded within cardiac rhythm devices permits continuous monitoring, which may result in improved patient outcomes. OBJECTIVES This study used "big data" to assess whether RM is associated with improved survival and whether this is influenced by the type of cardiac device and/or its degree of use. METHODS We studied 269,471 consecutive U.S. patients implanted between 2008 and 2011 with pacemakers (PMs), implantable cardioverter-defibrillators (ICDs), or cardiac resynchronization therapy (CRT) with pacing capability (CRT-P)/defibrillation capability (CRT-D) with wireless RM. We analyzed weekly use and all-cause survival for each device type by the percentage of time in RM (% TRM) stratified by age. Socioeconomic influences on % TRM were assessed using 8 census variables from 2012. RESULTS The group had implanted PMs (n = 115,076; 43%), ICDs (n = 85,014; 32%), CRT-D (n = 61,475; 23%), and CRT-P (n = 7,906; 3%). When considered together, 127,706 patients (47%) used RM, of whom 67,920 (53%) had >= 75% TRM (high % TRM) and 59,786 (47%) <75% TRM (low % TRM); 141,765 (53%) never used RM (RM None). RM use was not affected by age or sex, but demonstrated wide geographic and socioeconomic variability. Survival was better in high % TRM versus RM None (hazard ratio [HR]: 2.10; p < 0.001), in high % TRM versus low % TRM (HR: 1.32; p < 0.001), and also in low % TRM versus RM None (HR: 1.58; p < 0.001). The same relationship was observed when assessed by individual device type. CONCLUSIONS RM is associated with improved survival, irrespective of device type (including PMs), but demonstrates a graded relationship with the level of adherence. The results support the increased application of RM to improve patient outcomes. (C) 2015 by the American College of Cardiology Foundation.
引用
收藏
页码:2601 / 2610
页数:10
相关论文
共 24 条
[1]   Use of Remote Monitoring of Newly Implanted Cardioverter-Defibrillators Insights From the Patient Related Determinants of ICD Remote Monitoring (PREDICT RM) Study [J].
Akar, Joseph G. ;
Bao, Haikun ;
Jones, Paul ;
Wang, Yongfei ;
Chaudhry, Sarwat I. ;
Varosy, Paul ;
Masoudi, Frederick A. ;
Stein, Kenneth ;
Saxon, Leslie A. ;
Curtis, Jeptha P. .
CIRCULATION, 2013, 128 (22) :2372-2383
[2]   Follow-up of Patients With New Cardiovascular Implantable Electronic Devices Are Experts' Recommendations Implemented in Routine Clinical Practice? [J].
Al-Khatib, Sana M. ;
Mi, Xiaojuan ;
Wilkoff, Bruce L. ;
Qualls, Laura G. ;
Frazier-Mills, Camille ;
Setoguchi, Soko ;
Hess, Paul L. ;
Curtis, Lesley H. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (01) :108-116
[3]   Remote follow-up and continuous remote monitoring, distinguished [J].
Burri, Haran .
EUROPACE, 2013, 15 :14-16
[4]   Telemonitoring in Patients with Heart Failure [J].
Chaudhry, Sarwat I. ;
Mattera, Jennifer A. ;
Curtis, Jeptha P. ;
Spertus, John A. ;
Herrin, Jeph ;
Lin, Zhenqiu ;
Phillips, Christopher O. ;
Hodshon, Beth V. ;
Cooper, Lawton S. ;
Krumholz, Harlan M. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (24) :2301-2309
[5]   Remote monitoring of cardiovascular devices: a time and activity analysis [J].
Cronin, Edmond M. ;
Ching, Elizabeth A. ;
Varma, Niraj ;
Martin, David O. ;
Wilkoff, Bruce L. ;
Lindsay, Bruce D. .
HEART RHYTHM, 2012, 9 (12) :1947-1951
[6]   The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial The Value of Wireless Remote Monitoring With Automatic Clinician Alerts [J].
Crossley, George H. ;
Boyle, Andrew ;
Vitense, Holly ;
Chang, Yanping ;
Mead, R. Hardwin .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (10) :1181-1189
[7]   Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial [J].
Hindricks, Gerhard ;
Taborsky, Milos ;
Glikson, Michael ;
Heinrich, Ullus ;
Schumacher, Burghard ;
Katz, Amos ;
Brachmann, Johannes ;
Lewalter, Thorsten ;
Goette, Andreas ;
Block, Michael ;
Kautzner, Josef ;
Sack, Stefan ;
Husser, Daniela ;
Piorkowski, Christopher ;
Sogaard, Peter .
LANCET, 2014, 384 (9943) :583-590
[8]   Big Data And New Knowledge In Medicine: The Thinking, Training, And Tools Needed For A Learning Health System [J].
Krumholz, Harlan M. .
HEALTH AFFAIRS, 2014, 33 (07) :1163-1170
[9]   A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial) [J].
Mabo, Philippe ;
Victor, Frederic ;
Bazin, Patrick ;
Ahres, Said ;
Babuty, Dominique ;
Da Costa, Antoine ;
Binet, Didier ;
Daubert, Jean-Claude .
EUROPEAN HEART JOURNAL, 2012, 33 (09) :1105-1111
[10]  
National Institutes of Health Data Science, BIG DAT KNOWL