Pulse oximetry screening for congenital heart defects in newborn infants (PulseOx): a test accuracy study

被引:219
|
作者
Ewer, Andrew K. [1 ,2 ]
Middleton, Lee J. [3 ]
Furmston, Alexandra T.
Bhoyar, Abhay [5 ,6 ]
Daniels, Jane P. [4 ]
Thangaratinam, Shakila [7 ]
Deeks, Jonathan J. [7 ]
Khan, Khalid S. [7 ]
机构
[1] Univ Birmingham, Sch Clin & Expt Med, Birmingham, W Midlands, England
[2] Birmingham Womens Healthcare NHS Fdn Trust, Birmingham, W Midlands, England
[3] Univ Birmingham, Birmingham Clin Trials Unit, Birmingham, W Midlands, England
[4] Birmingham Childrens Hosp NHS Fdn Trust, Birmingham, W Midlands, England
[5] Queen Mary Univ London, Birmingham, W Midlands, England
[6] Barts & London Queen Marys Sch Med & Dent, London, England
[7] Univ Birmingham, Birmingham, W Midlands, England
关键词
FETAL DIAGNOSIS; DISEASE; PREVALENCE; SURVIVAL; IMPACT;
D O I
10.1016/S0140-6736(11)60753-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Screening for congenital heart defects relies on antenatal ultrasonography and postnatal clinical examination; however, life-threatening defects often are not detected. We prospectively assessed the accuracy of pulse oximetry as a screening test for congenital heart defects. Methods In six maternity units in the UK, asymptomatic newborn babies (gestation >34 weeks) were screened with pulse oximetry before discharge. Infants who did not achieve predetermined oxygen saturation thresholds underwent echocardiography. All other infants were followed up to 12 months of age by use of regional and national registries and clinical follow-up. The main outcome was the sensitivity and specificity of pulse oximetry for detection of critical congenital heart defects (causing death or requiring invasive intervention before 28 days) or major congenital heart disease (causing death or requiring invasive intervention within 12 months of age). Findings 20055 newborn babies were screened and 53 had major congenital heart disease (24 critical), a prevalence of 2.6 per 1000 livebirths. Analyses were done on all babies for whom a pulse oximetry reading was obtained. Sensitivity of pulse oximetry was 75.00% (95%. CI 53.29-90.23) for critical cases and 49.06% (35.06-63.16) for all major congenital heart defects. In 35 cases, congenital heart defects were already suspected after antenatal ultrasonography, and exclusion of these reduced the sensitivity to 58.33% (27.67-84.83) for critical cases and 28.57% (14.64-46.30) for all cases of major congenital heart defects. False-positive results were noted for 169 (0.8%) babies (specificity 99.16%, 99.02-99.28), of which six cases were significant, but not major, congenital heart defects, and 40 were other illnesses that required urgent medical intervention. Interpretation Pulse oximetry is a safe, feasible test that adds value to existing screening. It identifies cases of critical congenital heart defects that go undetected with antenatal ultrasonography. The early detection of other diseases is an additional advantage.
引用
收藏
页码:785 / 794
页数:10
相关论文
共 50 条
  • [1] Pulse oximetry as a screening test for congenital heart defects in newborn infants: a test accuracy study with evaluation of acceptability and cost-effectiveness
    Ewer, A. K.
    Furmston, A. T.
    Middleton, L. J.
    Deeks, J. J.
    Daniels, J. P.
    Pattison, H. M.
    Powell, R.
    Roberts, T. E.
    Barton, P.
    Auguste, P.
    Bhoyar, A.
    Thangaratinam, S.
    Tonks, A. M.
    Satodia, P.
    Deshpande, S.
    Kumararatne, B.
    Sivakumar, S.
    Mupanemunda, R.
    Khan, K. S.
    HEALTH TECHNOLOGY ASSESSMENT, 2012, 16 (02) : 1 - +
  • [2] Pulse oximetry screening for congenital heart defects in newborn infants
    Lupo, Ernesto
    ARCHIVOS ARGENTINOS DE PEDIATRIA, 2012, 110 (06): : 463 - 465
  • [3] Review of pulse oximetry screening for critical congenital heart defects in newborn infants
    Ewer, Andrew K.
    CURRENT OPINION IN CARDIOLOGY, 2013, 28 (02) : 92 - 96
  • [4] Pulse oximetry as a screening test for congenital heart defects in newborn infants: a cost-effectiveness analysis
    Roberts, T. E.
    Barton, P. M.
    Auguste, P. E.
    Middleton, L. J.
    Furmston, A. T.
    Ewer, A. K.
    ARCHIVES OF DISEASE IN CHILDHOOD, 2012, 97 (03) : 221 - 226
  • [5] Pulse oximetry screening for critical congenital heart defects in newborn infants: Should it be routine?
    Ewer, Andrew K.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2014, 99 (01): : F93 - U198
  • [7] Pulse oximetry screening for critical congenital heart defects
    Plana, Maria N.
    Zamora, Javier
    Suresh, Gautham
    Fernandez-Pineda, Luis
    Thangaratinam, Shakila
    Ewer, Andrew K.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2018, (03):
  • [8] Pulse Oximetry Screening for Critical Congenital Heart Defects in Newborn Babies
    Girdhar, Anurag
    Ewer, Andrew K.
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2024, 36 (01) : 99 - 110
  • [9] Pulse oximetry screening for critical congenital heart defects in asymptomatic newborn babies: a systematic review and meta-analysis
    Thangaratinam, Shakila
    Brown, Kiritrea
    Zamora, Javier
    Khan, Khalid S.
    Ewer, Andrew K.
    LANCET, 2012, 379 (9835) : 2459 - 2464
  • [10] Pulse oximetry as a screening tool for detecting major congenital heart defects in Indian newborns
    Saxena, Anita
    Mehta, Anurag
    Ramakrishnan, Sivasubramanian
    Sharma, Mamta
    Salhan, Sudha
    Kalaivani, M.
    Juneja, Rajnish
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2015, 100 (05): : F416 - F421