The correctness of fit of current total knee prostheses compared with intra-operative anthropometric measurements in Korean knees

被引:31
作者
Ha, C-W. [1 ]
Na, S-E. [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Orthopaed Surg, Seoul 135710, South Korea
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2012年 / 94B卷 / 05期
关键词
OSTEOARTHRITIC KNEES; ARTHROPLASTY; POPULATION; DESIGN;
D O I
10.1302/0301-620X.94B5.28824
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to report the outcome of 'isolated' anterior cruciate ligament (ACL) ruptures treated with anatomical endoscopic reconstruction using hamstring tendon autograft at a mean of 15 years (14.25 to 16.9). A total of 100 consecutive men and 100 consecutive women with 'isolated' ACL rupture underwent four-strand hamstring tendon reconstruction with anteromedial portal femoral tunnel drilling and interference screw fixation by a single surgeon. Details were recorded pre-operatively and at one, two, seven and 15 years post-operatively. Outcomes included clinical examination, subjective and objective scoring systems, and radiological assessment. At 15 years only eight of 118 patients (7%) had moderate or severe osteo-arthritic changes (International Knee Documentation Committee Grades C and D), and 79 of 152 patients (52%) still performed very strenuous activities. Overall graft survival at 15 years was 83% (1.1% failure per year). Patients aged < 18 years at the time of surgery and patients with > 2 mm of laxity at one year had a threefold increase in the risk of suffering a rupture of the graft (p = 0.002 and p = 0.001, respectively). There was no increase in laxity of the graft over time. ACL reconstructive surgery in patients with an 'isolated' rupture using this technique shows good results 15 years post-operatively with respect to ligamentous stability, objective and subjective outcomes, and does not appear to cause osteoarthritis.
引用
收藏
页码:638 / 641
页数:4
相关论文
共 18 条
[1]  
Bae DK, 2002, J KOREAN ORTHOP ASS, V37, P204
[2]   A new approach of designing the tibial baseplate of total knee prostheses [J].
Cheng, CK ;
Lung, CY ;
Lee, YM ;
Huang, CH .
CLINICAL BIOMECHANICS, 1999, 14 (02) :112-117
[3]   Evaluation of painful total knee arthroplasty [J].
Dennis, DA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (04) :35-40
[4]   Anthropometric measurements of the human knee: Correlation to the sizing of current knee arthroplasty systems [J].
Hitt, K ;
Shurman, JR ;
Greene, K ;
McCarthy, J ;
Moskal, J ;
Hoeman, T ;
Mont, MA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :115-122
[5]   Morphometrical measurements of resected surface of femurs in Chinese knees: Correlation to the sizing of current femoral implants [J].
Ho, WP ;
Cheng, CK ;
Liau, HJ .
KNEE, 2006, 13 (01) :12-14
[6]  
HUANG CH, 2000, J MUSCULOSKELET RES, V4, P39, DOI DOI 10.1142/S0218957700000069
[7]  
Jung YB, 2001, J ORTHOP RES, V4, P10
[8]  
Krackow KA, 1990, TECHNIQUE TOTAL KNEE, P49
[9]   Overhang of the Femoral Component in Total Knee Arthroplasty: Risk Factors and Clinical Consequences [J].
Mahoney, Ormonde M. ;
Kinsey, Tracy .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (05) :1115-1121
[10]  
Matsuda S, 1998, CLIN ORTHOP RELAT R, P183