Deep learning classification of early normal-tension glaucoma and glaucoma suspect eyes using Bruch's membrane opening-based disc photography

被引:2
作者
Seo, Sat Byul [1 ]
Cho, Hyun-kyung [2 ,3 ]
机构
[1] Kyungnam Univ, Sch Educ, Dept Math Educ, Chang Won, South Korea
[2] Gyeongsang Natl Univ, Changwon Hosp, Sch Med, Dept Ophthalmol, Chang Won, South Korea
[3] Gyeongsang Natl Univ, Inst Hlth Sci, Sch Med, Jinju, South Korea
基金
新加坡国家研究基金会;
关键词
Bruch's membrane opening-minimum rim width; Bruch's membrane opening-based disc photography; Bruch's membrane opening overview; deep learning; diagnosis of glaucoma; glaucoma; optical coherence tomography; OPTICAL COHERENCE TOMOGRAPHY; NERVE-FIBER LAYER; MINIMUM RIM WIDTH; GANGLION-CELL COMPLEX; NEURORETINAL RIM; HEAD; FEATURES;
D O I
10.3389/fmed.2022.1037647
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeWe aimed to investigate the performance of a deep learning model to discriminate early normal-tension glaucoma (NTG) from glaucoma suspect (GS) eyes using Bruch's membrane opening (BMO)-based optic disc photography. Methods501 subjects in total were included in this cross-sectional study, including 255 GS eyes and 246 eyes of early NTG patients. BMO-based optic disc photography (BMO overview) was obtained from spectral-domain optical coherence tomography (OCT). The convolutional neural networks (CNN) model built from scratch was used to classify between early NTG and GS. For diagnostic performances of the model, the accuracy and the area under the curve (AUC) of the receiver operating characteristic curve (ROC) were evaluated in the test set. ResultsThe baseline demographics were age, 48.01 +/- 13.03 years in GS, 54.48 +/- 11.28 years in NTG (p = 0.000); mean deviation, -0.73 +/- 2.10 dB in GS, -2.80 +/- 2.40 dB in NTG (p = 0.000); and intraocular pressure, 14.92 +/- 2.62 mmHg in GS, 14.79 +/- 2.61 mmHg in NTG (p = 0.624). Our CNN model showed the mean AUC of 0.94 (0.83-1.00) and the mean accuracy of 0.91 (0.82-0.98) with 10-fold cross validation for discriminating between early NTG and GS. ConclusionThe performance of the CNN model using BMO-based optic disc photography was considerably good in classifying early NTG from GS. This new disc photography of BMO overview can aid in the diagnosis of early glaucoma.
引用
收藏
页数:12
相关论文
共 12 条
  • [1] Deep learning classification of early normal-tension glaucoma and glaucoma suspects using Bruch's membrane opening-minimum rim width and RNFL
    Seo, Sat Byul
    Cho, Hyun-kyung
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [2] The Relationship of the Clinical Disc Margin and Bruch's Membrane Opening in Normal and Glaucoma Subjects
    Amini, Navid
    Miraftabi, Arezoo
    Henry, Sharon
    Chung, Norman
    Nowroozizadeh, Sarah
    Caprioli, Joseph
    Nouri-Mahdavi, Kouros
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (03) : 1468 - 1475
  • [3] Rate of Change in Bruch's Membrane Opening-Minimum Rim Width and Peripapillary RNFL in Early Normal Tension Glaucoma
    Cho, Hyun-kyung
    Kee, Changwon
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 13
  • [4] Dynamics of structural reversal in Bruch's membrane opening-based morphometrics after glaucoma drainage device surgery
    Gietzelt, Caroline
    von Goscinski, Corinna
    Lemke, Julia
    Schaub, Friederike
    Hermann, Manuel M.
    Dietlein, Thomas S.
    Cursiefen, Claus
    Heindl, Ludwig M.
    Enders, Philip
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (06) : 1227 - 1236
  • [5] Impact of ab-interno trabeculectomy on Bruch's membrane opening-based morphometry of the optic nerve head for glaucoma progression analysis
    Kiessling, David
    Christ, Hildegard
    Gietzelt, Caroline
    Schaub, Friederike
    Dietlein, Thomas S.
    Cursiefen, Claus
    Heindl, Ludwig M.
    Enders, Philip
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (02) : 339 - 347
  • [6] Dynamics of structural reversal in Bruch’s membrane opening-based morphometrics after glaucoma drainage device surgery
    Caroline Gietzelt
    Corinna von Goscinski
    Julia Lemke
    Friederike Schaub
    Manuel M. Hermann
    Thomas S. Dietlein
    Claus Cursiefen
    Ludwig M. Heindl
    Philip Enders
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1227 - 1236
  • [7] Impact of ab-interno trabeculectomy on Bruch’s membrane opening-based morphometry of the optic nerve head for glaucoma progression analysis
    David Kiessling
    Hildegard Christ
    Caroline Gietzelt
    Friederike Schaub
    Thomas S. Dietlein
    Claus Cursiefen
    Ludwig M. Heindl
    Philip Enders
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 339 - 347
  • [8] Structural reversal of disc cupping measured in Bruch's membrane opening-based OCT morphometry after PRESERFLO microshunt implantation for open-angle glaucoma
    Lueke, Jan Niklas
    Popp, Constantin
    Gietzelt, Caroline
    Steinberg, Florian
    Lueke, Vincent
    Lappa, Alexandra
    Dietlein, Thomas
    Enders, Philip
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [9] Bruch's membrane opening-based optical coherence tomography of the optic nerve head: a useful diagnostic tool to detect glaucoma in macrodiscs
    Enders, P.
    Schaub, F.
    Adler, W.
    Hermann, M. M.
    Dietlein, T. S.
    Cursiefen, C.
    Heindl, L. M.
    EYE, 2018, 32 (02) : 314 - 323
  • [10] Structure-Function Relationship Between Bruch's Membrane Opening-Based Optic Nerve Head Parameters and Visual Field Defects in Glaucoma
    Muth, Daniel R.
    Hirneiss, Christoph W.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (05) : 3320 - 3328