An initial investigation of the long-term trends in the fluxgate magnetometer (FGM) calibration parameters on the four Cluster spacecraft

被引:10
作者
Alconcel, L. N. S. [1 ]
Fox, P. [1 ]
Brown, P. [1 ]
Oddy, T. M. [1 ]
Lucek, E. L. [1 ]
Carr, C. M. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Phys, Blackett Lab, London SW7 2BW, England
关键词
Magnetometers; -; Orbits; Calibration;
D O I
10.5194/gi-3-95-2014
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Over the course of more than 10 years in operation, the calibration parameters of the outboard fluxgate magnetometer (FGM) sensors on the four Cluster spacecraft are shown to be remarkably stable. The parameters are refined on the ground during the rigorous FGM calibration process performed for the Cluster Active Archive (CAA). Fluctuations in some parameters show some correlation with trends in the sensor temperature (orbit position). The parameters, particularly the offsets, of the spacecraft 1 (C1) sensor have undergone more long-term drift than those of the other spacecraft (C2, C3 and C4) sensors. Some potentially anomalous calibration parameters have been identified and will require further investigation in future. However, the observed long-term stability demonstrated in this initial study gives confidence in the accuracy of the Cluster magnetic field data. For the most sensitive ranges of the FGM instrument, the offset drift is typically 0.2 nT per year in each sensor on C1 and negligible on C2, C3 and C4.
引用
收藏
页码:95 / 109
页数:15
相关论文
共 10 条
[1]   The THEMIS Fluxgate Magnetometer [J].
Auster, H. U. ;
Glassmeier, K. H. ;
Magnes, W. ;
Aydogar, O. ;
Baumjohann, W. ;
Constantinescu, D. ;
Fischer, D. ;
Fornacon, K. H. ;
Georgescu, E. ;
Harvey, P. ;
Hillenmaier, O. ;
Kroth, R. ;
Ludlam, M. ;
Narita, Y. ;
Nakamura, R. ;
Okrafka, K. ;
Plaschke, F. ;
Richter, I. ;
Schwarzl, H. ;
Stoll, B. ;
Valavanoglou, A. ;
Wiedemann, M. .
SPACE SCIENCE REVIEWS, 2008, 141 (1-4) :235-264
[2]   The Cluster magnetic field investigation [J].
Balogh, A ;
Dunlop, MW ;
Cowley, SWH ;
Southwood, DJ ;
Thomlinson, JG ;
Glassmeier, KH ;
Musmann, G ;
Luhr, H ;
Buchert, S ;
Acuna, MH ;
Fairfield, DH ;
Slavin, JA ;
Riedler, W ;
Schwingenschuh, K ;
Kivelson, MG .
SPACE SCIENCE REVIEWS, 1997, 79 (1-2) :65-91
[3]  
Brown P., 2000, FGM INSTRUMENT USERS
[4]  
Escoubet C. P., 1997, CLUSTER PHOENIX MISS
[5]  
GLOAG JM, 2010, FGM DATA PRODUCTS CA, P109
[6]  
Hedgecock P. C., 1975, Space Science Instrumentation, V1, P83
[7]   Accurate determination of magnetic field gradients from four point vector measurements .1. Use of natural constraints on vector data obtained from a single spinning spacecraft [J].
Kepko, EL ;
Khurana, KK ;
Kivelson, MG ;
Elphic, RC ;
Russell, CT .
IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (02) :377-385
[8]  
Laakso H., 2010, ASTROPHYS SPACE SCI
[9]  
Walsh AP, 2010, ASTRON GEOPHYS, V51, P33
[10]   Recalibration of the CHAMP satellite magnetic field measurements [J].
Yin, Fan ;
Luehr, Hermann .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (05)