Identification of temperature variation and vibration disturbance in impedance-based structural health monitoring using piezoelectric sensor array method

被引:23
作者
Bastani, Ali [1 ,2 ]
Amindavar, Hamidreza [1 ]
Shamshirsaz, Mahnaz [2 ]
Sepehry, Naserodin [2 ,3 ]
机构
[1] Amirkabir Univ Technol, Dept Elect Engn, Tehran 1591634311, Iran
[2] Amirkabir Univ Technol, New Technol Res Ctr, Tehran 1591633311, Iran
[3] Amirkabir Univ Technol, Dept Mech Engn, Tehran 1591634311, Iran
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2012年 / 11卷 / 03期
关键词
piezoelectric sensor array; health monitoring; environmental effects; temperature; vibration;
D O I
10.1177/1475921711427486
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Impedance-based structural health monitoring (ISHM) using piezoelectric materials has been extensively developed to provide a structure health indicator. In practice, due to the environmental disturbances, the received signal in different surrounding conditions may be different from intact structure received signal. In the past, any difference was assumed being caused by damage even changes such as temperature effects on the received signal. In ISHM, the received signal is different from the intact structure received signal; however, there is not necessarily damage in the system. So, the validity of ISHM depends on the identification of environmental disturbances in order to extract the real results from disturbed results. In this article, a new method using sensor array and statistical metric analysis has been proposed to identify signal changes derived from damage and/or environmental change. Using this method, it is expected that the environmental variations affect similarly on output signals of different row sensors, whereas changes caused by damage will not be similar for all row and column sensors. This expectation is a general fact because there would be no sensible difference in the environmental variations from one side to other sides of the structure. To identify environmental disturbance from damage detection, an analysis is developed using statistical metrics. Experimental results show that this method is reliable to identify damage.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 28 条
[1]  
Bhalla S, 2003, P INT C SMART MAT ST, P263
[2]  
Cawley P., 1997, STRUCTURAL DAMAGE AS, P1
[3]  
CIOARA TG, 2000, P EUR COST F3 C SYST, P333
[4]   Experimental investigation of E/M impedance health monitoring for spot-welded structural joints [J].
Giurgiutiu, V ;
Reynolds, A ;
Rogers, CA .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 1999, 10 (10) :802-812
[5]  
Giurgiutiu V, 1997, STRUCTURAL HEALT H MONITORING, P433
[6]  
Giurgiutiu V, 2008, STRUCTURAL HEALTH MONITORING: WITH PIEZOELECTRIC WAFER ACTIVE SENSORS, P129, DOI 10.1016/B978-012088760-6.50006-4
[7]  
Helmicki A, 1999, STRUCTURAL HEALTH MONTORING 2000, P408
[8]  
INMAN DJ, 1998, P INT C NOIS VIBR EN, P1
[9]  
KABEYA K, 1998, THESIS VIRGINIA POLY
[10]   Automated Impedance-based Structural Health Monitoring Incorporating Effective Frequency Shift for Compensating Temperature Effects [J].
Koo, Ki-Young ;
Park, Seunghee ;
Lee, Jong-Jae ;
Yun, Chung-Bang .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2009, 20 (04) :367-377