Deep Convolutional Neural Network-Based Hemiplegic Gait Detection Using an Inertial Sensor Located Freely in a Pocket

被引:5
作者
Shin, Hangsik [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Convergence Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
基金
新加坡国家研究基金会;
关键词
accelerometry; convolutional neural network; gait analysis; gyroscope; hemiplegia; inertial signal; RELIABILITY; PARAMETERS;
D O I
10.3390/s22051920
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In most previous studies, the acceleration sensor is attached to a fixed position for gait analysis. However, if it is aimed at daily use, wearing it in a fixed position may cause discomfort. In addition, since an acceleration sensor can be built into the smartphones that people always carry, it is more efficient to use such a sensor rather than wear a separate acceleration sensor. We aimed to distinguish between hemiplegic and normal walking by using the inertial signal measured by means of an acceleration sensor and a gyroscope. We used a machine learning model based on a convolutional neural network to classify hemiplegic gaits and used the acceleration and angular velocity signals obtained from a system freely located in the pocket as inputs without any pre-processing. The classification model structure and hyperparameters were optimized using Bayesian optimization method. We evaluated the performance of the developed model through a clinical trial, which included a walking test of 42 subjects (57.8 +/- 13.8 years old, 165.1 +/- 9.3 cm tall, weighing 66.3 +/- 12.3 kg) including 21 hemiplegic patients. The optimized convolutional neural network model has a convolutional layer, with number of fully connected nodes of 1033, batch size of 77, learning rate of 0.001, and dropout rate of 0.48. The developed model showed an accuracy of 0.78, a precision of 0.80, a recall of 0.80, an area under the receiver operating characteristic curve of 0.80, and an area under the precision-recall curve of 0.84. We confirmed the possibility of distinguishing a hemiplegic gait by applying the convolutional neural network to the signal measured by a six-axis inertial sensor freely located in the pocket without additional pre-processing or feature extraction.
引用
收藏
页数:14
相关论文
共 48 条
  • [11] Gal Y, 2016, PR MACH LEARN RES, V48
  • [12] Abnormal Gait Recognition Algorithm Based on LSTM-CNN Fusion Network
    Gao, Jing
    Gu, Peishang
    Ren, Qing
    Zhang, Jinde
    Song, Xin
    [J]. IEEE ACCESS, 2019, 7 : 163180 - 163190
  • [13] Concurrent validity of a trunk tri-axial accelerometer system for gait analysis in older adults
    Hartmann, Antonia
    Luzi, Susanna
    Murer, Kurt
    de Bie, Rob A.
    de Bruin, Eling D.
    [J]. GAIT & POSTURE, 2009, 29 (03) : 444 - 448
  • [14] Test-retest reliability of trunk accelerometric gait analysis
    Henriksen, M
    Lund, H
    Moe-Nilssen, R
    Bliddal, H
    Danneskiod-Samsoe, B
    [J]. GAIT & POSTURE, 2004, 19 (03) : 288 - 297
  • [15] Thang HM, 2012, INT CONF CONTR AUTO, P344, DOI 10.1109/ICCAIS.2012.6466615
  • [16] Explaining the unique nature of individual gait patterns with deep learning
    Horst, Fabian
    Lapuschkin, Sebastian
    Samek, Wojciech
    Mueller, Klaus-Robert
    Schoellhorn, Wolfgang, I
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [17] Invensense T, MPU 9250 DATASHEET
  • [18] Iso T., 2006, P 8 C HUMAN COMPUTER, P141, DOI [10.1145/1152215.1152244, DOI 10.1145/1152215.1152244]
  • [19] King DB, 2015, ACS SYM SER, V1214, P1
  • [20] CLASSIFICATION OF HUMAN GAIT ACCELERATION DATA USING CONVOLUTIONAL NEURAL NETWORKS
    Kreuter, Daniel
    Takahashi, Hirotaka
    Omae, Yuto
    Akiduki, Takuma
    Zhang, Zhong
    [J]. INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2020, 16 (02): : 609 - 619