Sensitive fluorimetric flow injection analysis for fluoride ion with a novel reagent, 2′,7′-dichlorofluorescein di-tert-butyldimethylsilyl ether

被引:9
作者
Nakaya, Mayu [1 ]
Oshima, Mitsuko [1 ]
Takayanagi, Toshio [1 ]
Motomizu, Shoji [1 ]
Yamashita, Hiroki [1 ]
机构
[1] Okayama Univ, Grad Sch Nat Sci & Technol, Dept Chem, Fac Sci,Kita Ku, Okayama 7008530, Japan
关键词
Fluoride ion; 2; 7 '-dichlorofluorescein-di-tert-butyldimethylsilyl ether; Fluorimetric flow injection analysis; Water; CAPILLARY-ZONE-ELECTROPHORESIS; CONDUCTIVITY DETECTION; AQUEOUS-SOLUTION; CHROMATOGRAPHY; CHLORIDE; COMPLEX; ISOTACHOPHORESIS; PHOSPHATE; DETECTOR; SULFATE;
D O I
10.1016/j.talanta.2011.03.081
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel reagent, 2',7'-dichlorofluorescein di-tert-butyldimethylsilyl ether (FCl2TBS), was synthesized for fluoride ion and used for a sensitive fluorimetric flow injection analysis by detecting the recovery of fluorescence due to cleavage of Si-O bond. Four kinds of fluorescein di-tert-butyldimethylsilyl ether (FTBS) analogues were synthesized and FCl2TBS was the best. By introducing chlorine to FIBS, stability of the reagent, reactivity and the baseline signals were improved. The FIA system was three lines. The sample solution (aqua medium) was injected in the carrier solution (water) and merged with the reagent solution (2.0 x 10(-5) M FCl2TBS acetone solution), then mixed with phosphate buffer solution (pH 7.5). The fluorescence intensities were measured at lambda(ex) 503 nm and lambda(em) 527 nm. The calibration graph had linear relationship between (1.0-50.0) x 10(-6) M and the determinable limit was 1.0 x 10(-6) M. The relative standard deviation of 12 measurements with 1.0 x 10(-6) M F- solution was 1.0% and the sample throughput was 13 h(-1). The developed method was successfully applied to river and tap water samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1361 / 1365
页数:5
相关论文
共 22 条
[1]   Isotachophoresis and isotachophoresis -: zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection [J].
Bodor, R ;
Madajová, V ;
Kaniansky, D ;
Masár, M ;
Jöhnck, M ;
Stanislawski, B .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :155-165
[2]   Determination of total fluorine in blood at trace concentration levels by the Wickbold decomposition method with direct potentiometric detection [J].
Capka, V ;
Bowers, CP ;
Narvesen, JN ;
Rossi, RE .
TALANTA, 2004, 64 (04) :869-878
[3]   A new method for fluoride determination by using fluorophores and dyes anchored onto MCM-41 [J].
Descalzo, AB ;
Jiménez, D ;
El Haskouri, J ;
Beltrán, D ;
Amorós, P ;
Marcos, MD ;
Martínez-Máñez, R ;
Soto, J .
CHEMICAL COMMUNICATIONS, 2002, (06) :562-563
[4]   Colorimetric detection of fluoride in an aqueous solution using Zr(IV)-EDTA complex and a novel hemicyanine dye [J].
Gao, Xia ;
Zheng, Hong ;
Shang, Gui-qin ;
Xu, Jin-Gou .
TALANTA, 2007, 73 (04) :770-775
[5]   Determination of free and total fluoride in rain water using a continuous-flow system equipped with a fluoride ion-selective electrode detector [J].
Hara, H ;
Yabuuchi, K ;
Higashida, M ;
Ogawa, M .
ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) :117-123
[6]  
*JAP WAT WORKS ASS, 2001, STAND METH EX WAT
[7]   DETERMINATION OF CHLORIDE, NITRATE, SULFATE, NITRITE, FLUORIDE, AND PHOSPHATE BY ON LINE COUPLED CAPILLARY ISOTACHOPHORESIS-CAPILLARY ZONE ELECTROPHORESIS WITH CONDUCTIVITY DETECTION [J].
KANIANSKY, D ;
ZELENSKY, I ;
HYBENOVA, A ;
ONUSKA, FI .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4258-4264
[8]   Simultaneous determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate in aqueous solutions at 10-9 to 10-8% level by ion chromatography [J].
Kapinus, EN ;
Revelsky, IA ;
Ulogov, VO ;
Lyalikov, YA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 800 (1-2) :321-323
[9]   Spectrophotometric and complexometric methods for the determination of thorium and fluoride using bromocresol orange reagent [J].
Khalifa, ME ;
Hafez, MAH .
TALANTA, 1998, 47 (03) :547-559
[10]   Chromogenic and fluorescent chemodosimeter for detection of fluoride in aqueous solution [J].
Kim, Soon Young ;
Hong, Jong-In .
ORGANIC LETTERS, 2007, 9 (16) :3109-3112