Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices

被引:104
作者
Pullano, Salvatore Andrea [1 ]
Greco, Marta [1 ]
Bianco, Maria Giovanna [1 ]
Foti, Daniela [2 ]
Brunetti, Antonio [1 ]
Fiorillo, Antonino S. [1 ]
机构
[1] Magna Graecia Univ Catanzaro, Dept Hlth Sci, I-88100 Catanzaro, Italy
[2] Magna Graecia Univ Catanzaro, Dept Expt & Clin Med, I-88100 Catanzaro, Italy
来源
THERANOSTICS | 2022年 / 12卷 / 02期
关键词
assessment of glycemic control; glucose sensors; biological fluids; diabetes technology; point-of-care testing; NEAR-INFRARED SPECTROSCOPY; CONDUCTIVE NI-MOF; BLOOD-GLUCOSE; DIABETES-MELLITUS; RAMAN-SPECTROSCOPY; MONITORING-SYSTEM; TEST STRIPS; SENSORS; TECHNOLOGY; RELIABILITY;
D O I
10.7150/thno.64035
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The demand of glucose monitoring devices and even of updated guidelines for the management of diabetic patients is dramatically increasing due to the progressive rise in the prevalence of diabetes mellitus and the need to prevent its complications. Even though the introduction of the first glucose sensor occurred decades ago, important advances both from the technological and clinical point of view have contributed to a substantial improvement in quality healthcare. This review aims to bring together purely technological and clinical aspects of interest in the field of glucose devices by proposing a roadmap in glucose monitoring and management of patients with diabetes. Also, it prospects other biological fluids to be examined as further options in diabetes care, and suggests, throughout the technology innovation process, future directions to improve the follow-up, treatment, and clinical outcomes of patients.
引用
收藏
页码:493 / 511
页数:19
相关论文
共 187 条
[1]   Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions [J].
Adeel, Muhammad ;
Rahman, Md Mahbubur ;
Caligiuri, Isabella ;
Canzonieri, Vincenzo ;
Rizzolio, Flavio ;
Daniele, Salvatore .
BIOSENSORS & BIOELECTRONICS, 2020, 165
[3]   7. Diabetes Technology: Standards of Medical Care in Diabetes-2021 [J].
不详 .
DIABETES CARE, 2021, 44 :S85-S99
[6]  
[Anonymous], 1995, Z PHYS CHEM
[7]   Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor [J].
Arakawa, Takahiro ;
Kuroki, Yusuke ;
Nitta, Hiroki ;
Chouhan, Prem ;
Toma, Koji ;
Sawada, Shin-ichi ;
Takeuchi, Shuhei ;
Sekita, Toshiaki ;
Akiyoshi, Kazunari ;
Minakuchi, Shunsuke ;
Mitsubayashi, Kohji .
BIOSENSORS & BIOELECTRONICS, 2016, 84 :106-111
[8]   Infrared and Raman spectra, conformational stability, ab initio calculations of structure, and vibrational assignment of α and β glucose [J].
Araujo-Andrade, C ;
Ruiz, F ;
Martínez-Mendoza, JR ;
Terrones, H .
JOURNAL OF MOLECULAR STRUCTURE-THEOCHEM, 2005, 714 (2-3) :143-146
[9]  
Atkinson MA, 2014, LANCET, V383, P69, DOI [10.1016/S0140-6736(13)60591-7, 10.1016/S0140-6736(18)31320-5]
[10]   Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators [J].
Baghelani, Masoud ;
Abbasi, Zahra ;
Daneshmand, Mojgan ;
Light, Peter E. .
SCIENTIFIC REPORTS, 2020, 10 (01)