Parameters Affecting Worst-Case Gradient-Field Heating of Passive Conductive Implants

被引:5
作者
Bassen, Howard [1 ]
Zaidi, Tayeb [1 ]
机构
[1] US FDA, Div Biomed Phys, Ctr Devices & Radiol Hlth, Rockville, MD 20857 USA
关键词
gradient field; heating; hip implant; computational modeling; temperature measurement; MRI safety; METALLIC IMPLANTS; SIMULATION; COILS;
D O I
10.1002/jmri.28321
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Testing MRI gradient-induced heating of implanted medical devices is required by regulatory organizations and others. A gradient heating test of the ISO 10974 Technical Specification (TS) for active implants was adopted for this study of passive hip implants. All but one previous study of hip implants used nonuniform gradient exposure fields in clinical scanners and reported heating of less than 5 degrees C. This present study adapted methods of the TS, addressing the unmet need for identifying worst-case heating via exposures to uniform gradient fields. Purpose To identify gradient-field parameters affecting maximum heating in vitro for a hip implant and a cylindrical titanium disk. Study Type Computational simulations and experimental validation of induced heating. Phantom Tissue-simulating gel. Field Strength 42 T/s RMS, sinusoidal, continuous B fields with high spatial uniformity Assessment Hip implant heating at 1-10 kHz, via computational modeling, validated by limited point measurements. Experimental measurements of exposures of an implant at 42 T/s for 4, 6, and 9 kHz, analyzed at 50, 100, and 150 seconds. Statistical Tests One sample student's t-test to assess difference between computational and experimental results. Experimental vs. computational results were not significantly different (p < 0.05). Results Maximum simulated temperature rise (10-minute exposure) was 10 degrees C at 1 kHz and 0.66 degrees C at 10 kHz. The ratio of the rise for 21 T/s vs. 42 T/s RMS was 4, after stabilizing at 50 seconds (dB/dt ratio squared). Data Conclusions Heating of an implant is proportional to the frequency of the B field and the implant's cross-sectional area and is greater for a thickness on the order of its skin depth. Testing with lower values of dB/dt RMS with lower cost amplifiers enables prediction of heating at higher values for dB/dt squared (per ISO TS) with identical frequency components and waveforms, once thermal equilibrium occurs. Evidence Level 1 Technical Efficacy Stage 1
引用
收藏
页码:1197 / 1204
页数:8
相关论文
共 18 条
[1]   A contribution to MRI safety testing related to gradient-induced heating of medical devices [J].
Arduino, Alessandro ;
Bottauscio, Oriano ;
Chiampi, Mario ;
Zanovello, Umberto ;
Zilberti, Luca .
MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (02) :930-944
[2]   Heating of hip joint implants in MRI: The combined effect of RF and switched-gradient fields [J].
Arduino, Alessandro ;
Zanovello, Umberto ;
Hand, Jeff ;
Zilberti, Luca ;
Bruhl, Rudiger ;
Chiampi, Mario ;
Bottauscio, Oriano .
MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (06) :3447-3462
[3]   In silico evaluation of the thermal stress induced by MRI switched gradient fields in patients with metallic hip implant [J].
Arduino, Alessandro ;
Bottauscio, Oriano ;
Bruehl, Ruediger ;
Chiampi, Mario ;
Zilberti, Luca .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (24)
[4]  
Borio C., 2020, The prudential response to the Covid-19 crisis
[5]   Gradient heating of bulk metallic implants can be a safety concern in MRI [J].
Bruehl, Ruediger ;
Ihlenfeld, Albrecht ;
Ittermann, Bernd .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) :1739-1740
[6]   Heating of metallic rods induced by time-varying gradient fields in MRI [J].
El Bannan, Khaled ;
Handler, William ;
Chronik, Blaine ;
Salisbury, Shaun P. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) :411-416
[7]   Heating of metallic implants and instruments induced by gradient switching in a 1.5-tesla whole-body unit [J].
Graf, Hansjoerg ;
Steidle, Guenter ;
Schick, Fritz .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) :1328-1333
[8]   Magnetic Resonance Imaging: Principles and Techniques: Lessons for Clinicians [J].
Grover, Vijay P. B. ;
Tognarelli, Joshua M. ;
Crossey, Mary M. E. ;
Cox, I. Jane ;
Taylor-Robinson, Simon D. ;
McPhail, Mark J. W. .
JOURNAL OF CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2015, 5 (03) :246-255
[9]   Application and experimental validation of an integral method for simulation of gradient-induced eddy currents on conducting surfaces during magnetic resonance imaging [J].
Harris, C. T. ;
Haw, D. W. ;
Handler, W. B. ;
Chronik, B. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (12) :4367-4379
[10]   Theory of Gradient Coil Design Methods for Magnetic Resonance Imaging [J].
Hidalgo-Tobon, S. S. .
CONCEPTS IN MAGNETIC RESONANCE PART A, 2010, 36A (04) :223-242