A Self-Aligned Method of IMU-Based 3-DoF Lower-Limb Joint Angle Estimation

被引:5
作者
Yi, Chunzhi [1 ]
Wei, Baichun [1 ,2 ]
Ding, Zhen [3 ]
Yang, Chifu [3 ]
Chen, Zhiyuan [4 ]
Jiang, Feng [1 ,2 ]
机构
[1] Harbin Inst Technol, Sch Med & Hlth, Harbin 150001, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Fac Comp, Harbin 150001, Heilongjiang, Peoples R China
[3] Harbin Inst Technol, Sch Mechatron Engn, Harbin 150001, Heilongjiang, Peoples R China
[4] Univ Nottingham Malaysia, Sch Comp Sci, Semenyih 43500, Malaysia
基金
中国国家自然科学基金;
关键词
Kinematics; Calibration; Tracking; Earth; Hip; Estimation; Coordinate measuring machines; Inertial measure unit (IMU); lower-limb joint angle estimation (JAE); three degree-of-freedom (3-DoF) kinematic constraint; TRACKING SYSTEM; RELIABILITY; MOTION; KINECT;
D O I
10.1109/TIM.2022.3194935
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Inertial measurement unit (IMU)-based lower-limb joint angle estimation (JAE) that enables wearable and real-time monitoring of kinematic and biomechanical states has been studied for decades. However, 3-degree-of-freedom (DoF) JAE of lower-limb joints still requires cumbersome calibration procedures. In this article, we propose a self-aligned method by formulating a universal 3-DoF kinematic constraint and solving it by dividing it into three subproblems. Particularly, we divide the issue of optimizing the 3-DoF kinematic constraint by: 1) estimating the main axis following a widely adopted hinge-joint assumption; 2) unifying the reference frames according to a comprehensive metric; and 3) estimating the rest two joint axes. By estimating the coordinates of the three rotational axes of the 3-DoF joint, we further estimate the 3-DoF joint angles by decoupling the joint's rotations into rotations around the axes. We evaluate our method by accuracy comparison with other methods, test-retest reliability, and ablation experiments. The performance demonstrates that the RMSEs of our method are below 2.9 degrees for hip and knee, below 2.6 degrees for ankle, which are comparable with other methods and able to estimate 3-DoF angles in a self-aligned manner. The agreement between test and retest is good, and the ablation experiments demonstrate the effectiveness of sequentially solving the three subproblems. The proposed method is feasible for self-aligned JAE of 3-DoF lower-limb joints. This study may aid the wider application of IMU-based JAE in field conditions and provide a powerful component for wearable human intent decoding.
引用
收藏
页数:10
相关论文
共 36 条
  • [21] Semi-Automatic Sensor-to-Body Calibration of Inertial Sensors on Lower Limb Using Gait Recording
    Nazarahari, Milad
    Rouhani, Hossein
    [J]. IEEE SENSORS JOURNAL, 2019, 19 (24) : 12465 - 12474
  • [22] Paulich M., 2018, XSENS MTW AWINDA MIN, V2018, P1
  • [23] Joint kinematics estimate using wearable inertial and magnetic sensing modules
    Picerno, Pietro
    Cereatti, Andrea
    Cappozzo, Aurelio
    [J]. GAIT & POSTURE, 2008, 28 (04) : 588 - 595
  • [24] On Coordinate-Free Rotation Decomposition: Euler Angles About Arbitrary Axes
    Piovan, Giulia
    Bullo, Francesco
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2012, 28 (03) : 728 - 733
  • [25] IMU-Based Joint Angle Measurement for Gait Analysis
    Seel, Thomas
    Raisch, Joerg
    Schauer, Thomas
    [J]. SENSORS, 2014, 14 (04) : 6891 - 6909
  • [26] Body Topology Recognition and Gait Detection Algorithms With Nine-Axial IMMU
    Shi, Ling-Feng
    Liu, Hong
    Liu, Gong-Xu
    Zheng, Fan
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (03) : 721 - 728
  • [27] Towards Inertial Sensor Based Mobile Gait Analysis: Event-Detection and Spatio-Temporal Parameters
    Teufl, Wolfgang
    Lorenz, Michael
    Miezal, Markus
    Taetz, Bertram
    Froehlich, Michael
    Bleser, Gabriele
    [J]. SENSORS, 2019, 19 (01)
  • [28] Test-retest reliability and minimal clinical change determination for 3-dimensional tibial and femoral accelerations during treadmill walking in knee osteoarthritis patients
    Turcot, Katia
    Aissaoui, Rachid
    Boivin, Karine
    Hagemeister, Nicola
    Pelletier, Michel
    De Guise, Jacques A.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2008, 89 (04): : 732 - 737
  • [29] Vargas L., 2014, Brazilian Congress on Biomedical Engineering - CBEB 2014, P777
  • [30] An IMU-to-Body Alignment Method Applied to Human Gait Analysis
    Vargas-Valencia, Laura Susana
    Elias, Arlindo
    Rocon, Eduardo
    Bastos-Filho, Teodiano
    Frizera, Anselmo
    [J]. SENSORS, 2016, 16 (12):