Bovine liver sample preparation and micro-homogeneity study for Cu and Zn determination by solid sampling electrothermal atomic absorption spectrometry

被引:45
作者
Nomura, CS
Silva, CS
Nogueira, ARA
Oliveira, PV
机构
[1] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, SP, Brazil
[2] Embrapa Pecuaria Sudeste, BR-13560970 Sao Carlos, SP, Brazil
关键词
electrothermal atomic absorption spectrometry; solid sampling; bovine liver; homogeneity; sample preparation;
D O I
10.1016/j.sab.2005.02.021
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This work describes a systematic study for the bovine liver sample preparation for Cu and Zn determination by solid sampling electrothermal. atomic absorption spectrometry. The main parameters investigated were sample drying, grinding process, particle size, sample size, microsample homogeneity, and their relationship with the precision and accuracy of the method. A bovine liver sample was prepared using different drying procedures: (1) freeze drying, and (2) drying in a household microwave oven followed by drying in a stove at 60 degrees C until constant mass. Ball and cryogenic mills were used for grinding. Less sensitive wavelengths for Cu (216.5 nm) and Zn (307.6 nm), and Zeeman-based three-field background correction for Cu were used to diminish the sensitivities. The pyrolysis and atomization temperatures adopted were 1000 degrees C and 23 00 degrees C for Cu, and 700 degrees C and 1700 degrees C for Zn, respectively. For both elements, it was possible to calibrate the spectrometer with aqueous solutions. The use of 250 mu g of W+200 mu g of Rh as permanent chemical modifier was imperative for Zn. Under these conditions, the characteristic mass and detection limit were 1.4 ng and 1.6 ng for Cu, and 2.8 ng and 1.3 ng for Zn, respectively. The results showed good agreement (95% confidence level) for homogeneity of the entire material (> 200 mg) when the sample was dried in microwave/stove and ground in a cryogenic mill. The microsample homogeneity study showed that Zn is more dependent on the sample pretreatment than Cu. The bovine liver sample prepared in microwave/stove and ground in a cryogenic mill presented results with the lowest relative standard deviation for Cu than Zn. Good accuracy and precision were observed for bovine liver masses higher than 40 Vg for Cu and 30 mu g for Zn. The concentrations of Cu and Zn in the prepared bovine liver sample were 223 ing kg(-1) and 128 mg kg(-1), respectively. The relative standard deviations were lower than 6% (n = 5). The accuracy of the entire procedure was checked with bovine liver from NIST (1577b) and determination of Cu and Zn using flame atomic absorption spectrometry after microwave-assisted sample digestion. (c) 2005 Elsevier B.V All rights reserved.
引用
收藏
页码:673 / 680
页数:8
相关论文
共 29 条
[1]   Direct determination of manganese in vitamin-mineral tablets using solid sampling electrothermal atomic absorption spectrometry [J].
Coskun, N ;
Akman, S .
TALANTA, 2004, 64 (02) :496-500
[2]   A solid sampling electrothermal atomic absorption spectrometry method for direct determination of silicon in titanium pieces [J].
Dong, HM ;
Krivan, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (04) :367-371
[3]   Direct solid-sampling electrothermal atomic absorption spectrometry methods for the determination of silicon in oxides of niobium, titanium and zirconium [J].
Dong, HM ;
Krivan, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (09) :1645-1656
[4]   Determination of Al, Cu, Li and Mn in spruce seeds and plant reference materials by slurry sampling graphite furnace atomic absorption spectrometry [J].
Engelsen, C ;
Wibetoe, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (05) :494-503
[5]   A solid-sampling system for a transversely heated graphite furnace and its application to trace element analysis of high-purity tantalum powders by atomic absorption spectrometry [J].
Friese, KC ;
Krivan, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1069-1078
[6]   COMPARISON OF FLAME, ELECTROTHERMAL AND INDUCTIVELY COUPLED PLASMA ATOMIZATION TECHNIQUES FOR THE DIRECT ANALYSIS OF SLURRIES [J].
FULLER, CW ;
HUTTON, RC ;
PRESTON, B .
ANALYST, 1981, 106 (1266) :913-920
[7]   ZEEMAN SS-GFAAS - AN IDEAL METHOD FOR THE EVALUATION OF LEAD AND CADMIUM PROFILES IN BIRDS FEATHERS [J].
HAHN, E ;
HAHN, K ;
MOHL, C ;
STOEPPLER, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (03) :306-309
[8]   Solid sampling electrothermal atomic absorption spectrometry for analysis of high-purity tungsten trioxide and high-purity tungsten blue oxide [J].
Hornung, M ;
Krivan, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (08) :1177-1191
[9]  
Jackson K., 1999, ELECTROTHERMAL ATOMI
[10]   EXPERIMENTS ON DISTRIBUTION AND RAPID-DETERMINATION OF LEAD, CADMIUM AND ZINC IN LIVERS OF SLAUGHTERED PIGS BY SOLID ZEEMAN ATOMIC-ABSORPTION SPECTROMETRY [J].
KLUSSENDORF, B ;
ROSOPULO, A ;
KREUZER, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 322 (07) :721-727