Automated grading for diabetic retinopathy: a large-scale audit using arbitration by clinical experts

被引:72
作者
Fleming, Alan D.
Goatman, Keith A.
Philip, Sam [1 ]
Prescott, Gordon J. [2 ]
Sharp, Peter F.
Olson, John A. [1 ]
机构
[1] NHS Grampian, Diabet Retinal Screening Serv, Aberdeen AB25 2ZP, Scotland
[2] Univ Aberdeen, Sect Populat Hlth, Foresterhill, Scotland
关键词
SCREENING-PROGRAM; COST-EFFECTIVENESS; PHOTOGRAPHY; POPULATION; SCOTLAND; DISEASE;
D O I
10.1136/bjo.2009.176784
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims Automated grading software has the potential to reduce the manual grading workload within diabetic retinopathy screening programmes. This audit was undertaken at the request of Scotland's National Diabetic Retinopathy Screening Collaborative to assess whether the introduction of automated grading software into the national screening programme would be safe, robust and effective. Methods Automated grading, performed by software for image quality assessment and for microaneurysm/dot haemorrhage detection, was carried out on 78 601 images, obtained from 33 535 consecutive patients, which had been manually graded at one of two regional diabetic retinopathy screening programmes. Cases where the automated grading software assessment indicated gradable images with no disease but the screening programme indicated ungradable images or disease more severe than mild retinopathy were arbitrated by seven senior ophthalmologists. Results 100% (180/180) of patients with proliferative retinopathy, 100% (324/324) with referable background retinopathy, 100% (193/193) with observable background retinopathy, 97.3% (1099/1130) with referable maculopathy, 99.2% (384/387) with observable maculopathy and 99.8% (1824/1827) with ungradable images were detected by the software. Conclusion The automated grading software operated to previously published results when applied to a large, unselected population attending two regional screening programmes. Manual grading workload reduction would be 36.3%.
引用
收藏
页码:1606 / 1610
页数:5
相关论文
共 23 条
[1]   Evaluation of a System for Automatic Detection of Diabetic Retinopathy From Color Fundus Photographs in a Large Population of Patients With Diabetes [J].
Abramoff, Michael D. ;
Niemeijer, Meindert ;
Suttorp-Schulten, Maria S. A. ;
Viergever, Max A. ;
Russell, Stephen R. ;
van Ginneken, Bram .
DIABETES CARE, 2008, 31 (02) :193-198
[2]   Long-term impact of retinal screening on significant diabetes-related visual impairment in the working age population [J].
Arun, C. S. ;
Al-Bermani, A. ;
Stannard, K. ;
Taylor, R. .
DIABETIC MEDICINE, 2009, 26 (05) :489-492
[3]  
BritishDiabetic Association, 1997, RET PHOT SCREEN DIAB, P1
[4]   Automated assessment of diabetic retinal image quality based on clarity and field definition [J].
Fleming, AD ;
Philip, S ;
Goatman, KA ;
Olson, JA ;
Sharp, PF .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) :1120-1125
[5]   Automated microaneurysm detection using local contrast normalization and local vessel detection [J].
Fleming, Alan D. ;
Philip, Sam ;
Goatman, Keith A. ;
Olson, John A. ;
Sharp, Peter F. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (09) :1223-1232
[6]   A pilot quality assurance scheme for diabetic retinopathy risk reduction programmes [J].
Garvican, L ;
Scanlon, PH .
DIABETIC MEDICINE, 2004, 21 (10) :1066-1074
[7]   Effectiveness of screening and monitoring tests for diabetic retinopathy - a systematic review [J].
Hutchinson, A ;
McIntosh, A ;
Peters, J ;
O'Keeffe, C ;
Khunti, K ;
Baker, R ;
Booth, A .
DIABETIC MEDICINE, 2000, 17 (07) :495-506
[8]   Cost effectiveness analysis of screening for sight threatening diabetic eye disease [J].
James, M ;
Turner, DA ;
Broadbent, DM ;
Vora, J ;
Harding, SP .
BRITISH MEDICAL JOURNAL, 2000, 320 (7250) :1627-1631
[9]   Automated detection of fundus photographic red lesions in diabetic retinopathy [J].
Larsen, M ;
Godt, J ;
Larsen, N ;
Lund-Andersen, H ;
Sjolie, AK ;
Agardh, E ;
Kalm, H ;
Grunkin, M ;
Owens, DR .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (02) :761-766
[10]   A national retinal screening programme for diabetes in Scotland [J].
Leese, GP ;
Morris, AD ;
Olson, J .
DIABETIC MEDICINE, 2003, 20 (12) :962-964