Functional magnetic resonance imaging using RASER

被引:40
作者
Goerke, Ute [1 ]
Garwood, Michael
Ugurbil, Kamil
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
关键词
Functional magnetic resonance imaging; Orbitofrontal cortex; Susceptibility artifacts; Stroop test; Visual cortex; Ultrahigh magnetic field; ECHO-PLANAR FMRI; BOLD SENSITIVITY LOSSES; INFERIOR FRONTAL-CORTEX; Z-SHIM METHOD; SPIN-ECHO; SIGNAL LOSSES; SUSCEPTIBILITY ARTIFACTS; ORBITOFRONTAL CORTEX; FIELD INHOMOGENEITY; PHYSIOLOGICAL NOISE;
D O I
10.1016/j.neuroimage.2010.08.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Although functional imaging of neuronal activity by magnetic resonance imaging (fMRI) has become the primary methodology employed in studying the brain, significant portions of the brain are inaccessible by this methodology due to its sensitivity to macroscopic magnetic field inhomogeneities induced near air-filled cavities in the head. In this paper, we demonstrate that this sensitivity is eliminated by a novel pulse sequence, RASER (rapid acquisition by sequential excitation and refocusing) (Chamberlain et al., 2007), that can generate functional maps. This is accomplished because RASER acquired signals are purely and perfectly T(2) weighted, without any T(2)*-effects that are inherent in the other image acquisition schemes employed to date. T(2)-weighted fMRI sequences are also more specific to the site of neuronal activity at ultrahigh magnetic fields than T(2)*-variations since they are dominated by signal components originating from the tissue in the capillary bed. The RASER based fMRI response is quantified; it is shown to have an inherently less noisy time series and to provide fMRI in brain regions, such as the orbitofrontal cortex, which are challenging to image with conventional techniques. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:350 / 360
页数:11
相关论文
共 61 条
[1]   Improved BOLD detection in the medial temporal region using parallel imaging and voxel volume reduction [J].
Bellgowan, PSF ;
Bandettini, PA ;
van Gelderen, P ;
Martin, A ;
Bodurka, J .
NEUROIMAGE, 2006, 29 (04) :1244-1251
[2]  
BIRN R, 2002, P INT SOC MAGN RES M, V10, P1324
[3]   Reduction of physiological fluctuations in fMRI using digital filters [J].
Biswal, B ;
DeYoe, EA ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :107-113
[4]  
Bosch V, 2000, J MAGN RESON IMAGING, V11, P61, DOI 10.1002/(SICI)1522-2586(200001)11:1<61::AID-JMRI9>3.0.CO
[5]  
2-C
[6]   IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING [J].
BRUDER, H ;
FISCHER, H ;
REINFELDER, HE ;
SCHMITT, F .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :311-323
[7]  
CHAMBERLAIN R, 2009, P INT SOC MAG RES ME, V17, P2671
[8]   RASER: A new ultrafast magnetic resonance Imaging method [J].
Chamberlain, Ryan ;
Park, Jang-Yeon ;
Corum, Curt ;
Yacoub, Essa ;
Ugurbil, Kamil ;
Jack, Clifford R., Jr. ;
Garwood, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (04) :794-799
[9]  
Chen NK, 2001, MAGNET RESON MED, V45, P525, DOI 10.1002/1522-2594(200103)45:3<525::AID-MRM1070>3.0.CO
[10]  
2-S