Effect of low-intensity pulsed ultrasound on posterolateral lumbar fusion of rabbit

被引:3
作者
Wang, Jian [1 ]
Li, Jian-Wei [1 ]
Chen, Lei [1 ]
机构
[1] Shandong Univ, Rizhao Peoples Hosp Affiliated, Dept Orthoped 3, Rizhao 276826, Peoples R China
关键词
Low-intensily pulsed ultrasound; Lumbar posterolateral; Fusion; Ilium; MODEL;
D O I
10.1016/S1995-7645(14)60190-5
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective: To observe the effect of low-intensity pulsed ultrasound in the posterolateral lumbar fusion of rabbit. Methods: A total of 48 New Zealand white rabbits were randomly divided into the observation group and control group, including the autogenous iliac observation group, artificial bone observation group, artificial bone control group and autogenous iliac control group according to the different bone grafting. The posterolateral lumbar fusion of rabbits in each group was analyzed and compared. Results: After 4 weeks of treatment using the low-intensity pulsed ultrasound, the fusion in the bone grafting area of observation group was good. There was the relatively dense fusion area between the right transverse process and artificial bone. The left transverse process had been completely fused, with the clear bone trabecula through the fusion area. There was no significant fission sign in the control group. According to the fusion comparison between two groups, the fusion rate of the observation group was 83.3% and it was significantly higher than the one of the control group (37.5%). Results of the comparison were statistically significant (P<0.05). The number of chondrocytes and the increase in the relative gray-scale in the fusion area of the iliac observation group were significantly higher than ones of the iliac control group (P<0.05). The number of chondrocytes and the increase in the relative gray-scale in the fusion area of the artificial bone observation group were significantly higher than ones of the artificial bone control group (P<0.05). The expression of IL-1, IL-6 and IL-17 4 weeks after the treatment of the observation group was significantly lower than the one of the control group, with the statistical significance (P<0.05). It indicated that the treatment of low-intensity pulsed ultrasound could reduce the expression level of inflammatory factors. Conclusions: The low-intensity pulsed ultrasound can significantly increase the bone grafting fusion rate of the rabbit's posterolateral lumbar fusion. The possible mechanism is that it promotes the lumbar posterolateral endochondral ossification and reduces the inflammatory reaction.
引用
收藏
页码:68 / 72
页数:5
相关论文
共 50 条
  • [31] EXPERIMENTAL ASSESSMENT OF CALVARIAL BONE DEFECT RE-OSSIFICATION STIMULATION USING LOW-INTENSITY PULSED ULTRASOUND
    Lavandier, Bernard
    Gleizal, Arnaud
    Bera, Jean-Christophe
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (04) : 585 - 594
  • [32] Low-intensity pulsed ultrasound attenuates replacement root resorption of avulsed teeth stored in dry condition in dogs
    Seong, Saemi
    Kim, Dohyun
    Lee, Dasun
    Kim, Hyung-Ryong
    Shin, Yooseok
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [33] Low-Intensity Pulsed Ultrasound Accelerates Tooth Movement via Activation of the BMP-2 Signaling Pathway
    Xue, Hui
    Zheng, Jun
    Cui, Ziping
    Bai, Xiufeng
    Li, Gang
    Zhang, Caidi
    He, Sanhu
    Li, Weihong
    Lajud, Shayanne A.
    Duan, Yinzhong
    Zhou, Hong
    PLOS ONE, 2013, 8 (07):
  • [34] Neuropsychiatric Behavioral Assessments in Mice After Acute and Long-Term Treatments of Low-Intensity Pulsed Ultrasound
    Li, Ye
    Wu, Yiqing
    Luo, Qi
    Ye, Xuanjie
    Chen, Jie
    Su, Yuanlin
    Zhao, Ke
    Li, Xinmin
    Lin, Jing
    Tong, Zhiqian
    Wang, Qi
    Xu, Dongwu
    AMERICAN JOURNAL OF ALZHEIMERS DISEASE AND OTHER DEMENTIAS, 2024, 39
  • [35] Low-Intensity Pulsed Ultrasound Accelerates Traumatic Vertebral Fracture Healing by Coupling Proliferation of Type H Microvessels
    Wu, Suiyi
    Xu, Ximing
    Sun, Jingchuan
    Zhang, Yao
    Shi, Jiangang
    Xu, Tianming
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (07) : 1733 - 1742
  • [36] Low-intensity pulsed ultrasound improves osseointegration of dental implant in mice by inducing local neuronal production of αCGRP
    Jian, Yixuan
    Yuan, Ying
    Xiong, Yi
    Wang, Bin
    Guo, Yanjun
    Gong, Ping
    Zhang, Liang
    ARCHIVES OF ORAL BIOLOGY, 2020, 115
  • [37] Role of low-intensity pulsed ultrasound in regulating macrophage polarization to accelerate tendon-bone interface repair
    Xu, Zihan
    Li, Shengcan
    Wan, Liyang
    Hu, Jianzhong
    Lu, Hongbin
    Zhang, Tao
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (05) : 919 - 929
  • [38] Comparison of Angiogenesis in Bone Defect Healing Process due to the Difference in the Frequency of Low-Intensity Pulsed Ultrasound (LIPUS)
    Sasaki, Hodaka
    Monden, Kazuya
    Yoshinari, Masao
    Yajima, Yasutomo
    JOURNAL OF HARD TISSUE BIOLOGY, 2016, 25 (02) : 157 - 164
  • [39] Low-intensity Pulsed Ultrasound Improves Erectile Function in Streptozotocin-induced Type I Diabetic Rats
    Lei, Hongen
    Xin, Hua
    Guan, Ruili
    Xu, Yongde
    Li, Huixi
    Tian, Wenjie
    Wang, Lin
    Gao, Zhezhu
    Guo, Yinglu
    Lue, Tom F.
    Lin, Guiting
    Xin, Zhongcheng
    UROLOGY, 2015, 86 (06) : 1241.e11 - 1241.e18
  • [40] Low-intensity pulsed ultrasound inhibits VEGFA expression in chondrocytes and protects against cartilage degeneration in experimental osteoarthritis
    Guan, Mengtong
    Zhu, Ying
    Liao, Bo
    Tan, Qiaoyan
    Qi, Huabing
    Zhang, Bin
    Huang, Junlan
    Du, Xiaolan
    Bai, Dingqun
    FEBS OPEN BIO, 2020, 10 (03): : 434 - 443