Effect of maximum coarse aggregate size on dynamic compressive strength of high-strength concrete

被引:67
作者
Kim, Kyoung-Min [1 ]
Lee, Sangho [1 ]
Cho, Jae-Yeol [2 ]
机构
[1] Seoul Natl Univ, Dept Civil & Environm Engn, 35-508,Gwanak Ro 1, Seoul 08826, South Korea
[2] Seoul Natl Univ, Dept Civil & Environm Engn, 35-312,Gwanak Ro 1, Seoul 08826, South Korea
基金
新加坡国家研究基金会;
关键词
Dynamic increase factor; Split Hopkinson pressure bar; Maximum aggregate size; Concrete compressive strength; Standard test method; STRAIN-RATE; MECHANICAL-PROPERTIES; TENSILE BEHAVIOR; PLAIN CONCRETE; ENHANCEMENT; SPECIMEN; MORTAR;
D O I
10.1016/j.ijimpeng.2018.11.003
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Dynamic increase factor (DIF) is a measure of the rate effect in the analysis and design of structures subjected to impact or impulsive loads. A variety of DIFs have been suggested based on the results of split Hopkinson pressure bar (SHPB) tests, which is the test technique most commonly used to obtain dynamic material properties. However, due to the lack of a standard test method and some limitations in the SHPB equipment, most SHPB tests have been conducted for mortar or concrete specimens containing small size coarse aggregate that is very different from the actual concrete used in construction. The DIFs that are provided in most structural design codes are based on these test results. Therefore, it is necessary to investigate the effect of coarse aggregate size on the dynamic concrete compressive strength. In this study, a series of SHPB tests were conducted for mortar and concrete specimens with various maximum aggregate sizes. The test results indicated that the larger maximum coarse aggregate sizes induce larger heterogeneity of specimens. On the other hand, the pure rate DIFs did not exhibit a dependency on the maximum coarse aggregate size. Based on these results, guidance as to the maximum coarse aggregate size of concrete specimens for SHPB tests is provided.
引用
收藏
页码:107 / 116
页数:10
相关论文
共 39 条
[1]   A novel definition of the multivariate coefficient of variation [J].
Albert, Adelin ;
Zhang, Lixin .
BIOMETRICAL JOURNAL, 2010, 52 (05) :667-675
[2]   Study of the mechanical properties of plain concrete under dynamic loading [J].
Albertini, C ;
Cadoni, E ;
Labibes, K .
EXPERIMENTAL MECHANICS, 1999, 39 (02) :137-141
[3]   STUDY OF THE TRUE TENSILE STRESS-STRAIN DIAGRAM OF PLAIN CONCRETE WITH REAL SIZE AGGREGATE - NEED FOR AND DESIGN OF A LARGE HOPKINSON BAR BUNDLE [J].
ALBERTINI, C ;
MONTAGNANI, M .
JOURNAL DE PHYSIQUE IV, 1994, 4 (C8) :113-118
[4]  
Albertini C, 1997, ADVANCES IN FRACTURE RESEARCH, VOLS 1-6, P2987
[5]  
Albertini C, 1993, P 12 INT C STRUCT ME, P55
[6]  
[Anonymous], 2016, C192C192M16A ASTM IN
[7]  
[Anonymous], 2017, C39C39M17B ASTM INT
[8]  
[Anonymous], 2010, SPLIT HOPKINSON KOLS
[9]   DYNAMIC STRENGTH OF POLYMER MODIFIED AND FIBER-REINFORCED CONCRETES [J].
BHARGAVA, J ;
REHNSTROM, A .
CEMENT AND CONCRETE RESEARCH, 1977, 7 (02) :199-208
[10]  
Cadoni E, 2001, ACI MATER J, V98, P220